Using the human observer to assess medical image display quality

被引:3
|
作者
Krupinski, Elizabeth A. [1 ]
机构
[1] Univ Arizona, Dept Radiol, Tucson, AZ 85724 USA
关键词
observer performance; ROC; vision models; visual search;
D O I
10.1889/1.2372427
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Image quality is an important component in the evaluation of medical imaging systems and can be measured at a number of points between acquisition and display. However, from the perspective of the clinician, the quality of the image that is presented to the eye-brain system is the most critical since this is what the diagnostic interpretation is derived from. This paper will discuss someways to assess the design and optimization of display systems in reference to the human observer. The paper will include various approaches to study this issue, including Receiver Operating Characteristic studies, modeling of the human-visual system, and the use of eye-position tracking methods. The goal is to demonstrate not only the importance of assessing the impact of display image quality on diagnostic performance, but also on how it can affect workflow and user-comfort levels.
引用
收藏
页码:927 / 932
页数:6
相关论文
共 50 条
  • [1] Learning to Assess Image Quality Like an Observer
    Yao, Xiwen
    Cao, Qinglong
    Feng, Xiaoxu
    Cheng, Gong
    Han, Junwei
    IEEE TRANSACTIONS ON NEURAL NETWORKS AND LEARNING SYSTEMS, 2023, 34 (11) : 8324 - 8336
  • [2] A method to study the image quality of a CRT display using the visual characteristics of the human observer as well as physical measures of the CRT
    Hirata, Y
    Yamane, T
    Tanino, F
    Tanino, S
    Ogawa, T
    Roehrig, H
    RADIOLOGY, 2001, 221 : 153 - 154
  • [3] Using a NPWE model observer to assess suitable image quality for a digital mammography quality assurance programme
    Monnin, P.
    Bochud, F. O.
    Verdun, F. R.
    RADIATION PROTECTION DOSIMETRY, 2010, 139 (1-3) : 459 - 462
  • [4] A virtual image chain for perceived image quality of medical display
    Marchessoux, Cedric
    Jung, J. rgen
    MEDICAL IMAGING 2006: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2006, 6141
  • [5] Human observer confidence in image quality assessment
    Engelke, Ulrich
    Maeder, Anthony
    Zepernick, Hans-Juergen
    SIGNAL PROCESSING-IMAGE COMMUNICATION, 2012, 27 (09) : 935 - 947
  • [6] A Virtual Image Chain for Perceived and Clinical Image Quality of Medical Display
    Marchessoux, Cedric
    Kimpe, Tom
    Bert, Tom
    JOURNAL OF DISPLAY TECHNOLOGY, 2008, 4 (04): : 356 - 368
  • [7] Image Quality Characteristics of Handheld Display Devices for Medical Imaging
    Yamazaki, Asumi
    Liu, Peter
    Cheng, Wei-Chung
    Badano, Aldo
    PLOS ONE, 2013, 8 (11):
  • [8] A MULTI-SLICE MODEL OBSERVER FOR MEDICAL IMAGE QUALITY ASSESSMENT
    Zhang, L.
    Cavaro-Menard, C.
    Le Callet, P.
    Ge, D.
    2015 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING (ICASSP), 2015, : 1667 - 1671
  • [9] Human observer modeling of quantitative image quality in temporally filtered image sequences
    Jabri, KN
    Wilson, DL
    PROCEEDINGS OF THE 19TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 19, PTS 1-6: MAGNIFICENT MILESTONES AND EMERGING OPPORTUNITIES IN MEDICAL ENGINEERING, 1997, 19 : 785 - 787
  • [10] Image quality assessment of monochrome monitors for medical soft copy display
    Weibrecht, M
    Spekowius, G
    Quadflieg, P
    Blume, H
    IMAGE DISPLAY - MEDICAL IMAGING 1997, 1997, 3031 : 232 - 244