4D CT analysis of organs at risk (OARs) in stereotactic radiotherapy

被引:0
|
作者
Nardone, V. [1 ]
Giugliano, F. M. [1 ]
Reginelli, A. [2 ]
Cappabianca, S. [3 ]
Mormile, M. [1 ]
Guida, C. [1 ]
机构
[1] Osped Mare, UOC Radioterapia, Naples, Italy
[2] Univ Campania, Dept Precis Med, Naples, Italy
[3] Univ Campania Luigi Vanvitelli, Med Precis, Caserta, Italy
关键词
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
70P
引用
收藏
页码:S733 / S733
页数:1
相关论文
共 50 条
  • [21] Impact of Intrafractional Motion On TomoTherapy Stereotactic Body Radiotherapy (SBRT) 4D Dosimetry
    Lian, J.
    Matney, J.
    Chao, E.
    Chang, S.
    Zagar, T.
    Wang, A.
    Chera, B.
    Das, S.
    Schreiber, E.
    MEDICAL PHYSICS, 2015, 42 (06) : 3204 - 3204
  • [22] Deformable registration of 4D CT in lung sterecitactic radiotherapy planning
    Vik, T.
    Kaus, M.
    Franks, K.
    Bissonnette, J-P.
    Purdie, T.
    Bezjak, A.
    Jaffray, D.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S98 - S99
  • [23] THE USE OF 4D CT SCANNING IN RADICAL RADIOTHERAPY FOR LUNG CANCER
    Huang, V.
    Liu, M.
    Khaira, M.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S59 - S59
  • [24] Evaluation of the cone beam CT for internal target volume localization in lung stereotactic radiotherapy in comparison with 4D MIP images
    Wang, Lu
    Chen, Xiaoming
    Lin, Mu-Han
    Xue, Jun
    Lin, Teh
    Fan, Jiajin
    Jin, Lihui
    Ma, Charlie M.
    MEDICAL PHYSICS, 2013, 40 (11)
  • [25] Evaluation of 4D CT-On-Rails Target Localization Methods for Free Breathing Liver Stereotactic Body Radiotherapy (SBRT)
    Fan, J.
    Lin, T.
    Jin, L.
    Chen, L.
    Veltchev, I.
    Wang, L.
    Eldib, A.
    Chibani, O.
    Wang, B.
    Xu, Q.
    Price, R.
    Ma, C.
    MEDICAL PHYSICS, 2016, 43 (06) : 3727 - 3727
  • [26] A new radiotherapy technique: the 4D radiotherapy
    Simon, L
    Giraud, P
    Servois, V
    Rosenwald, J
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S231 - S232
  • [27] Respiratory gated radiotherapy: the 4D radiotherapy
    Giraud, P
    Simon, L
    Saliou, M
    Reboul, F
    Garcia, R
    Carrie, C
    Lerolle, U
    Rosenwald, JC
    Cosset, JM
    BULLETIN DU CANCER, 2005, 92 (01) : 83 - 89
  • [28] Implementing 4D XCAT Phantom for 4D Radiotherapy Research
    Panta, R.
    Segars, W.
    Yin, F.
    Cai, J.
    MEDICAL PHYSICS, 2012, 39 (06) : 3686 - 3686
  • [29] Geometrical differences in target volumes between slow CT and 4D CT imaging in stereotactic body radiotherapy for lung tumors in the upper and middle lobe
    Nakamura, Mitsuhiro
    Narita, Yuichiro
    Matsuo, Yukinori
    Narabayashi, Masaru
    Nakata, Manabu
    Yano, Shinsuke
    Miyabe, Yuki
    Matsugi, Kiyotomo
    Sawada, Akira
    Norihisa, Yoshiki
    Mizowaki, Takashi
    Nagata, Yasushi
    Hiraoka, Masahiro
    MEDICAL PHYSICS, 2008, 35 (09) : 4142 - 4148
  • [30] Phase Correlated Image Registration to 4D CT for Liver Stereotactic Radiosurgery with Image Guidance CT
    Juh, R.
    Suh, T.
    MEDICAL PHYSICS, 2010, 37 (06)