Evaluating the impact of x-ray spectral shape on image quality in flat-panel CT breast imaging

被引:48
|
作者
Glick, Stephen J. [1 ]
Thacker, Samta
Gong, Xing
Liu, Bob
机构
[1] Univ Massachusetts, Sch Med, Dept Radiol, Worcester, MA 01655 USA
[2] Radiat Monitoring Devices Inc, Watertown, MA 02172 USA
[3] Rush Univ, Med Ctr, Dept Med Phys & Radiat Oncol, Chicago, IL 60612 USA
[4] Massachusetts Gen Hosp, Boston, MA 02114 USA
关键词
D O I
10.1118/1.2388574
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In recent years, there has been an increasing interest in exploring the feasibility of dedicated computed tomography (CT) breast imaging using a flat-panel digital detector in a truncated cone-beam imaging, geometry. Preliminary results are promising and it appears as if three-dimensional tomographic imaging of the breast has great potential for reducing the masking effect of superimposed parenchymal structure typically observed with conventional mammography. In this study, a mathematical framework used for determining optimal design and acquisition parameters for such a CT breast imaging system is described. The ideal observer signal-to-noise ratio (SNR) is used as a figure of merit, under the assumptions that the imaging system is linear and shift invariant. Computation of the ideal observer SNR used a parallel-cascade model to predict signal and noise propagation through the detector, as well as a realistic model of the lesion detection task in breast imaging. For all evaluations, the total mean glandular dose for a CT breast imaging study was constrained to be approximately equivalent to that of a two-view conventional mammography study. The framework presented was used to explore the effect of x-ray spectral shape across an extensive ran-e of kVp settings, filter material types, and filter thicknesses. The results give an indication of how spectral shape can affect image quality in flat-panel CT breast imaging. (c) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:5 / 24
页数:20
相关论文
共 50 条
  • [1] X-ray scatter data for flat-panel detector CT
    Kyriakou, Yiannis
    Kalender, Willi A.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2007, 23 (01): : 3 - 15
  • [2] xCAT: A mobile, flat-panel volumetric X-ray CT for head and neck imaging
    Zbijewski, Wojciech
    Stayman, J. Webster
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 2985 - 2986
  • [3] Dual-energy cardiac imaging: an image quality and dose comparison for a flat-panel detector and x-ray image intensifier
    Ducote, Justin L.
    Xu, Tong
    Molloi, Sabee
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (01): : 183 - 196
  • [4] Direct-conversion flat-panel X-ray image detectors
    Kasap, SO
    Rowlands, JA
    IEE PROCEEDINGS-CIRCUITS DEVICES AND SYSTEMS, 2002, 149 (02): : 85 - 96
  • [5] A flat-panel X-ray imaging module for medical imaging and nondestructive testing
    Cho, Hyosung
    Choi, Sungil
    Lee, Bongsoo
    Kim, Sin
    ADVANCED NONDESTRUCTIVE EVALUATION I, PTS 1 AND 2, PROCEEDINGS, 2006, 321-323 : 1004 - 1007
  • [6] Flat-panel detectors in X-ray systems
    Spahn, M
    Heer, V
    Freytag, R
    RADIOLOGE, 2003, 43 (05): : 340 - +
  • [7] Scintillator-based flat-panel x-ray imaging detectors
    Granfors, Paul R.
    Albagli, Douglas
    JOURNAL OF THE SOCIETY FOR INFORMATION DISPLAY, 2009, 17 (06) : 535 - 542
  • [8] Effect of Oblique X-ray Incidence in Flat-Panel Computed Tomography of the Breast
    Badano, Aldo
    Kyprianou, Iacovos S.
    Freed, Melanie
    Jennings, Robert J.
    Sempau, Josep
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (05) : 696 - 702
  • [9] Quantitative image quality evaluation of pixel-binning in a flat-panel detector for x-ray fluoroscopy
    Srinivas, Y
    Wilson, DL
    MEDICAL PHYSICS, 2004, 31 (01) : 131 - 141
  • [10] A new x-ray imaging technique for radiography mode of flat-panel imager
    Suzuki, K.
    Ikeda, S.
    Ueda, K.
    Baba, R.
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510