Paper-based enzymatic reactors for batch injection analysis of glucose on 3D printed cell coupled with amperometric detection

被引:56
|
作者
Dias, Anderson A. [1 ]
Cardoso, Thiago M. G. [1 ]
Cardoso, Rafael M. [2 ]
Duarte, Lucas C. [1 ]
Munoz, Rodrigo A. A. [2 ]
Richter, Eduardo M. [2 ]
Coltro, Wendell K. T. [1 ]
机构
[1] Univ Fed Goias, Inst Quim, BR-74690900 Goiania, Go, Brazil
[2] Univ Fed Uberlandia, Inst Quim, BR-38408100 Uberlandia, MG, Brazil
关键词
Chemical modification; Diabetes diagnosis; Disposable devices; Electrochemical detection; Microfluidic paper-based analytical devices; Paper biosensor; DIRECT ELECTRON-TRANSFER; ELECTROCHEMICAL DETECTION; ANALYTICAL DEVICES; CELLULOSE PAPER; SOL-GEL; OXIDASE; BIOSENSOR; CARBON; HYDROCHLOROTHIAZIDE; PARACETAMOL;
D O I
10.1016/j.snb.2015.11.040
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This report describes for the first time the development of paper-based enzymatic reactors (PERs) for the detection of glucose (Glu) in artificial serum sample using a 3D printed batch injection analysis (BIA) cell coupled with electrochemical detection. The fabrication of the PERs involved firstly the oxidation of the paper surface with a sodium periodate solution. The oxidized paper was then perforated with a paper punch to create microdisks and activated with a solution containing N-hydroxysuccinimide (NHS) and N-(3-dimethylaminopropyl)-N'-ethylcarbodiimide hydrochloride (EDC). Glucose oxidase (GOx) enzyme was then covalently immobilized on paper surface to promote the enzymatic assay for the detection of Glu in serum sample. After the addition of Glu on the PER surface placed inside a plastic syringe, the analyte penetrated through the paper surface under vertical flow promoting the enzymatic assay. The reaction product (H2O2) was collected with an electronic micropipette in a microtube and analyzed in the 3D BIA cell coupled with screen-printed electrodes (SPEs). The overall preparation time and the cost estimated per PER were 2.5 h and $0.02, respectively. Likewise the PERs, the use of a 3D printer allowed the fabrication of a BIA cell within 4 hat cost of $5. The coupling of SPE with the 3D printed cell exhibited great analytical performance including repeatability and reproducibility lower than 2% as well as high sampling rate (30 injections h(-1)) under low injection volume (10 mu L). The limit of detection (LD) and linear range achieved with the proposed approach was 0.11 mmol L-1 and 1-10 mmol L-1, respectively. Lastly, the glucose concentration level was successfully determined using the proposed method and the values found were not statistically different from the data achieved by a reference method at confidence level of 95%. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:196 / 203
页数:8
相关论文
共 50 条
  • [31] Screen printed 3D microfluidic paper-based and modifier-free electroanalytical device for clozapine sensing
    Ghanbari, Mohammad Hossein
    Biesalski, Markus
    Friedrich, Oliver
    Etzold, Bastian J. M.
    ANALYST, 2024, 149 (22) : 5411 - 5422
  • [32] 3D paper-based microfluidic device: a novel dual-detection platform of bisphenol A
    Yukird, Jutiporn
    Soum, Veasna
    Kwon, Oh-Sun
    Shin, Kwanwoo
    Chailapakul, Orawon
    Rodthongkum, Nadnudda
    ANALYST, 2020, 145 (04) : 1491 - 1498
  • [33] PaperCraft3D: Paper-Based 3D Modeling and Scene Fabrication
    Paczkowski, Patrick
    Dorsey, Julie
    Rushmeier, Holly
    Kim, Min H.
    IEEE TRANSACTIONS ON VISUALIZATION AND COMPUTER GRAPHICS, 2019, 25 (04) : 1717 - 1731
  • [34] Paper-Based Analytical Device for Electrochemical Flow-Injection Analysis of Glucose in Urine
    Lankelma, Jan
    Nie, Zhihong
    Carrilho, Emanuel
    Whitesides, George M.
    ANALYTICAL CHEMISTRY, 2012, 84 (09) : 4147 - 4152
  • [35] Novel 3D Printed Microfluidic Paper-Based Analytical Device With Integrated Screen-Printed Electrodes for Automated Viscosity Measurements
    Puneeth, S. B.
    Goel, Sanket
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 2019, 66 (07) : 3196 - 3201
  • [36] Fast Determination of Ciprofloxacin by Batch Injection Analysis with Amperometric Detection and Capillary Electrophoresis with Capacitively Coupled Contactless Conductivity Detection
    Montes, Rodrigo H. O.
    Marra, Mariana C.
    Rodrigues, Monike M.
    Richter, Eduardo M.
    Munoz, Rodrigo A. A.
    ELECTROANALYSIS, 2014, 26 (02) : 432 - 438
  • [37] Determination of propranolol and hydrochlorothiazide by batch injection analysis with amperometric detection and capillary electrophoresis with capacitively coupled contactless conductivity detection
    Gimenes, Denise Tofanello
    Marra, Mariana Cardoso
    Abarza Munoz, Rodrigo Alejandro
    Angnes, Lucio
    Richter, Eduardo Mathias
    ANALYTICAL METHODS, 2014, 6 (10) : 3261 - 3267
  • [38] 3D-printed, configurable, paper-based, and autonomous multi-organ-on-paper platforms
    Li, Hongbin
    Cheng, Feng
    Wang, Zixuan
    Li, Wanlu
    Antonio Robledo-Lara, Juan
    Zhang, Yu Shrike
    MOLECULAR SYSTEMS DESIGN & ENGINEERING, 2022, 7 (11) : 1538 - 1548
  • [39] 2D/3D tunable paper-based metamaterial antenna
    Taishi, Baiying
    Yating, Yang
    Yang, Jing
    Pang, Yachen
    Xu, Jianchun
    Bi, Ke
    CAILIAO GONGCHENG-JOURNAL OF MATERIALS ENGINEERING, 2024, 52 (10): : 189 - 196
  • [40] Inkjet printed microfluidic paper-based analytical device (μPAD) for glucose colorimetric detection in artificial urine
    Han Zhang
    Ethan Smith
    Wei Zhang
    Anhong Zhou
    Biomedical Microdevices, 2019, 21