Monte Carlo simulation of a PhosWatch detector using Geant4 for xenon isotope beta-gamma coincidence spectrum profile and detection efficiency calculations

被引:17
|
作者
Mekarski, P. [1 ]
Zhang, W. [1 ]
Ungar, K. [1 ]
Bean, M. [1 ]
Korpach, E. [1 ]
机构
[1] Hlth Canada, Radiat Protect Bur, Ottawa, ON K1A 1C1, Canada
关键词
Monte Carlo simulation; Geant4; Beta-gamma coincidence counting; Xenon isotopes; RADIOACTIVE XENON; SYSTEM;
D O I
10.1016/j.apradiso.2009.07.005
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
A simulation tool has been developed using the Geant4 Toolkit to simulate a PhosWatch single channel beta-gamma coincidence detection system consisting of a Csl(Tl)/BC404 Phoswich well detector and pulse shape analysis algorithms implemented digital signal processor. The tool can be used to simulate the detector's response for all the gamma rays and beta particles emitted from Xe-135, Xe-133m, Xe-133, Xe-131m and Pb-214. Two- and three-dimensional beta-gamma coincidence spectra from the PhosWatch detector can be produced using the simulation tool. The accurately simulated spectra could be used to calculate system coincidence detection efficiency for each xenon isotope, the corrections for the interference from the various spectral components from radon and xenon isotopes, and system gain calibration. Also, it can generate two- and three-dimensional xenon reference spectra to test beta-gamma coincidence spectral cleconvolution analysis software. Crown Copyright (C) 2009 Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1957 / 1963
页数:7
相关论文
共 41 条
  • [21] Simulation of p-type HPGe detector full-energy peak efficiency using GEANT4 Monte Carlo toolkit
    S. Penabeï
    D. Bongue
    A. B. Mistura
    P. Maleka
    K. M. Demdah
    G. N. M. Kwato
    International Journal of Environmental Science and Technology, 2024, 21 : 4509 - 4518
  • [22] Peak Efficiency of NaI Detector and Coincidence Summing Factor for Different Cylindrical Sources Using Geant4 Simulation
    Alzahrani, Jamila S.
    Almuqrin, Aljawhara H.
    HEALTH PHYSICS, 2021, 121 (03): : 202 - 208
  • [23] Monte Carlo simulation of the response of a germanium detector for low-level spectrometry measurements using GEANT4
    Hurtado, S
    García-León, M
    García-Tenorio, R
    APPLIED RADIATION AND ISOTOPES, 2004, 61 (2-3) : 139 - 143
  • [24] Single channel beta-gamma coincidence detection of radioactive xenon using digital pulse shape analysis of phoswich detector signals
    Hennig, Wolfgang
    Tan, Hui
    Warburton, William K.
    McIntyre, Justin I.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 510 - 514
  • [25] Implementation of detector response function modeling for small animal SPECT using Geant4 Monte Carlo Simulation Toolkit
    El Bitar, Ziad
    Brasse, David
    Gullberg, Grant
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [26] BETA-EFFICIENCY OF A TYPICAL GAS-FLOW IONIZATION CHAMBER USING GEANT4 MONTE CARLO SIMULATIONS
    Hussain, Abid
    Mirza, Sikander M.
    Mirza, Nasir M.
    Siddique, Muhammad T.
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2011, 26 (03): : 193 - 200
  • [27] Proton Therapy Range Verification Using Prompt Gamma Rays: A Simulation Study with the Geant4 Monte Carlo Toolkit
    Lau, A.
    Chen, Y.
    Ahmad, S.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [28] Single-channel beta-gamma coincidence detection of radioactive xenon using digital pulse shape analysis of phoswich detector signals
    Hennig, W
    Tan, H
    Warburton, WK
    McIntyre, JI
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (02) : 620 - 624
  • [29] Scintillation event localization in hemi-ellipsoid detector for SPECT, a simulation study using Geant4 Monte-Carlo
    Soysal, H. R.
    Dey, J.
    Donahue, W. P.
    Matthews, K. L.
    JOURNAL OF INSTRUMENTATION, 2022, 17 (05)
  • [30] Geant4 simulation of detection efficiency and self-attenuation effect of β particles for radioxenon measurement using β−γ coincidence equipment
    Qi Li
    Shilian Wang
    Yungang Zhao
    Yuanqing Fan
    Xinjun Zhang
    Ruiqin Zhang
    Huaimao Jia
    Zhi Zeng
    Journal of Radioanalytical and Nuclear Chemistry, 2021, 330 : 325 - 332