Implementation and evaluation of various demons deformable image registration algorithms on a GPU

被引:194
|
作者
Gu, Xuejun [1 ]
Pan, Hubert [1 ]
Liang, Yun [1 ]
Castillo, Richard [2 ]
Yang, Deshan [3 ]
Choi, Dongju [4 ]
Castillo, Edward [5 ]
Majumdar, Amitava [4 ]
Guerrero, Thomas [5 ]
Jiang, Steve B. [1 ]
机构
[1] Univ Calif San Diego, Dept Radiat Oncol, La Jolla, CA 92037 USA
[2] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX 77030 USA
[3] Washington Univ, Dept Radiat Oncol, Sch Med, St Louis, MO 63110 USA
[4] Univ Calif San Diego, San Diego Supercomp Ctr, La Jolla, CA 92093 USA
[5] Univ Texas MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX 77030 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2010年 / 55卷 / 01期
关键词
ADAPTIVE RADIATION-THERAPY; PLAN MODIFICATION; DOSE CALCULATION; RE-OPTIMIZATION; IMRT; RECONSTRUCTION; VALIDATION;
D O I
10.1088/0031-9155/55/1/012
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Online adaptive radiation therapy (ART) promises the ability to deliver an optimal treatment in response to daily patient anatomic variation. A major technical barrier for the clinical implementation of online ART is the requirement of rapid image segmentation. Deformable image registration (DIR) has been used as an automated segmentation method to transfer tumor/organ contours from the planning image to daily images. However, the current computational time of DIR is insufficient for online ART. In this work, this issue is addressed by using computer graphics processing units (GPUs). A gray-scale-based DIR algorithm called demons and five of its variants were implemented on GPUs using the compute unified device architecture (CUDA) programming environment. The spatial accuracy of these algorithms was evaluated over five sets of pulmonary 4D CT images with an average size of 256 x 256 x 100 and more than 1100 expert-determined landmark point pairs each. For all the testing scenarios presented in this paper, the GPU-based DIR computation required around 7 to 11 s to yield an average 3D error ranging from 1.5 to 1.8 mm. It is interesting to find out that the original passive force demons algorithms outperform subsequently proposed variants based on the combination of accuracy, efficiency and ease of implementation.
引用
收藏
页码:207 / 219
页数:13
相关论文
共 50 条
  • [21] A Contour-guided Demons Deformable Image Registration Algorithm For Adaptive Radiotherapy
    Gu, X.
    Jia, X.
    Dong, B.
    Gautier, Q.
    Jiang, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S803 - S804
  • [22] Evaluation of the deformable image registration algorithm in Velocity image registration software
    Fullarton, R.
    Ghirmay, K.
    Dom, W.
    Crees, L.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S974 - S974
  • [23] Validation of three deformable image registration algorithms for the thorax
    Latifi, Kujtim
    Zhang, Geoffrey
    Stawicki, Marnix
    van Elmpt, Wouter
    Dekker, Andre
    Forster, Kenneth
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (01): : 19 - 30
  • [24] HARDWARE IMPLEMENTATION OF IMAGE REGISTRATION ALGORITHMS
    RANGANATH, HS
    IMAGE AND VISION COMPUTING, 1986, 4 (03) : 151 - 158
  • [25] Faster dense deformable image registration by utilizing both CPU and GPU
    Ekstrom, Simon
    Pilia, Martino
    Kullberg, Joel
    Ahlstrom, Hakan
    Strand, Robin
    Malmberg, Filip
    JOURNAL OF MEDICAL IMAGING, 2021, 8 (01)
  • [26] Implementation of Image Processing Algorithms Based on GPU
    Tsmots, Ivan
    Berezkyi, Oleh
    Ihnatiev, Ihor
    Gumovska, Iryna
    2016 XITH INTERNATIONAL SCIENTIFIC AND TECHNICAL CONFERENCE COMPUTER SCIENCES AND INFORMATION TECHNOLOGIES (CSIT), 2016, : 27 - 29
  • [27] Evaluation of the Velocity Deformable Image Registration Algorithm
    Polan, D.
    Kamp, J.
    Lee, J. Y.
    Chapman, C.
    Green, M.
    Payal, S.
    Kessler, M.
    Brock, K.
    MEDICAL PHYSICS, 2016, 43 (06) : 3426 - 3426
  • [28] Extra-dimensional Demons: A method for incorporating missing tissue in deformable image registration
    Nithiananthan, Sajendra
    Schafer, Sebastian
    Mirota, Daniel J.
    Stayman, J. Webster
    Zbijewski, Wojciech
    Reh, Douglas D.
    Gallia, Gary L.
    Siewerdsen, Jeffrey H.
    MEDICAL PHYSICS, 2012, 39 (09) : 5718 - 5731
  • [29] Validation of an Improved 'Diffeomorphic Demons' Algorithm for Deformable Image Registration in Image-Guided Radiation Therapy
    Zhou, Lu
    Zhou, Linghong
    Zhang, Shuxu
    Zhen, Xin
    Yu, Hui
    Zhang, Guoqian
    Wang, Ruihao
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2014, 24 (01) : 373 - 382
  • [30] MIND Demons for MR-to-CT Deformable Image Registration In Image-Guided Spine Surgery
    Reaungamornrat, S.
    De Silva, T.
    Uneri, A.
    Wolinsky, J. -P.
    Khanna, A. J.
    Kleinszig, G.
    Vogt, S.
    Prince, J. L.
    Siewerdsen, J. H.
    MEDICAL IMAGING 2016: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2016, 9786