Analysis of differential artificial ageing of the adhesive interface produced by a two-step etch-and-rinse adhesive

被引:53
|
作者
Saboia, Vicente P. A. [2 ]
Silva, Francisco C. F. A. [2 ]
Nato, Fernando [3 ,4 ]
Mazzoni, Annalisa [3 ]
Cadenaro, Milena
Mazzotti, Giovanni [3 ]
Giannini, Marcelo [5 ]
Breschi, Lorenzo [1 ,6 ]
机构
[1] Univ Trieste, Unit Dent Sci & Biomat, Dept Biomed, Div Dent Sci & Biomat, I-34129 Trieste, Italy
[2] Univ Fed Ceara, Dept Restorat Dent, Fortaleza, Ceara, Brazil
[3] Univ Bologna, Dept SAU & FAL, Bologna, Italy
[4] Univ Carlo Bo, Dept SUNT, Urbino, Italy
[5] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Restorat Dent, Piracicaba, SP, Brazil
[6] Univ Bologna, CNR, IGM, IOR, Bologna, Italy
关键词
dentine; dentine-bonding agents; in vitro ageing techniques; RESIN-DENTIN BONDS; TERM WATER STORAGE; IN-VITRO; NANOLEAKAGE EXPRESSION; TEM ANALYSIS; DEGRADATION; STRENGTH; DURABILITY; COLLAGEN; CHLORHEXIDINE;
D O I
10.1111/j.1600-0722.2009.00665.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study was performed to evaluate the effects of different in vitro ageing techniques on the dentine-bonded interface produced by a two-step etch-and-rinse adhesive. Composite build-ups were bonded to sectioned human molars using XP BOND and cut into non-trimmed dentine-composite beams for microtensile testing. Beams were assigned to one of the following storage conditions: (i) artificial saliva, 24 h (control); (ii) 10% sodium hypochlorite (NaOCl), 1 h; (iii) 10% NaOCl, 3 h; (iv) 60,000 thermal cycles, 2 months; (v) artificial saliva, 2 months; (vi) 60,000 thermal cycles, 6 months; and (vii) artificial saliva, 6 months. Beams were then pulled until failure and bond strength was calculated. Additional specimens were examined to investigate interfacial nanoleakage expression. NaOCl solution significantly reduced bonding compared with the control (group 2 = group 3 < group 1); and thermocycling reduced the bond strength in comparison to specimens stored for the same time-period in artificial saliva (group 4 < group 5; group 6 < group 7). Artificial ageing affected bond strength only after 6 months of storage (group 7 < group 5 = group 1). Increased nanoleakage was found under all ageing conditions in comparison with controls. NaOCl solution is a rapid and reliable in vitro ageing method for examining the durability of the adhesive interface produced by two-step etch-and-rinse adhesive systems.
引用
收藏
页码:618 / 624
页数:7
相关论文
共 50 条
  • [1] Adhesion of a Two-step Etch-and-Rinse Adhesive on Collagen-depleted Dentin
    Saboia, Vicente P. A.
    Neto, Fernando
    Mazzoni, Annalisa
    Orsini, Giovanna
    Putignano, Angelo
    Giannini, Marcelo
    Breschi, Lorenzo
    [J]. JOURNAL OF ADHESIVE DENTISTRY, 2008, 10 (06): : 419 - 422
  • [2] Two-year clinical evaluation of proanthocyanidins added to a two-step etch-and-rinse adhesive
    de Souza, Lidiane Costa
    Rodrigues, Nara Sousa
    Cunha, Diana Araujo
    Feitosa, Victor Pinheiro
    Santiago, Sergio Lima
    Reis, Alessandra
    Loguercio, Alessandro Dourado
    Matos, Thalita de Paris
    Aragao Saboia, Vicente de Paulo
    Perdigao, Jorge
    [J]. JOURNAL OF DENTISTRY, 2019, 81 : 7 - 16
  • [3] Bond Strength of Two-Step Etch-and-Rinse Adhesive Systems to the Dentin of Primary and Permanent Teeth
    Ricci, Herica Adad
    Sanabe, Mariane Emi
    de Souza Costa, Carlos Alberto
    Hebling, Josimeri
    [J]. JOURNAL OF CLINICAL PEDIATRIC DENTISTRY, 2010, 35 (02) : 163 - 168
  • [4] Microtensile bond strength of two-step etch-and-rinse adhesive systems on sound and artificial caries-affected dentin
    Zanchi, Cesar Henrique
    Lund, Rafael Guerra
    Perrone, Luciana Rodrigues
    Ribeiro, Gladis Aver
    Burkert del Pino, Francisco Augusto
    Pinto, Marcia Bueno
    Demarco, Flavio Fernando
    [J]. AMERICAN JOURNAL OF DENTISTRY, 2010, 23 (03): : 152 - 156
  • [5] Two-year clinical performance of a two-step etch-and-rinse adhesive in non-carious cervical lesions
    Sandes Farias, David Cardoso
    Lopes, Guilherme Carpena
    Baratieri, Luiz Narciso
    [J]. CLINICAL ORAL INVESTIGATIONS, 2015, 19 (08) : 1867 - 1874
  • [6] Effect of chlorhexidine on bond strength of two-step etch-and-rinse adhesive systems to dentin of primary and permanent teeth
    Ricci, Herica Adad
    Sanabe, Mariane Emi
    de Souza Costa, Carlos Alberto
    Hebling, Josimeri
    [J]. AMERICAN JOURNAL OF DENTISTRY, 2010, 23 (03): : 128 - 132
  • [7] Comparison of dentin bond durability of a universal adhesive and two etch-and-rinse adhesive systems
    Kawazu, Mami
    Takamizawa, Toshiki
    Hirokane, Eizo
    Tsujimoto, Akimasa
    Tamura, Tomohiko
    Barkmeier, Wayne W.
    Latta, Mark A.
    Miyazaki, Masashi
    [J]. CLINICAL ORAL INVESTIGATIONS, 2020, 24 (08) : 2889 - 2897
  • [8] Comparison of dentin bond durability of a universal adhesive and two etch-and-rinse adhesive systems
    Mami Kawazu
    Toshiki Takamizawa
    Eizo Hirokane
    Akimasa Tsujimoto
    Tomohiko Tamura
    Wayne W. Barkmeier
    Mark A. Latta
    Masashi Miyazaki
    [J]. Clinical Oral Investigations, 2020, 24 : 2889 - 2897
  • [9] MMP-2 assay within the hybrid layer created by a two-step etch-and-rinse adhesive: Biochemical and immunohistochemical analysis
    Mazzoni, Annalisa
    Carrilho, Marcela
    Papa, Veronica
    Tjaderhane, Leo
    Gobbi, Pietro
    Nucci, Cesare
    Di Lenarda, Roberto
    Mazzotti, Giovanni
    Tay, Franklin R.
    Pashley, David H.
    Breschi, Lorenzo
    [J]. JOURNAL OF DENTISTRY, 2011, 39 (07) : 470 - 477
  • [10] Effect of Dimethyl Sulfoxide Primer Application Before a Two-Step Etch-and-Rinse Adhesive on the Microtensile Bond Strength and Nanoleakage
    Ismail, Omar Abdelaziz
    Hassanein, Olfat Elsayed
    Hafez, Randa
    Mamdouh, Mai
    [J]. JOURNAL OF INTERNATIONAL ORAL HEALTH, 2024, 16 (03): : 246 - 252