Comparison of Two Commercial ELISA Kits for the Detection of Anti-Dengue IgM for Routine Dengue Diagnosis in Laos

被引:4
|
作者
Lu, Yixiao [1 ,5 ]
Sengvilaipaseuth, Onanong [1 ]
Chanthongthip, Anisone [1 ]
Phonemixay, Ooyanong [1 ]
Vongsouvath, Manivanh [1 ]
Phouminh, Phonelavanh [1 ]
Blacksell, Stuart D. [2 ,3 ]
Newton, Paul N. [1 ,3 ]
Dubot-Peres, Audrey [1 ,3 ,4 ]
机构
[1] Mahosot Hosp, Lao Oxford Mahosot Hosp Wellcome Trust Res Unit L, Microbiol Lab, Viangchan 01000, Laos
[2] Mahidol Univ, Fac Trop Med, Mahidol Oxford Trop Med Res Unit, Bangkok 10400, Thailand
[3] Univ Oxford, Churchill Hosp, Ctr Trop Med & Global Hlth, Nuffield Dept Clin Med, Oxford OX3 7LJ, England
[4] UVE Aix Marseille Univ, Unite Virus Emergents, IRD 190, Inserm 1207,IHU Mediterranee Infect, F-13005 Marseille, France
[5] Nagasaki Univ, Grad Sch Biomed Sci, Dept Publ Hlth Adv Prevent Med, Nagasaki 8528534, Japan
基金
英国惠康基金;
关键词
dengue; MAC-ELISA; serology; Laos; IgM; LINKED-IMMUNOSORBENT-ASSAY; IMMUNOGLOBULIN-M; PATHOGENIC LEPTOSPIRA; TAQMAN ASSAY; TESTS;
D O I
10.3390/tropicalmed4030111
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
The endemicity of Dengue virus (DENV) infection remains a major public health problem in Lao PDR. In this study, we compared two commercial anti-dengue IgM ELISA kits, Panbio (R) Dengue IgM Capture ELISA (Panbio Kit, Alere, Waltham, MA, USA) and DEN DetectTM MAC-ELISA (InBios kit, InBios International, Inc., Seattle, WA, USA), in the context of diagnosis of patients admitted to hospital with clinical dengue presentation. Two panels of paired blood samples were tested. Panel A was composed of 54 dengue confirmed patients (by DENV real-time RT-PCR) and 11 non-dengue dengue patients (other infections confirmed by corresponding PCR results). Panel B included 74 patients randomly selected from consecutive patients admitted to Mahosot Hospital in 2008 with suspicion of dengue fever according to WHO criteria. Results from panel A showed significantly better sensitivity for Panbio kit (64.8%; 95%CI: 50.6-77.3%) than for InBios kit (18.5%; 95%CI: 9.3-31.4%) when testing admission sera. Sensitivity was increased for both kits when combining results from admission and convalescent sera. Concordant results were obtained from panel B with fair agreement (kappa = 0.29) between both kits when testing single admission samples, and moderate agreement ( kappa = 0.5) when combining results from admission and convalescent sera.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Comparison of two commercial kits and an in-house ELISA for the detection of equine rotavirus in foal feces
    Mino, S.
    Kern, A.
    Barrandeguy, M.
    Parreno, V.
    [J]. JOURNAL OF VIROLOGICAL METHODS, 2015, 222 : 1 - 10
  • [42] DETECTING ARTIFICIAL ANTI-DENGUE IGM IMMUNE-COMPLEXES USING AN ENZYME-LINKED-IMMUNOSORBENT-ASSAY
    KUNO, G
    GOMEZ, I
    GUBLER, DJ
    [J]. AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 1987, 36 (01): : 153 - 159
  • [43] Evaluation of the MRL diagnostics dengue fever virus IgM capture ELISA and the PanBio Rapid Immunochromatographic Test for diagnosis of dengue fever in Jamaica
    Palmer, CJ
    King, SD
    Cuadrado, PR
    Perez, E
    Baum, M
    Ager, AL
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1999, 37 (05) : 1600 - 1601
  • [44] Recent two-year advances in anti-dengue small-molecule inhibitors
    Yang, Chao
    Xie, Wansheng
    Zhang, Heqian
    Xie, Wenjian
    Tian, Tiantian
    Qin, Zhiwei
    [J]. EUROPEAN JOURNAL OF MEDICINAL CHEMISTRY, 2022, 243
  • [45] Comparison of commercial allergen ELISA kits for egg detection in food matrices
    Smits, Nathalie G. E.
    De Dominicis, Emiliano
    Koops, Andries J.
    Kraan, Rian
    Saner, Samim
    Van Der Fels-Klerx, H. J.
    den Hil, Elise Hoek-van
    [J]. HELIYON, 2023, 9 (10)
  • [46] Evaluation of a commercial dengue NS1 antigen-capture ELISA for laboratory diagnosis of acute dengue virus infection
    Kumarasamy, V.
    Wahab, A. H. Abdul
    Chua, S. K.
    Hassan, Z.
    Chem, Y. K.
    Mohamad, M.
    Chua, K. B.
    [J]. JOURNAL OF VIROLOGICAL METHODS, 2007, 140 (1-2) : 75 - 79
  • [47] Comparison of a rapid immuno-chromatography assay with a standard ELISA for the detection of IgM and IgG antibodies against dengue viruses
    Murugananthan K.
    Coonghe P.A.D.
    Ketheesan N.
    Noordeen F.
    [J]. VirusDisease, 2018, 29 (2) : 199 - 202
  • [48] Comparison of two automated commercial assays for routine detection of anti-hepatitis E Virus IgM antibodies in clinical samples
    Becquart, Adrien
    Guigon, Aurelie
    Regueme, Alexandre
    Coulon, Pauline
    Bocket, Laurence
    Hober, Didier
    Alidjinou, Enagnon Kazali
    [J]. DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2024, 109 (01)
  • [49] Significance of IgG optical density ratios (index value) in single reactive anti-Dengue virus IgG capture ELISA
    Chatterjee, Shiv Sekhar
    Sharma, Ankush
    Choudhury, Shilpee
    Chumber, Sushil Kumar
    Kaur, Mandeep
    Bage, Ras
    Parkhe, Nittin
    Khanduri, Uma
    [J]. IRANIAN JOURNAL OF MICROBIOLOGY, 2016, 8 (06) : 395 - 400
  • [50] Comparison of three commercial ELISA kits for the detection of turkey rhinotracheitis virus antibodies
    Mekkes, DR
    de Wit, JJ
    [J]. AVIAN PATHOLOGY, 1998, 27 (03) : 301 - 305