Non-adiabatic capillary tube flow with isobutane

被引:38
|
作者
Melo, C [1 ]
Vieira, LAT
Pereira, RH
机构
[1] Univ Fed Santa Catarina, Dept Mech Engn, NVRA, BR-88040090 Florianopolis, SC, Brazil
[2] Embraco SA, BR-89219901 Joinville, SC, Brazil
关键词
capillary tube; isobutane; expansion device; heat exchanger;
D O I
10.1016/S1359-4311(02)00072-8
中图分类号
O414.1 [热力学];
学科分类号
摘要
This work reports the results of an experimental study on concentric capillary tube-suction line heat exchangers commonly used as expansion devices in household refrigerators and freezers. Heat exchanger performance (mass flow rate and suction line outlet temperature) with the hydrocarbon HC-600a was experimentally evaluated for a range of heat exchanger geometries and operating conditions. The tests were planned and performed following a statistically based methodology. Based on the resulting database empirical correlations were developed to predict the refrigerant mass flow rate and the suction line outlet temperature. (C) 2002 Elsevier Science Ltd. All rights reserved.