Satellite temperature measurement in LEO and improvement method of temperature sensors calibration based on the measured data

被引:0
|
作者
Sieger, Ladislav [1 ,2 ]
Nentvich, Ondrej [1 ]
Urban, Martin [1 ]
机构
[1] Czech Tech Univ, Fac Elect Engn, Prague 16627, Czech Republic
[2] CTU Fac Elect Engn, Tech 2, Prague 16627, Czech Republic
关键词
instrumentation; detectors - radiation mechanism; thermal - space vehicles; instruments; CAPABILITIES; CUBESATS;
D O I
10.1002/asna.201913671
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
This article describes the temperature measurement and its calibration on board of the nanosatellite CubeSat class VZLUSAT-1. There are several thermometers, installed with an analog and a digital output, which are necessary for the accurate measurements calibrations under a vacuum condition or for applying postprocessing corrections. This document describes the way of calibration in a thermal vacuum chamber and its improvement in orbit. In addition, this article will discuss the use of a resistance temperature detector platinum sensors Pt1000 and a digital sensors HYT271 as the reference. A correction variable based on HYT271 compensates a nonlinearity of Pt1000 as well as minimizes the influence of change in a measuring current due to temperature changes. The current correction variable is a function of temperature and nanosatellite's position in the orbit. The measured temperatures are below -70 degrees C in the Earth's shadow and greater than +80 degrees C after irradiation by the Sun. Orbital temperature calibration is performed in two steps. The raw temperature data obtained during the orbital measurement are being used for further improvement. The measurement cycle consists of the electronics calibration, temperature measurement, and temperature calibration. After applying the temperature correction process, the final accuracy becomes better than +/- 0.15 degrees C.
引用
收藏
页码:652 / 657
页数:6
相关论文
共 50 条
  • [21] DYNAMIC CALIBRATION OF TEMPERATURE SENSORS FROM LIGHT RAYS FOR TRANSIENT MEASUREMENT
    Goswami, Rishikesh
    Kumar, Rakesh
    THERMAL SCIENCE, 2019, 23 (03): : 1901 - 1910
  • [22] Calibration and uncertainty analysis of temperature sensors
    Price, BA
    Smith, TF
    Suby, AA
    Klaassen, CJ
    SICON/01: ISA/IEEE SENSORS FOR INDUSTRY CONFERENCE, PROCEEDINGS, 2001, : 286 - 289
  • [23] Procedure for the extended calibration of temperature sensors
    Tomczyk, Krzysztof
    Ostrowska, Ksenia
    MEASUREMENT, 2022, 196
  • [24] Research on Calibration Method of Infrared Temperature Measurement System Near Room Temperature Field
    Cui, Shuanglong
    Xing, Jian
    FRONTIERS IN PHYSICS, 2022, 9
  • [25] Estimation method of underground improvement by temperature measurement in grouting
    Kawachi, T
    GROUTING AND DEEP MIXING, VOL 1, 1996, : 143 - 146
  • [26] Improvement and validation of the fluoroptic temperature-measurement method
    Janse, AMC
    de Jong, XA
    Prins, W
    van Swaaij, WPM
    AICHE JOURNAL, 1999, 45 (10) : 2087 - 2096
  • [27] Dimensional stability analysis of the satellite structure based on in-orbit temperature measurement data
    Luo Wenbo
    Zhang Xinwei
    Qian Zhiying
    Zhang Ling
    Bai Gang
    Mo Fan
    Lu Qingrong
    Yin Yazhou
    Fu Weichun
    CHINESE SPACE SCIENCE AND TECHNOLOGY, 2021, 41 (01) : 22 - 28
  • [28] Accuracy improvement in the source-based calibration of radiative heat flux sensors by consideration of the temperature non-uniformity of the high temperature blackbody
    Park, CW
    Lee, DH
    Kim, BH
    Park, SN
    Shin, HD
    METROLOGIA, 2006, 43 (01) : 135 - 141
  • [29] USE OF A DATA MEASUREMENT SYSTEM FOR STUDYING THE CHARACTERISTICS OF TEMPERATURE SENSORS
    Dubovitskii, V. A.
    Sebina, L. P.
    Godunov, M. V.
    Maksimova, E. M.
    FIBRE CHEMISTRY, 2011, 42 (06) : 399 - 403
  • [30] Use of a data measurement system for studying the characteristics of temperature sensors
    V. A. Dubovitskii
    L. P. Sebina
    M. V. Godunov
    E. M. Maksimova
    Fibre Chemistry, 2011, 42