Design Charts for Combined Chilled Ceiling Displacement Ventilation System

被引:0
|
作者
Ghaddar, Nesreen [1 ,2 ]
Ghali, Kamel [3 ]
Saadeh, Ralph [1 ]
Keblawi, Amer [1 ]
机构
[1] Amer Univ Beirut, Dept Mech Engn, Beirut, Lebanon
[2] Amer Univ Beirut, Dept Mech Engn, Beirut, Lebanon
[3] Beirut Arab Univ, Beirut, Lebanon
来源
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper proposes operational design charts for combined chilled ceiling (CC) displacement ventilation (DV) hybrid air conditioning system (CC/DV). The design charts were developed by performing a large number of simulations using a simplified transport plume multi-layer model of the CC/DV conditioned space. The simulation model results were validated by conducting a series of experiments that showed good agreement with the predictions of the simplified model of the stratification height, the CC load, and the room air vertical temperature gradient. The proposed design charts, like any chart in the literature, are based on the important parameter of the ratio of the CC cooling load to the total load (R), the thermal comfort represented by the temperature gradient (dT/dZ), and the amount of displaced air parameter (P = (Q/<(m)over dot>)). The design chart parameters include the temperature ranges of the supply air temperature and the chilled ceiling for any R in the feasible design regions where dT/dZ is less than 2.5 K/m and with the facility to read of the stratification height H and insure that it is above 1.2 m. The stratification height was selected as an additional criterion to the thermal comfort because in humid warm climates, designing the CC/DV system for a high stratification height might be quite costly. The CC/DV design charts have shown that R can be met by different P = (Q/<(m)over dot>) for different air supply temperature and chilled ceiling temperatures and that the stratification height is strongly correlated to P = (Q/<(m)over dot>) compared to air and ceiling temperatures. Two correlations were developed at high predictability for the stratification height and vertical temperature gradient dependence on room height and system operational parameters.
引用
下载
收藏
页码:574 / +
页数:2
相关论文
共 50 条
  • [1] A combined system of chilled ceiling, displacement ventilation and desiccant dehumidification
    Hao, Xiaoli
    Zhang, Guoqiang
    Chen, Youming
    Zou, Shenghua
    Moschandreas, Demetrios. J.
    BUILDING AND ENVIRONMENT, 2007, 42 (09) : 3298 - 3308
  • [2] Optimized selection and operation of the combined chilled ceiling system and displacement ventilation
    Ghaddar, N.
    Ghali, K.
    Saadeh, R.
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2010, 34 (15) : 1328 - 1340
  • [3] Chilled ceiling displacement ventilation design charts correlations to employ in optimized system operation for feasible load ranges
    Keblawi, A.
    Ghaddar, N.
    Ghali, K.
    Jensen, L.
    ENERGY AND BUILDINGS, 2009, 41 (11) : 1155 - 1164
  • [4] Optimized Operation of Combined Chilled Ceiling Displacement Ventilation System Using Genetic Algorithm
    Mossolly, Mounir
    Ghaddar, Nesreen
    Ghali, Kamel
    Jensen, Lars
    ASHRAE TRANSACTIONS 2008, VOL 114, PT 2, 2008, 114 : 541 - +
  • [5] Room air stratification in combined chilled ceiling and displacement ventilation systems
    Schiavon, Stefano
    Bauman, Fred
    Tully, Brad
    Rimmer, Julian
    HVAC&R RESEARCH, 2012, 18 (1-2): : 147 - 159
  • [6] Optimized Strategy for Combined Liquid Desiccant Dehumidification Membrane with Chilled Ceiling and Displacement Ventilation System
    Muslmani, Mohamad
    Ghaddar, Nesreen
    Ghali, Kamel
    6TH INTERNATIONAL CONFERENCE ON ENERGY RESEARCH AND DEVELOPMENT, 2016, : 25 - 32
  • [7] Simplified thermal model of spaces cooled with combined positive displacement ventilation and chilled ceiling system
    Ayoub, Mohamad
    Ghaddar, Nesreen
    Ghali, Kamel
    HVAC&R RESEARCH, 2006, 12 (04): : 1005 - 1030
  • [8] Chilled ceiling and displacement ventilation system for energy savings: A case study
    Ghali, K.
    Ghaddar, N.
    Ayoub, M.
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2007, 31 (08) : 743 - 759
  • [9] Indoor thermal environment in rooms with combined air conditioning system of displacement ventilation and chilled ceiling panel
    School of Muni. and Eviron. Eng., Xi'an Univ. of Arch. and Tech, Xi'an 710055, China
    Xi'an Jianzhu Keji Daxue Xuebao, 2007, 4 (558-562):
  • [10] Experimental comparison of thermal conditions in office rooms: Diffuse ceiling ventilation, chilled beam system, and chilled ceiling combined with mixing ventilation
    Lestinen, Sami
    Mustakallio, Panu
    Kilpelainen, Simo
    Kosonen, Risto
    Jokisalo, Juha
    Koskela, Hannu
    Melikov, Arsen Krikor
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2020, 26 (05) : 631 - 642