Assessment of left ventricular function and mass in patients undergoing computed tomography (CT) coronary angiography using 64-Detector-Row CT:: Comparison to magnetic resonance imaging

被引:73
|
作者
Schlosser, T.
Mohrs, O. K.
Magedanz, A.
Voigtlaender, T.
Schmermund, A.
Barkhausen, J.
机构
[1] Univ Essen Gesamthsch, Dept Diagnost & Intervent Radiol, Essen, Germany
[2] Alice Hosp, Dept Cardiovasc Imaging, Darmstadt, Germany
关键词
cardiac; multislice computed tomography; myocardium;
D O I
10.1080/02841850601067611
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To quantify left ventricular function and mass derived from retrospectively ECG-gated 64-detector-row computed tomography coronary angiography data sets in comparison to cine magnetic resonance (MR) imaging as the reference standard. We hypothesized that the administration of beta-blockers prior to multidetector computed tomography (MDCT) coronary angiography has a significant impact on left ventricular functional parameters. Material and Methods: Multiplanar reformations in the short-axis orientation were calculated from axial contrast-enhanced CT images in 21 patients (16 male, five female; age range 41-75 years, mean 64.3+/-6.8 years) referred for CT coronary angiography. Patients whose heart rates exceeded 60 bpm received 5 mg bisoprolol orally I hour before the MDCT examination. In case of insufficient heart-rate reduction, up to four vials (20 mg) of metoprolol were injected intravenously. The end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), ejection fraction (EF), cardiac output (CO), and left ventricular mass (LVM) of the reformatted images were analyzed compared to volumetric measurements based on continuous short-axis steady-state free-precession cine MR sequences (TR 3 ms, TE 1.5 ms, FA 60). Results: On average, each patient received 15.5 mg metoprolol (range 0-20 mg) and 3.85 mg bisoprolol (range 0-5 mg). The mean heart rate was 56+/-5 bpm during CT and 73+/-9 bpm during MRI examination. This difference was statistically significant (P < 0.05). Mean EDV and ESV measured on MDCT were significantly higher compared to MR (MDCT vs. MR: EDV 164.2+/-52.5 vs. 144.2+/-46.7 ml, ESV 77.3+/-46.6 vs. 63.8+/-47.3 ml; P < 0.05). Mean EF and CO derived from MDCT images were significantly lower compared to MR (MDCT vs. MR: EF 55.4+/-11.8 vs. 59.3+/-15.4%, CO 4822+/-779 vs. 5755+/-1267 ml; P < 0.05). Mean SV and LVM were not significantly different between both methods (MDCT vs. MR: SV 86.8+/-18.1 vs. 80.3+/-15.6 ml, P = 0.44; LVM 132.4+/-42.5 vs. 138.7+/-39.1 g, P = 0.31). Conclusion: Left ventricular volumes assessed by the newest-generation MDCT scanners are significantly higher compared with MRI, whereas ejection fraction and cardiac output are significantly lower in MDCT. This appears to be a result of the frequent application of beta-blockers prior to MDCT examinations.
引用
收藏
页码:30 / 35
页数:6
相关论文
共 50 条
  • [31] Comparison of the 64-and 80-detector row computed tomography among the CT number and radiation dose during lower extremity computed tomography angiography
    Moriwake, Ryo
    Masuda, Takanori
    Yamamoto, Akira
    Ikenaga, Hiroyuki
    Yoshida, Koji
    Takei, Yasutaka
    Yao, Daiki
    Ono, Atsushi
    Hiratsuka, Junichi
    Tamada, Tsutomu
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (04) : 356 - 362
  • [32] Radiation dose exposure of patients undergoing 320-row cardiac CT for assessing coronary angiography and global left ventricular function
    Chien-Ming Chen
    Yuan-Chang Liu
    Chun-Chi Chen
    Ming-Shien Wen
    Chien-Fu Hung
    Yung-Liang Wan
    The International Journal of Cardiovascular Imaging, 2012, 28 : 1 - 5
  • [33] Radiation dose exposure of patients undergoing 320-row cardiac CT for assessing coronary angiography and global left ventricular function
    Chen, Chien-Ming
    Liu, Yuan-Chang
    Chen, Chun-Chi
    Wen, Ming-Shien
    Hung, Chien-Fu
    Wan, Yung-Liang
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 : 1 - 5
  • [34] In-vitro evaluation of coronary Stents and 64-detector-row computed tomography using a newly developed model of coronary artery stenosis
    Schlosser, T.
    Scheuermann, T.
    Ulzheimer, S.
    Mohrs, O. K.
    Kuhling, M.
    Albrecht, P. E.
    Voigtlander, T.
    Barkhausen, J.
    Schmermund, A.
    ACTA RADIOLOGICA, 2008, 49 (01) : 56 - 64
  • [35] Simultaneous Aortic and Coronary Assessment in Abdominal Aortic Aneurysm Patients by Thoraco-abdominal 64-Detector-row CT Angiography: Estimate of the Impact on Preoperative Management: A Pilot Study
    Budde, R. P. J.
    Huo, F.
    Cramer, M. J. M.
    Doevendans, P. A. F. M.
    Bots, M. L.
    Moll, F. L.
    Prokop, M.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2010, 40 (02) : 196 - 201
  • [36] Assessment of coronary stents using 40-detector row CT: Comparison with 16-detector row CT in vitro
    Suzuki, Shigeru
    Furui, Shigeru
    Kuwahara, Sadatoshi
    Vembar, Mani
    Kaminaga, Tatsuro
    Takei, Ryoji
    Isshiki, Takaaki
    Kozuma, Ken
    Aizawa, Tadanori
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2007, 31 (06) : 910 - 916
  • [37] The usefulness of subtraction coronary computed tomography angiography for in-stent restenosis assessment of patients with CoCr stent using 320-row area detector CT
    Li, Jian
    Guo, Man-Tao
    Yang, Xiao
    Gao, Fang
    Li, Na
    Huang, Ming-Gang
    MEDICINE, 2021, 100 (51) : E28345
  • [38] Feasibility and accuracy of coronary imaging in elderly patients using the 64-row multi-detector computed tomography: a correlation study with conventional coronary angiography
    Chee Khoon LIEW
    Sze Piaw CHIN
    Tiong Kiam ONG
    Seyfarth Tobias
    Yean Yip FONG
    Choon Kiat ANG
    Houng Bang LIEW
    Rapaee ANNUAR
    Kui Hian SIM
    Journal of Geriatric Cardiology, 2006, (01) : 9 - 14
  • [39] Incremental role of CT coronary angiography in the assessment of left ventricular diastolic function
    Lange, Aleksandra
    Huntress, Harry
    Steindl, Jesse
    Palka, Przemyslaw
    OPEN HEART, 2021, 8 (01):
  • [40] Impaired left ventricular function has a detrimental effect on image quality in multi-detector row CT coronary angiography
    Manghat, N. E.
    Morgan-Hughes, G. J.
    Shaw, S. R.
    Marshall, A. J.
    Roobottom, C. A.
    CLINICAL RADIOLOGY, 2008, 63 (04) : 415 - 423