Modification of polyethersulfone using sericin and polyvinylpyrrolidone for cadmium ion removal by polyelectrolyte-enhanced ultrafiltration

被引:8
|
作者
Thuyavan, Y. Lukka [1 ]
Anantharaman, N. [1 ]
Arthanareeswaran, G. [1 ]
Ismail, A. F. [2 ]
机构
[1] Natl Inst Technol, Dept Chem Engn, Membrane Res Lab, Tiruchirappalli 620015, Tamil Nadu, India
[2] Univ Teknol Malaysia, Adv Membrane Technol Res Ctr AMTEC, Utm Skudai 81310, Johor, Malaysia
关键词
Membrane modification; Polyvinylpyrrolidone and sericin; Hydrophilicity; Cadmium ion removal; Maximum retention capacity; NANOFILTRATION MEMBRANES; SURFACE MODIFICATION; BLEND MEMBRANES; PERFORMANCE; WATER; MORPHOLOGY; SEPARATION; POLYMERS;
D O I
10.1080/19443994.2014.934738
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The present study deals with the synthesis of polyethersulfone (PES)-based membrane using a biopolymer sericin and polyvinylpyrrolidone (PVP) by phase inversion process. The synthesized membranes were characterized for hydrophilicity, pure water permeability (PWP), membrane stability, and surface functional group analysis. The synthesized membranes were used to study the effective removal of cadmium ions using poly(diallyldimethylammoniumchloride) and polyethyleneimine (PEI) by polyelectrolyte-enhanced ultrafiltration. PVP-sericin-incorporated PES membrane resulted in the highest average pore radius (22nm) and PWP (34.11Lm(-2)h(-1)bar(-1)). It also showed that higher antifouling resistance of 10 folds than neat PES membrane retained the higher flux rate. Overall, PES/sericin/PVP membrane has better characteristics, and maximum percentage of cadmium removal was obtained when added with PEI ligand.
引用
收藏
页码:366 / 378
页数:13
相关论文
共 50 条
  • [21] Use of polyelectrolyte-enhanced ultrafiltration to remove chromate from water
    Sriratana, S
    Scamehorn, JF
    Chavadej, S
    Saiwan, C
    Haller, KJ
    Christian, SD
    Tucker, EE
    [J]. SEPARATION SCIENCE AND TECHNOLOGY, 1996, 31 (18) : 2493 - 2504
  • [22] NEURAL NETWORK MODEL PREDICTION OF CHROMIUM SEPARATION IN POLYELECTROLYTE-ENHANCED ULTRAFILTRATION
    Korus, Irena
    Piotrowski, Krzysztof
    [J]. ECOLOGICAL CHEMISTRY AND ENGINEERING A-CHEMIA I INZYNIERIA EKOLOGICZNA A, 2014, 21 (03): : 377 - 385
  • [23] Removal of Cr(III) and Cr(VI) ions from aqueous solutions by means of polyelectrolyte-enhanced ultrafiltration
    Korus, Irena
    Loska, Krzysztof
    [J]. DESALINATION, 2009, 247 (1-3) : 390 - 395
  • [24] Application of Polyelectrolyte-Enhanced Ultrafiltration for Rhenium Recovery from Aqueous Solutions
    Zeng, Jianxian
    Li, Shu
    Sun, Xiahui
    Chen, Xiaoxiao
    [J]. CHEMICAL ENGINEERING & TECHNOLOGY, 2012, 35 (02) : 387 - 392
  • [25] Kinetic modeling for dye removal using polyelectrolyte enhanced ultrafiltration
    Mondal, Sourav
    Ouni, Hedia
    Dhahbi, Mahmoud
    De, Sirshendu
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2012, 229 : 381 - 389
  • [26] ECONOMIC-FEASIBILITY STUDY OF POLYELECTROLYTE-ENHANCED ULTRAFILTRATION (PEUF) FOR WATER SOFTENING
    TABATABAI, A
    SCAMEHORN, JF
    CHRISTIAN, SD
    [J]. JOURNAL OF MEMBRANE SCIENCE, 1995, 100 (03) : 193 - 207
  • [27] Development and characterization of porous membranes based on PPSU/PES using polyethylene glycol as porogen: Application for cobalt removal by polyelectrolyte-enhanced ultrafiltration
    Nafti-Mateur, Molka
    Jaouadi, Mouna
    Van der Bruggen, Bart
    Naifer, Karima Horchani
    Ennigrou, Dorra Jellouli
    [J]. JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2024, 99 (02) : 343 - 354
  • [28] Removal of dyes from wastewater using polyelectrolyte enhanced ultrafiltration (PEUF)
    Ouni, Hedia
    Dhahbi, Mahmoud
    [J]. DESALINATION AND WATER TREATMENT, 2010, 22 (1-3) : 355 - 362
  • [29] Polyelectrolyte modification of ultrafiltration membrane for removal of copper ions
    Magnenet, C.
    Jurin, F. E.
    Lakard, S.
    Buron, C. C.
    Lakard, B.
    [J]. COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2013, 435 : 170 - 177
  • [30] Use of polyelectrolyte-enhanced ultrafiltration to remove chromate from polluted ground water.
    Sriratana, S
    Scamehorn, JF
    Chavadej, S
    Saiwan, C
    Haller, KJ
    Christian, SD
    Tucker, EE
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1997, 213 : 120 - IEC