A simple, low cost and robust method for measurement of the zero-crossing temperature of an ultralow expansion cavity

被引:8
|
作者
Wang, Chenhao [1 ,2 ]
Ji, Zhonghua [1 ,2 ]
Gong, Ting [1 ,2 ]
Su, Dianqiang [1 ,2 ]
Zhao, Yanting [1 ,2 ]
Xiao, Liantuan [1 ,2 ]
Jia, Suotang [1 ,2 ]
机构
[1] Shanxi Univ, State Key Lab Quantum Opt & Quantum Opt Devices, Inst Laser Spect, Taiyuan 030006, Shanxi, Peoples R China
[2] Shanxi Univ, Collaborat Innovat Ctr Extreme Opt, Taiyuan 030006, Shanxi, Peoples R China
基金
国家重点研发计划;
关键词
zero-crossing temperature; ULE cavity; dual frequency modulation; X 10(-16); FREQUENCY; LASER; CLOCK;
D O I
10.1088/1361-6463/ab36f5
中图分类号
O59 [应用物理学];
学科分类号
摘要
We present a simple, low cost and robust method to measure zero-crossing temperature (ZCT) of an ultralow expansion (ULE) cavity. Low cost fiber electro-optic modulator (EOM) and free space EOM as a frequency bridge and a frequency ruler respectively are used to precisely measure the frequency of cavity mode relative to atom transition which acts as an absolute reference frequency. Neither an expensive optical frequency comb and another ULE cavity-based stabilized laser for reference frequency, nor Pound-Drever-Hall locking system for coupling laser is required, but still allows easily using data acquisition card to record abundant data of cavity mode frequency in short term. Using our presented method, the ZCT fitting error can reach 0.01 degrees C and the total uncertainty can reach 0.22 degrees C, meaning that our presented method is accuracy and reliable.
引用
收藏
页数:6
相关论文
共 39 条
  • [21] Low-cost robust polymer optical fiber temperature sensor based on FIR method for in situ measurement
    Xi'an Institute of Optics and Precision Mechanics of Chinese Academy of Sciences, Xi'an
    710119, China
    不详
    100049, China
    不详
    710069, China
    Guangzi Xuebao, 4
  • [22] A simple and low-cost method for leaf area measurement of detached leaves
    Korva, JT
    Forbes, GA
    EXPERIMENTAL AGRICULTURE, 1997, 33 (01) : 65 - 72
  • [23] A Simple, Robust, and Low-Cost Method To Produce the PURE Cell Free System
    Lavickova, Barbora
    Maerkl, Sebastian J.
    ACS SYNTHETIC BIOLOGY, 2019, 8 (02): : 455 - 462
  • [24] ClearDepth: a simple, robust, and low-cost method to assess root depth in soil
    Rosquete, Michel Ruiz
    Gonzalez, Juan
    Wertz, Kristen
    Gonzalez, Natalie
    Baez, Melissa
    Wang, Lin
    Zhang, Ling
    Patil, Suyash
    Funaro, Lucas
    Busch, Wolfgang
    PLANT JOURNAL, 2025, 121 (01):
  • [25] Fast, Simple, Low-Cost Method Unveils ‘True’ Melt Temperature
    Naitove, Matthew
    1600, Gardner Business Media Inc. (66): : 18 - 19
  • [26] Long-term temperature stabilized measurement of ultra-low expansion Fabry-Perot cavity
    Smid, Radek
    Cizek, Martin
    Buchta, Zdenek
    Lazar, Josef
    Cip, Ondrej
    2012 EUROPEAN FREQUENCY AND TIME FORUM (EFTF), 2012, : 404 - 408
  • [27] Long-term measurement of ultra-low expansion Fabry-Perot cavity in stabilized temperature
    Smid, Radek
    Cizek, Martin
    Buchta, Zdenek
    Lazar, Josef
    Cip, Ondrej
    2012 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM (FCS), 2012,
  • [28] Low-pressure performance of a Fabry-Perot cavity based optical pressure standard working at the zero-thermal-expansion temperature
    Ma, Kun
    Yang, Yuanchao
    Feng, Xiaojuan
    VACUUM, 2024, 221
  • [29] A simple, low cost GC/MS method for the sub-nanogram per litre measurement of organotins in coastal water
    Cole, Russell F.
    Mills, Graham A.
    Bakir, Adil
    Townsend, Ian
    Gravell, Anthony
    Fones, Gary R.
    METHODSX, 2016, 3 : 490 - 496
  • [30] A high-sensitivity, simple, low-cost method for the measurement of time-multiplexed fiber Bragg grating sensors
    Cooper, DJF
    Smith, PWE
    LEOS 2001: 14TH ANNUAL MEETING OF THE IEEE LASERS & ELECTRO-OPTICS SOCIETY, VOLS 1 AND 2, PROCEEDINGS, 2001, : 867 - 868