The CMS ECAL laser monitoring system

被引:0
|
作者
Bornheim, Adolf [1 ]
机构
[1] CALTECH, Pasadena, CA 91125 USA
来源
CALORIMETRY IN HIGH ENERGY PHYSICS | 2006年 / 867卷
关键词
lead tungstate crystal calorimeter; CMS ECAL; monitoring system;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The CMS detector at LHC will be equipped with a high precision lead tungstate electromagnetic calorimeter. To ensure the stability of the calorimetric response at a level of a few per mille, every channel of the detector is monitored with a laser system. This system allows to correct for fluctuations in the detector response with high precision, in particular the expected radiation induced changes of the crystal transparency, which are on the level of several per cent at nominal luminosity. Here we report results from long term tests of the system on fully equipped supermodules of the CMS ECAL which are performed after the final step of the construction but before insertion of the modules in CMS. The in-situ monitoring strategy for the CMS ECAL is discussed in detail and the performance of the full monitoring procedure as achieved in the test beam is illustrated.
引用
收藏
页码:408 / 414
页数:7
相关论文
共 50 条
  • [41] Mitigation of anomalous APD signals in the CMS ECAL
    Bialas, W.
    Petyt, D. A.
    JOURNAL OF INSTRUMENTATION, 2013, 8
  • [42] CMS ECAL VFE design, production and testing
    Lustermann, W.
    Abadjiev, D.
    Dissertori, G.
    Dejardin, M.
    Gadek, T.
    Martin, L. T.
    Stachon, K.
    JOURNAL OF INSTRUMENTATION, 2024, 19 (05):
  • [43] The ECAL online software in the commissioning of the CMS detector
    Musella, Pasquale
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 617 (1-3): : 303 - 305
  • [44] Testability issues in the CMS ECAL upper-level readout and trigger system
    Almeida, CB
    Teixeira, IC
    Teixeira, JP
    Varela, J
    Augusto, J
    Santos, M
    Cardoso, N
    PROCEEDINGS OF THE FIFTH WORKSHOP ON ELECTRONICS FOR LHC EXPERIMENTS, 1999, : 361 - 365
  • [45] Radiation hard avalanche photodiodes for CMS ECAL
    Grahl, J
    Kronquist, I
    Rusack, R
    Singovski, A
    Kumetsov, A
    Musienko, Y
    Reucroft, S
    Swain, J
    Deiters, K
    Ingram, Q
    Renker, D
    Sakhelashvili, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 504 (1-3): : 44 - 47
  • [46] The performance of the CMS ECAL Preshower detector at LHC
    Liu, Zong-Kai
    Kuo, Chia-Ming
    Li, Syue-Wei
    35TH INTERNATIONAL CONFERENCE OF HIGH ENERGY PHYSICS (ICHEP 2010), 2010,
  • [47] CMS ECAL APD quality assurance facility
    Deiters, K
    Ingram, Q
    Renker, D
    Sakhelashvili, T
    Patel, B
    Rusack, R
    Singovski, A
    Vikas, P
    Musienko, Y
    Nicol, S
    Reucroft, S
    Swain, J
    PROCEEDINGS OF THE SIXTH WORKSHOP ON ELECTRONICS FOR LHC EXPERIMENTS, 2000, 2000 (10): : 221 - 225
  • [48] Hamamatsu APD for CMS ECAL: quality insurance
    Bailleux, D
    Britvitch, I
    Deiters, K
    Egeland, R
    Gilbert, B
    Grahl, J
    Ingram, Q
    Kuznetsov, A
    Lester, E
    Musienko, Y
    Renker, D
    Reucroft, S
    Rusack, R
    Sakhelashvili, T
    Singovski, A
    Swain, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 518 (1-2): : 622 - 625
  • [49] A study of the monitoring of radiation damage to CMS ECAL crystals, performed at X5-GIF
    Davies, G
    Peigneux, JP
    Singovski, A
    Seez, C
    JOURNAL OF PHYSICS G-NUCLEAR AND PARTICLE PHYSICS, 2000, 26 (11) : 1735 - 1749
  • [50] CMS ECAL electronics developments for HL-LHC
    Hansen, M.
    JOURNAL OF INSTRUMENTATION, 2015, 10