Image quality is an important component in the evaluation of medical imaging systems and can be measured at a number of points between acquisition and display. However, from the perspective of the clinician, the quality of the image that is presented to the eye-brain system is the most critical since this is what the diagnostic interpretation is derived from. This paper will discuss someways to assess the design and optimization of display systems in reference to the human observer. The paper will include various approaches to study this issue, including Receiver Operating Characteristic studies, modeling of the human-visual system, and the use of eye-position tracking methods. The goal is to demonstrate not only the importance of assessing the impact of display image quality on diagnostic performance, but also on how it can affect workflow and user-comfort levels.
引用
收藏
页码:927 / 932
页数:6
相关论文
共 50 条
  • [21] Novel display image quality analysis based on human visual perception
    Lee, Jongseo
    Souk, Jun H.
    Miseli, Joe
    2007 SID INTERNATIONAL SYMPOSIUM, DIGEST OF TECHNICAL PAPERS, VOL XXXVIII, BOOKS I AND II, 2007, 38 : 414 - +
  • [22] CONTRAST TRANSMISSION IN MEDICAL IMAGE DISPLAY
    PIZER, SM
    ZIMMERMAN, JB
    JOHNSTON, RE
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1982, 375 : 2 - 9
  • [23] Medical Image Display Based on DICOM
    Chen, Peijiang
    MATERIALS ENGINEERING FOR ADVANCED TECHNOLOGIES, PTS 1 AND 2, 2011, 480-481 : 932 - 937
  • [24] Validation of an Image-based Technique to Assess the Perceptual Quality of Clinical Chest Radiographs with an Observer Study
    Lin, Yuan
    Choudhury, Kingshuk R.
    McAdams, H. Page
    Foos, David H.
    Samei, Ehsan
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [25] Implementation of a channelized Hotelling observer model to assess image quality of x-ray angiography systems
    Favazza, Christopher P.
    Fetterly, Kenneth A.
    Hangiandreou, Nicholas J.
    Leng, Shuai
    Schueler, Beth A.
    JOURNAL OF MEDICAL IMAGING, 2015, 2 (01)
  • [26] Image processing of medical radiographs for single image display
    Freedman, M
    Artz, DS
    Mun, SK
    SIXTH INTERNATIONAL CONFERENCE ON IMAGE PROCESSING AND ITS APPLICATIONS, VOL 1, 1997, (443): : 12 - 16
  • [27] CT image quality: Using a model observer for clinically relevant optimisation
    Ryckx, N.
    Racine, D.
    Ba, A.
    Viry, A.
    Bochud, F.
    Verdun, F. R.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S7 - S8
  • [28] Comparison of human observer impression of X-ray fluoroscopy and angiography image quality with technical changes to image quality
    Mihailovic, Jelena M.
    Kanaji, Yoshihisa
    Miller, Daniel
    Bell, Malcolm R.
    Fetterly, Kenneth A.
    JOURNAL OF MEDICAL IMAGING, 2024, 11 (04)
  • [29] Can a channelized Hotelling observer assess image quality in acquired mammographic images of an anthropomorphic breast phantom including image processing?
    Balta, C.
    Bouwman, R. W.
    Sechopoulos, I
    Broeders, M. J. M.
    Karssemeijer, N.
    van Engen, R. E.
    Veldkamp, W. J. H.
    MEDICAL PHYSICS, 2019, 46 (02) : 714 - 725
  • [30] IMAGE QUALITY, THE IDEAL OBSERVER, AND HUMAN-PERFORMANCE OF RADIOLOGIC DECISION TASKS
    BURGESS, A
    ACADEMIC RADIOLOGY, 1995, 2 (06) : 522 - 526