Unwrapping phase in 3D MR phase contrast angiograms

被引:0
|
作者
Bhalerao, A
Westin, CF
Kikinis, R
机构
关键词
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
The phase of a MR signal can provide important information about magnetic field inhomogeneity, or be used to map the velocity of blood flow. However, phase images can contain artifacts due to phase wrapping when the imaged signal lies outside the 2 pi range (i.e. outside the velocity encoding range for PCA) and is wrapped back on itself. For example, in 3D PCA sequences it might be necessary to deliberately reduce the encoding range to better discern small or slow flowing vessels causing aliasing in higher velocity regions. In this paper we show that we can quickly and reliably correct for such artifacts and gain a factor of two in the imaged dynamic range. Using an automatic filtering based method, we derive a statement of the certainty of the phase signal at each point to control an iterative decision process. This algorithm does not require the user to supply a threshold and is non-causal in the sense that it does not rely on finding good regions which is a drawback of methods reported elsewhere. After a detailed description of our algorithm, we present results of phase unwrapping in both phantom and clinical data. We show the method to be effective even in low signal to noise images and when the single-wrap-only assumption is violated. We illustrate a clinical use of our method in simulating bolus injection from PCA velocity data.
引用
收藏
页码:193 / 202
页数:10
相关论文
共 50 条
  • [41] A new 2D/3D Phase Unwrapping Strategy of Differential Interferograms SAR
    Hocine, Faiza
    Fekir, Mohamed
    Haddoud, Afifa
    Belhadj-aissa, Sawssen
    Belhadj-aissa, Aichouche
    JOURNAL OF THE INDIAN SOCIETY OF REMOTE SENSING, 2015, 43 (02) : 199 - 212
  • [42] Holographic and weak-phase projection systems for 3D shape reconstruction using temporal phase unwrapping
    Gonzalez, C. A.
    Davila, A.
    Garnica, G.
    APPLICATIONS OF DIGITAL IMAGE PROCESSING XXX, PTS 1 AND 2, 2007, 6696
  • [43] 3D Measurement of Human Chest and Abdomen Surface Based on 3D Fourier Transform and Time Phase Unwrapping
    Wu, Haibin
    Yu, Shuang
    Yu, Xiaoyang
    SENSORS, 2020, 20 (04)
  • [44] Unwrapping MR Phase Maps with Chebyshev Moments
    Langley, Jason A.
    Zhao, Qun
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 4043 - 4046
  • [45] Simple and accurate unwrapping phase of MR data
    Andris, Peter
    Frollo, Ivan
    MEASUREMENT, 2009, 42 (05) : 737 - 741
  • [46] Sensitivity of 3D phase contrast MRI flow measurements to background phase correction
    Callaghan, F.
    Burkhardt, B.
    Geiger, J.
    Buechel, Valsangiacomo E.
    Kellenberger, C.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2019, 20 : 356 - 356
  • [47] Phase contrast stereometry: Fatigue crack mapping in 3D
    Ignatiev, KI
    Lee, WK
    Fezzaa, K
    De Carlo, F
    Stock, SR
    DEVELOPMENTS IN X-RAY TOMOGRAPHY IV, 2004, 5535 : 253 - 260
  • [48] Absolute Phase Unwrapping with Deep Neural Network for Structured Light 3D Reconstruction
    Chang, Wan
    Xiang, Sen
    Deng, Huiping
    Wu, Jin
    PROCEEDINGS OF THE 33RD CHINESE CONTROL AND DECISION CONFERENCE (CCDC 2021), 2021, : 420 - 425
  • [49] Integrated phase unwrapping algorithm for the measurement of 3D shapes by Fourier transform profilometry
    Wu, Shuang-qing
    Zhang, Yin
    Zhang, San-yuan
    Ye, Xiu-zi
    JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE A, 2009, 10 (07): : 1018 - 1028
  • [50] 3D respiratory resolved phase contrast imaging of the aorta
    Eric M Schrauben
    Ashley G Anderson
    Kevin M Johnson
    Oliver Wieben
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)