An oesophageal pulse oximetry system utilising a fibre-optic probe

被引:3
|
作者
Phillips, J. P. [1 ]
Langford, R. M. [2 ]
Chang, S. H. [2 ]
Maney, K. [2 ]
Kyriacou, P. A. [1 ]
Jones, D. P. [1 ]
机构
[1] City Univ London, Sch Engn & Math Sci, London EC1V 0HB, England
[2] St Bartholomew s Hosp, Anaesthet Lab, London EC1A 7BE, England
来源
关键词
BLOOD-OXYGEN SATURATION; CARDIOTHORACIC SURGERY;
D O I
10.1088/1742-6596/178/1/012021
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A dual-wavelength fibre-optic pulse oximetry system is described for the purposes of estimating oxygen saturation (SPO2) from the oesophagus. A probe containing miniature right-angled glass prisms was used to record photoplethysmographic (PPG) signals from the oesophageal wall. Signals were recorded successfully in 19 of 20 patients, demonstrating that PPG signals could be reliably obtained from an internal vascularised tissue site such as the oesophageal epithelium. The value of the mean oxygen saturation recorded from the oesophagus was 94.0 +/- 4.0%. These results demonstrate that SPO2 may be estimated in the oesophagus using a fibre-optic probe.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Preliminary evaluation of a new fibre-optic cerebral oximetry system
    Phillips, J. P.
    Langford, R. M.
    Kyriacou, P. A.
    Jones, D. P.
    PHYSIOLOGICAL MEASUREMENT, 2008, 29 (12) : 1383 - 1396
  • [2] Pulse oximetry at fibre-optic bronchoscopy in local anaesthesia: indication for postbronchoscopy oxygen supplementation?
    Kristensen, MS
    Milman, N
    Jarnvig, IL
    RESPIRATORY MEDICINE, 1998, 92 (03) : 432 - 437
  • [3] In situ salinity measurements in seawater with a fibre-optic probe
    Diaz-Herrera, N.
    Esteban, O.
    Navarrete, M. C.
    Le Haitre, M.
    Gonzalez-Cano, A.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2006, 17 (08) : 2227 - 2232
  • [4] Fibre-optic 100 fs pulse amplification and transmission system in the telecom range
    Krylov, A. A.
    Sazonkin, S. G.
    Kosolapov, A. F.
    Pryamikov, A. D.
    Kolyadin, A. N.
    Bufetov, I. A.
    QUANTUM ELECTRONICS, 2018, 48 (07) : 589 - 595
  • [5] Photoacoustic endoscopy probe using a coherent fibre-optic bundle
    Ansari, R.
    Zhang, E.
    Mathews, S.
    Desjardins, A. E.
    Beard, P. C.
    OPTO-ACOUSTIC METHODS AND APPLICATIONS IN BIOPHOTONICS II, 2015, 9539
  • [6] FLUORESCENCE DETECTION OF PHOTOSENSITIZING DRUGS USING A FIBRE-OPTIC PROBE
    KING, PR
    DAWSON, JB
    DRIVER, I
    ELLIS, DJ
    FEATHER, JW
    PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (01): : 193 - 193
  • [7] Novel probe for an evanescent wave fibre-optic absorption sensor
    Gupta, B.D.
    Tomar, A.K.
    Sharma, A.
    1995, Chapman & Hall Ltd, London, United Kingdom (27)
  • [8] Fibre-optic probe for fluorescence diagnostics with blood influence compensation
    Zherebtsov, Evgeny
    Dremin, Viktor
    Zharkikh, Elena
    Zherebtsova, Angelina
    Rafailov, Ilya
    Dunaev, Andrey
    Bazieva, Natalia
    Rafailov, Edik
    DYNAMICS AND FLUCTUATIONS IN BIOMEDICAL PHOTONICS XV, 2018, 10493
  • [9] Measurement of rotating blade tip clearance with fibre-optic probe
    Cao, S. Z.
    Duan, F. J.
    Zhang, Y. G.
    4th International Symposium on Instrumentation Science and Technology (ISIST' 2006), 2006, 48 : 873 - 877
  • [10] Characteristics of a high-temperature fibre-optic sensor probe
    Zhang, ZY
    Grattan, KTV
    Palmer, AW
    Meggitt, BT
    SENSORS AND ACTUATORS A-PHYSICAL, 1998, 64 (03) : 231 - 236