Bond Strength of Two-Step Etch-and-Rinse Adhesive Systems to the Dentin of Primary and Permanent Teeth

被引:8
|
作者
Ricci, Herica Adad
Sanabe, Mariane Emi
de Souza Costa, Carlos Alberto [2 ]
Hebling, Josimeri [1 ]
机构
[1] Univ Estadual Paulista, UNESP, Fac Odontol Araraquara, Dept Orthodont & Pediat Dent,Araraquare Sch Dent, BR-14801903 Araraquara, SP, Brazil
[2] Univ Estadual Paulista, UNESP, Dept Physiol & Pathol, Araraquara Sch Dent, BR-14801903 Araraquara, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Dentin-Bonding Agents; Dentin; Tensile Strength; Tooth; Deciduous; Dentition; Permanent; IN-VITRO; DEGRADATION; SOUND; TIME;
D O I
10.17796/jcpd.35.2.958893530534m503
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: The purpose of this study was to compare the immediate microtensile bond strength (mu TBS) of two-step etch-and-rinse adhesive systems to the dentin of primary and permanent teeth. Study Design: Non-carious human teeth (12 primary molars and 12 premolars) were assigned to 3 groups according to the adhesive system. The adhesive systems were applied to flat superficial coronal dentin surfaces etched with phosphoric acid and composite resin blocks were built up. The teeth were sectioned to produce beam-shaped specimens with 0.81 mm(2) cross-sectional area subjected to mu TBS testing. mu TBS data were analyzed statistically by ANOVA and Tukey's test (a= 0.05). Results: The adhesive systems produced statistically similar mean mu TBS to each other (p> 0.05) and no significant differences (p> 0.05) were found when the same material was applied to primary or permanent tooth dentin. The mean mu TBS values (MPa) obtained were: Prime & Bond NT: 41.7 +/- 14.4 (permanent) and 40.8 +/- 13.4 (primary); Single Bond: 42.9 +/- 8.6 (permanent) and 41.4 +/- 11.9 (primary); Excite DSC: 46.3 +/- 11.3 (permanent teeth) and 43.4 +/- 12.0 (primary). Conclusion: There was no difference in the immediate mu TBS of two-step etch-and-rinse adhesive systems when applied to the dentin of primary and permanent teeth.
引用
收藏
页码:163 / 168
页数:6
相关论文
共 50 条
  • [1] Effect of chlorhexidine on bond strength of two-step etch-and-rinse adhesive systems to dentin of primary and permanent teeth
    Ricci, Herica Adad
    Sanabe, Mariane Emi
    de Souza Costa, Carlos Alberto
    Hebling, Josimeri
    [J]. AMERICAN JOURNAL OF DENTISTRY, 2010, 23 (03): : 128 - 132
  • [2] Microtensile bond strength of two-step etch-and-rinse adhesive systems on sound and artificial caries-affected dentin
    Zanchi, Cesar Henrique
    Lund, Rafael Guerra
    Perrone, Luciana Rodrigues
    Ribeiro, Gladis Aver
    Burkert del Pino, Francisco Augusto
    Pinto, Marcia Bueno
    Demarco, Flavio Fernando
    [J]. AMERICAN JOURNAL OF DENTISTRY, 2010, 23 (03): : 152 - 156
  • [3] Effect of desensitizing agents on the microtensile bond strength of two-step etch-and-rinse adhesives to dentin
    Cortiano, Fernanda M.
    Rached, Rodrigo N.
    Mazur, Rui F.
    Vieira, Sergio
    Freire, Andrea
    de Souza, Evelise M.
    [J]. EUROPEAN JOURNAL OF ORAL SCIENCES, 2016, 124 (03) : 309 - 315
  • [4] Adhesion of a Two-step Etch-and-Rinse Adhesive on Collagen-depleted Dentin
    Saboia, Vicente P. A.
    Neto, Fernando
    Mazzoni, Annalisa
    Orsini, Giovanna
    Putignano, Angelo
    Giannini, Marcelo
    Breschi, Lorenzo
    [J]. JOURNAL OF ADHESIVE DENTISTRY, 2008, 10 (06): : 419 - 422
  • [5] Comparison of dentin bond durability of a universal adhesive and two etch-and-rinse adhesive systems
    Kawazu, Mami
    Takamizawa, Toshiki
    Hirokane, Eizo
    Tsujimoto, Akimasa
    Tamura, Tomohiko
    Barkmeier, Wayne W.
    Latta, Mark A.
    Miyazaki, Masashi
    [J]. CLINICAL ORAL INVESTIGATIONS, 2020, 24 (08) : 2889 - 2897
  • [6] Comparison of dentin bond durability of a universal adhesive and two etch-and-rinse adhesive systems
    Mami Kawazu
    Toshiki Takamizawa
    Eizo Hirokane
    Akimasa Tsujimoto
    Tomohiko Tamura
    Wayne W. Barkmeier
    Mark A. Latta
    Masashi Miyazaki
    [J]. Clinical Oral Investigations, 2020, 24 : 2889 - 2897
  • [7] Degradation of resin-dentin bonds of etch-and-rinse adhesive system to primary and permanent teeth
    Lenzi, Tathiane Larissa
    Maxnuck Soares, Fabio Zovico
    Rocha, Rachel de Oliveira
    [J]. BRAZILIAN ORAL RESEARCH, 2012, 26 (06) : 511 - 515
  • [8] Self-etch or etch-and-rinse mode did not affect the microshear bond strength of a universal adhesive to primary dentin
    Thanaratikul, Benjaporn
    Santiwong, Busayarat
    Harnirattisai, Choltacha
    [J]. DENTAL MATERIALS JOURNAL, 2016, 35 (02) : 174 - 179
  • [9] Microshear bond strength and interfacial morphology of etch-and-rinse and self-etch adhesive systems to superficial and deep dentin
    Yousry, Mai Mahmoud
    ElNaga, Albeer Abo
    Hafez, Randa M.
    El-Badrawy, Wafa
    [J]. QUINTESSENCE INTERNATIONAL, 2011, 42 (09): : E96 - E106
  • [10] Effect of Dimethyl Sulfoxide Primer Application Before a Two-Step Etch-and-Rinse Adhesive on the Microtensile Bond Strength and Nanoleakage
    Ismail, Omar Abdelaziz
    Hassanein, Olfat Elsayed
    Hafez, Randa
    Mamdouh, Mai
    [J]. JOURNAL OF INTERNATIONAL ORAL HEALTH, 2024, 16 (03): : 246 - 252