Impact of miniaturized cardiopulmonary bypass circuits on ultrafiltration during congenital heart surgery

被引:3
|
作者
Wu, Keye
Meng, Baoying
Wang, Yuanxiang
Zhou, Xing
Zhang, Sheshe
Ding, Yiqun
机构
[1] Department of Cardiothoracic Surgery, Shenzhen Children’s Hospital, Shenzhen
来源
PERFUSION-UK | 2021年 / 36卷 / 08期
关键词
cardiopulmonary bypass; ultrafiltration; congenital heart surgery; miniaturized circuit system;
D O I
10.1177/0267659120967206
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To investigate whether the miniaturized cardiopulmonary bypass (CPB) system decreased the usage of ultrafiltration (UF), and to explore whether the non-UF with miniaturized CPB strategy could get good clinical results during congenital heart surgery. Methods: We performed a retrospective analysis of all patients undergoing congenital heart surgery with CPB at Shenzhen Children's Hospital from 1 May 2015 to 30 September 2019. We classified patients to UF with miniaturized CPB group, non-UF with miniaturized CPB group, UF with conventional CPB group and non-UF with conventional CPB group. Results: Of the 2145 patients, 721 (33.6%) were in the conventional CPB group, and 1424 (66.4%) were in the miniaturized CPB group. The UF rate was significantly lower in the miniaturized CPB group compared with that in the conventional CPB group (12.5% vs. 76.8%, p < 0.001). Compared with patients in the other groups, patients in the non-UF with miniaturized CPB group had a shorter postoperative MV time (p < 0.05), and a shorter length of stay in the ICU (p < 0.001) and hospital (p < 0.001). The age of children in the UF with miniaturized CPB group was relatively younger (median: 1.5 months, IQR: 0.3-4.6 months), and the preoperative weight was relatively lower (median: 3.9 kg, IQR: 3.2-5.4 kg). Moreover, this group of children had a relatively longer postoperative MV time and length of stay in the ICU and hospital. Conclusion: The miniaturized CPB system could decrease the usage of UF. Good results were achieved in children who did not use UF based on the miniaturized CPB circuit system during congenital heart surgery.
引用
收藏
页码:832 / 838
页数:7
相关论文
共 50 条
  • [41] Miniaturized cardiopulmonary bypass in adult cardiac surgery: a clinical update
    Dimarakis, Ioannis
    [J]. EXPERT REVIEW OF CARDIOVASCULAR THERAPY, 2016, 14 (11) : 1245 - 1250
  • [42] Renal considerations, dialysis, and ultrafiltration during cardiopulmonary bypass
    Sutton, RG
    [J]. INTERNATIONAL ANESTHESIOLOGY CLINICS, 1996, 34 (02) : 165 - 176
  • [43] Use of ultrafiltration during and after cardiopulmonary bypass in children
    Gaynor, JW
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2001, 122 (02): : 209 - 211
  • [44] Ventricular tachycardia after ultrafiltration during cardiopulmonary bypass
    Terada, Y
    Mitsui, T
    Mihara, W
    Tanaka, M
    [J]. ANNALS OF THORACIC SURGERY, 1997, 63 (04): : 1215 - 1216
  • [45] Modified ultrafiltration after cardiopulmonary bypass in pediatric cardiac surgery
    Draaisma, AM
    Hazekamp, MG
    Frank, M
    Anes, N
    Schoof, PH
    Huysmans, HA
    [J]. ANNALS OF THORACIC SURGERY, 1997, 64 (02): : 521 - 525
  • [46] The impact of heparin-coated circuits on hemodynamics during and after cardiopulmonary bypass
    de Vroege, R
    Huybregts, R
    van Oeveren, W
    van Klarenbosch, J
    Linley, G
    Mutlu, J
    Jansen, E
    Hack, E
    Eijsman, L
    Wildevuur, C
    [J]. ARTIFICIAL ORGANS, 2005, 29 (06) : 490 - 497
  • [47] SUBOPTIMAL HEPARIN USE IN CONGENITAL HEART-DISEASE DURING CARDIOPULMONARY BYPASS
    TURNERGOMES, S
    MITCHELL, L
    MCINTYRE, B
    WILLIAMS, WG
    ANDREW, M
    [J]. THROMBOSIS AND HAEMOSTASIS, 1991, 65 (06) : 1024 - 1024
  • [48] MICROBUBBLE DETECTION DURING CARDIOPULMONARY BYPASS FOR OPEN-HEART SURGERY
    FURNESS, A
    WRIGHT, G
    [J]. LIFE SUPPORT SYSTEMS, 1985, 3 (02): : 103 - 109
  • [49] COMPLEMENT ACTIVATION AND CONSUMPTION DURING CARDIOPULMONARY BYPASS FOR OPEN HEART SURGERY
    王一山
    顾严己
    叶椿秀
    许以平
    张海玲
    [J]. Medical Bulletin of Shanghai Jiaotong University, 1988, (01) : 9 - 13
  • [50] Heparin-coated cardiopulmonary bypass circuits in coronary bypass surgery
    Horimoto, H
    Kondo, K
    Asada, K
    Sasaki, S
    [J]. ARTIFICIAL ORGANS, 1996, 20 (08) : 936 - 940