SIGNIFICANCE OF PREOPERATIVE EXTERNAL LIMITING MEMBRANE HEIGHT ON VISUAL PROGNOSIS IN PATIENTS UNDERGOING MACULAR HOLE SURGERY

被引:15
|
作者
Geenen, Caspar [1 ]
Murphy, Declan C. [2 ]
Sandinha, Maria T. [1 ]
Rees, Jon [3 ]
Steel, David H. W. [1 ,2 ]
机构
[1] Sunderland Eye Infirm, Queen Alexandra Rd, Sunderland SR2 9HP, Tyne & Wear, England
[2] Newcastle Univ, Inst Med Genet, Newcastle Upon Tyne, Tyne & Wear, England
[3] Univ Sunderland, Sch Psychol, Fac Hlth Sci & Wellbeing, Sunderland, Durham, England
来源
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES | 2019年 / 39卷 / 07期
关键词
external limiting membrane; height; outcome; outer retina; macular hole; minimum linear diameter; visual acuity; width; OPTICAL COHERENCE TOMOGRAPHY; FOVEA-CENTRALIS; OUTER SEGMENT; THICKNESS; DEFECT; CLASSIFICATION; HYPOTHESES; TRACTION; FEATURES; CLOSURE;
D O I
10.1097/IAE.0000000000002137
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate the association between the vertical elevation of the external limiting membrane (ELM) and visual outcome in patients undergoing surgery for idiopathic full-thickness macular hole. Methods: Retrospective observational study of a consecutive cohort of patients undergoing vitrectomy to treat macular hole. The greatest vertical height of the central ELM above the retinal pigment epithelium (ELM height) was measured on spectral domain optical coherence tomography preoperatively. The relationship of ELM height to other preoperative and postoperative variables, including macular hole width and height, and visual acuity was analyzed. Results: Data from 91 eyes of 91 patients who had undergone successful hole closure were included. The mean ELM height was 220 mu m (range 100-394). There were significant correlations between the ELM height and the diameter of the hole, hole height, and worsening preoperative visual acuity. For holes less than 400 mu m in width, better postoperative visual acuity was significantly predicted by a lower ELM height. Conclusion: The ELM height varies widely in idiopathic macular hole. It is higher in eyes where the hole is wider and also when the hole itself is higher. For holes of less than 400 mu m in width, a lower ELM height is a strong independent predictor of a good postoperative outcome.
引用
收藏
页码:1392 / 1398
页数:7
相关论文
共 50 条
  • [21] HYPERREFLECTIVE EXTERNAL LIMITING MEMBRANES AFTER SUCCESSFUL MACULAR HOLE SURGERY
    Oh, In Kyung
    Oh, Jaeryung
    Yang, Sun Mo
    Ahn, Soh Eun
    Kim, Seong-Woo
    Huh, Kuhl
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2012, 32 (04): : 760 - 766
  • [22] Effect of indocyanine green dye on the visual outcomes in macular hole surgery with internal limiting membrane peeling
    Horio, N
    Oya, Y
    Sugino, T
    Sakurai, S
    Abematsu, N
    Shimada, Y
    Horiguchi, M
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U335 - U335
  • [23] Functional outcome and macular index in macular hole patients who underwent surgery with internal limiting membrane removal
    Diniz, Jose Ricardo
    da Luz, Allan Cezar
    Carvalho, Kleper
    Fontes, Vladimir
    Arcoverde, Ana Lucia
    Santos Cavalcante Melo, Maria Cecilia
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2008, 71 (02) : 182 - 186
  • [24] Triamcinolone assisted internal limiting membrane peeling in macular hole surgery
    Ahmad, OR
    Wickens, JC
    Blinder, KJ
    Shah, GK
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [25] Localization of the Internal Limiting Membrane Flap After Macular Hole Surgery
    Morozova, Christine
    Morozov, Andy
    Kamen, Dan
    Zhang, Jin
    Favale, Rossella
    Walsh, Mark
    Boscia, Francesco
    Boyer, David S.
    Tabandeh, Homayoun
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [26] Floating flap of internal limiting membrane in myopic macular hole surgery
    Kenji Yamashiro
    Eri Kinoshita-Nakano
    Toru Ota
    Yoko Jingami
    Isao Nakata
    Hisako Hayashi
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2018, 256 : 693 - 698
  • [27] Floating flap of internal limiting membrane in myopic macular hole surgery
    Yamashiro, Kenji
    Kinoshita-Nakano, Eri
    Ota, Toru
    Jingami, Yoko
    Nakata, Isao
    Hayashi, Hisako
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2018, 256 (04) : 693 - 698
  • [28] Macular hole surgery with and without internal limiting membrane peeling - Discussion
    Margherio, RR
    OPHTHALMOLOGY, 2000, 107 (10) : 1948 - 1949
  • [29] Inverted macular hole edges following an inverted internal limiting membrane transplantation surgery for large macular hole
    Nagesha, C. K.
    Baskaran, Prabu
    Dhoble, Pankaja
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2018, 66 (02) : 293 - 294
  • [30] Is it necessary to cover the macular hole with the inverted internal limiting membrane flap in macular hole surgery? A case report
    Chung-yee Chung
    David Sai-hung Wong
    Kenneth Kai-wang Li
    BMC Ophthalmology, 15