Analysis of mitral valve morphology in dogs undergoing mitral valve repair with three-dimensional transesophageal

被引:2
|
作者
Mizuno, T. [1 ]
Chen, A. [1 ]
Mamada, K. [1 ]
Takahashi, A. [1 ]
Uchida, S. [1 ]
Uechi, M. [1 ]
机构
[1] JASMINE Vet Cardiovasc Med Ctr, 2-7-3 Nakagawa, Yokohama, Kanagawa 2240001, Japan
关键词
Annulus height to commissural width ra-tio; Myxomatous mitral valve disease; Saddle shape; Aortic-mitral angle;
D O I
10.1016/j.jvc.2021.01.004
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Introduction: Information about real-time three-dimensional (3D) transesophageal echocardiography (TEE) for the evaluation of canine mitral valve morphology is lacking in veterinary medicine. Objectives: To evaluate the feasibility of 3D TEE for the evaluation of canine mitral valves and whether there was a difference in mitral valve morphology between American College of Veterinary Internal Medicine (ACVIM) stages. Animals: Thirty-one dogs were evaluated, including nine dogs classified as ACVIM stage B2, 15 as stage C, and seven as stage D. Materials and methods: Three-dimensional TEE was performed after anesthetic induction for mitral valve surgery, and the 3D geometry of the mitral valve apparatus was measured. Results: The intraclass correlation coefficient was good in both inter- and intraobserver analyses of the 3D measurements of mitral valve annulus geometry and excellent in both inter- and intraobserver analyses in the 3D measurements of mitral valve annular and leaflet sizes. Annulus height to commissural width ratio of stage D dogs showed significantly lower values than B2 dogs (B2: 14.2% [9.1-20.5%]; C: 10.6% [6.5-24.1%]; D: 9.5% [4.7-13.8%]). The aortic-mitral angle of stages C and D were significantly flatter than stage B2 (B2: 122.32 +/- 9.39; C: 133.66 +/- 8.43; D: 140.70 +/- 10.70). Conclusions: Real-time 3D echocardiography using TEE is a feasible method to evaluate the morphology of the mitral valve in dogs. The saddle shape of the mitral annulus and aortic-mitral angle were flatter in stage D. Further studies are required to understand the pathology of mitral valve disease in dogs. & ordf; 2021 Elsevier B.V. All rights reserved.
引用
收藏
页码:64 / 72
页数:9
相关论文
共 50 条
  • [21] Quantitative Analysis of Mitral Valve Apparatus in Mitral Valve Prolapse Before and After Annuloplasty: A Three-Dimensional Intraoperative Transesophageal Study
    Maffessanti, Francesco
    Marsan, Nina A.
    Tamborini, Gloria
    Sugeng, Lissa
    Caiani, Enrico G.
    Gripari, Paola
    Alamanni, Francesco
    Jeevanandam, Valluvan
    Lang, Roberto M.
    Pepi, Mauro
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2011, 24 (04) : 405 - 413
  • [22] Detailed Transthoracic and Transesophageal Echocardiographic Analysis of Mitral Leaflets in Patients Undergoing Mitral Valve Repair
    Ali, Sarah Ghulam
    Fusini, Laura
    Tamborini, Gloria
    Muratori, Manuela
    Gripari, Paola
    Mapelli, Massimo
    Zanobini, Marco
    Alamanni, Francesco
    Pepi, Mauro
    AMERICAN JOURNAL OF CARDIOLOGY, 2016, 118 (01): : 113 - 120
  • [23] Parachute mitral valve accompanied by bicuspid aortic valve on three-dimensional transesophageal echocardiography
    Feng, Tian-Ying
    Li, Zhi-An
    He, Yi-Hua
    Han, Jian-Cheng
    Luan, Shu-Rong
    Wang, Lin-Lin
    KAOHSIUNG JOURNAL OF MEDICAL SCIENCES, 2012, 28 (09): : 506 - 508
  • [24] Three-dimensional changes in mitral valve annulus geometry in organic and functional mitral regurgitation: insights for mitral valve repair
    Mihaila, S.
    Muraru, D.
    Casablana, S.
    Peluso, D.
    Cucchini, U.
    Del Bianco, L.
    Vinereanu, D.
    Iliceto, S.
    Badano, L. P.
    EUROPEAN HEART JOURNAL, 2013, 34 : 858 - 858
  • [25] Mitral Valve Repair for Double-Orifice Mitral Valve With Flail Leaflet: The Usefulness of Real-Time Three-Dimensional Transesophageal Echocardiography
    Tani, Tomoko
    Kim, Kitae
    Fujii, Yoko
    Komori, Shigeru
    Okada, Yukikatsu
    Kita, Toru
    Furukawa, Yutaka
    ANNALS OF THORACIC SURGERY, 2012, 93 (04): : E97 - E98
  • [26] Three-dimensional echocardiography: Advancements in qualitative and quantitative analyses of mitral valve morphology in mitral valve prolapse
    Gripari, Paola
    Muratori, Manuela
    Fusini, Laura
    Tamborini, Gloria
    Pepi, Mauro
    JOURNAL OF CARDIOVASCULAR ECHOGRAPHY, 2014, 24 (01) : 1 - 9
  • [27] Three-dimensional transesophageal echocardiography guide mitral valve annuloplasty and papillary muscle relocation in functional mitral valve regurgitation
    Fattouch, K.
    Murana, G.
    Castrovinci, S.
    Sampognaro, R.
    Bertolino, E. C.
    Caccamo, G.
    Ruvolo, G.
    Speziale, G.
    Lancellotti, P.
    EUROPEAN HEART JOURNAL, 2012, 33 : 18 - 18
  • [28] Three dimensional versus two dimensinal transesophageal echocardiography in mitral valve repair
    Orta, R. Garcia
    Escobar, E. Moreno
    Alarcon, M. Vidal
    Lopez, M. F. Ruiz
    Ramirez, J. M. Oyonarte
    Torrano, J. Lara
    Herrero, T. Moreno
    Almagro, J. Azpitarte
    EUROPEAN HEART JOURNAL, 2006, 27 : 899 - 899
  • [29] Configuration analysis of mitral valve in patients with functional mitral regurgitation without mitral leaflet tenting by three-dimensional transesophageal echocardiography
    Maruo, T.
    Komiya, T.
    Fuku, Y.
    Yamamoto, H.
    Kadota, K.
    Mitsudo, K.
    EUROPEAN HEART JOURNAL, 2011, 32 : 1013 - 1013
  • [30] Mitral valve repair in dogs
    Uechi, Masami
    JOURNAL OF VETERINARY CARDIOLOGY, 2012, 14 (01) : 185 - 192