Indicators for Assessing the Quality of Refractive Error Care

被引:9
|
作者
Lee, Ling [1 ,2 ]
Burnett, Anthea M. [1 ,2 ]
D'Esposito, Fabrizio [3 ]
Fricke, Tim [1 ]
Nguyen, Long Tien [4 ]
Vuong, Duong Anh [5 ]
Nguyen, Hien Thi Thu [6 ]
Yu, Mitasha [1 ]
Nguyen, Ngoc Viet My [4 ]
Huynh, Ly Phuong [7 ]
Ho, Suit May [1 ,3 ]
机构
[1] Brien Holden Vis Inst, Sydney, NSW, Australia
[2] Univ New South Wales, Sch Optometry & Vis Sci, Sydney, NSW, Australia
[3] Fred Hollows Fdn, Melbourne, Vic, Australia
[4] Fred Hollows Fdn Vietnam, Da Nang, Vietnam
[5] Minist Hlth, Med Serv Adm, Hanoi, Vietnam
[6] Vietnam Natl Inst Ophthalmol, Hanoi, Vietnam
[7] Brien Holden Vis Inst, Hanoi, Vietnam
关键词
The Fred Hollows Foundation;
D O I
10.1097/OPX.0000000000001629
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
SIGNIFICANCE Quality refractive error care is essential for reducing vision impairment. Quality indicators and standardized approaches for assessing the quality of refractive error care need to be established. PURPOSE This study aimed to develop a set of indicators for assessing the quality of refractive error care and test their applicability in a real-world setting using unannounced standardized patients (USPs). METHODS Patient outcomes and three quality of refractive error care (Q.REC) indicators (1, optimally prescribed spectacles; 2, adequately prescribed spectacles; 3, vector dioptric distance) were developed using existing literature, refraction training standards, and consulting educators. Twenty-one USPs with various refractive errors were trained to visit optical stores across Vietnam to have a refraction, observe techniques, and order spectacles. Spectacles were assessed against each Q.REC indicator and tested for associations with vision and comfort. RESULTS Overall, 44.1% (184/417) of spectacles provided good vision and comfort. Of the spectacles that met Q.REC indicators 1 and 2, 62.5 and 54.9%, respectively, provided both good vision and comfort. Optimally prescribed spectacles (indicator 1) were significantly more likely to provide good vision and comfort independently compared with spectacles that did not meet any indicator (good vision: 94.6 vs. 85.0%, P = .01; comfortable: 66.1 vs. 36.3%, P < .01). Adequately prescribed spectacles (indicator 2) were more likely to provide good comfort compared with spectacles not meeting any indicator (57.7 vs. 36.3%, P < .01); however, vision outcomes were not significantly different (85.9 vs. 85.0%, P = .90). Good vision was associated with a lower mean vector dioptric distance (P < .01) but not with comfort (P = .52). CONCLUSIONS The optimally prescribed spectacles indicator is a promising approach for assessing the quality of refractive error care without additional assessments of vision and comfort. Using USPs is a practical approach and could be used as a standardized method for evaluating the quality of refractive error care.
引用
收藏
页码:24 / 31
页数:8
相关论文
共 50 条
  • [21] Developing quality indicators for assessing quality of birth centre care: a mixed- methods study
    Inge C. Boesveld
    Marieke A. A. Hermus
    Hanneke J. de Graaf
    Marit Hitzert
    Karin M. van der Pal-de Bruin
    Raymond G. de Vries
    Arie Franx
    Therese A. Wiegers
    BMC Pregnancy and Childbirth, 17
  • [22] Developing quality indicators for assessing quality of birth centre care: a mixed- methods study
    Boesveld, Inge C.
    Hermus, Marieke A. A.
    de Graaf, Hanneke J.
    Hitzert, Marit
    van der Pal-de Bruin, Karin M.
    de Vries, Raymond G.
    Franx, Arie
    Wiegers, Therese A.
    BMC PREGNANCY AND CHILDBIRTH, 2017, 17
  • [23] Assessing outcomes following surgery for colorectal cancer using quality of care indicators
    Vergara-Fernandez, Omar
    Swallow, Carol J.
    Victor, J. Charles
    O'Connor, Brenda I.
    Gryphe, Robert
    MacRae, Helen M.
    Zohen, Zane
    McLeod, Robin S.
    CANADIAN JOURNAL OF SURGERY, 2010, 53 (04) : 232 - 240
  • [24] Evaluation of Structure Indicators for Assessing Skin Cancer Quality of Care in Dermatology Departments
    Kueder-Pajares, T.
    Descalzo, M. A.
    Garcia-Doval, I
    Rios-Buceta, L.
    Moreno-Ramirez, D.
    ACTAS DERMO-SIFILIOGRAFICAS, 2018, 109 (09): : 807 - 812
  • [25] Assessing quality of care - Administrative indicators and clinical outcomes in posttraumatic stress disorder
    Rosenheck, R
    Fontana, A
    Stolar, M
    MEDICAL CARE, 1999, 37 (02) : 180 - 188
  • [26] INDICATORS FOR ASSESSING THE QUALITY OF PALLIATIVE AND END-OF-LIFE CARE FOR CHILDREN WITH CANCER
    Duc, J. K.
    Widger, K. A.
    Bouffet, E.
    Friedrichsdorf, S.
    Greenberg, M.
    Husain, A.
    Liben, S.
    Pole, J. D.
    Siden, H.
    Whitlock, J.
    Wolfe, J.
    Rapoport, A.
    PEDIATRIC BLOOD & CANCER, 2014, 61 : S391 - S391
  • [27] PROCESS INDICATORS FOR ASSESSING QUALITY OF HOSPITALS CARE: A CASE STUDY ON STEMI PATIENTS
    Ieva, Francesca
    Paganoni, Anna Maria
    JP JOURNAL OF BIOSTATISTICS, 2011, 6 (01) : 53 - 75
  • [28] Refractive error and vision related quality of life
    Rajabpour, Mojtaba
    Kangari, Haleh
    Pesudovs, Konrad
    Khorrami-nejad, Masoud
    Rahmani, Saeed
    Mohaghegh, Sahar
    Moradnejad, Shima
    BMC OPHTHALMOLOGY, 2024, 24 (01)
  • [29] Refractive error and vision related quality of life
    Mojtaba Rajabpour
    Haleh Kangari
    Konrad Pesudovs
    Masoud Khorrami-nejad
    Saeed Rahmani
    Sahar Mohaghegh
    Shima Moradnejad
    BMC Ophthalmology, 24
  • [30] Update on Eye Care - Amblyopia and Refractive Error
    Joachimsen, Lutz
    Gross, Nikolai J.
    Lagreze, Wolf A.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2018, 235 (08) : 945 - 954