Awake intubation with the Bonfils fibrescope in patients with difficult airway

被引:17
|
作者
Corbanese, Ulisse [1 ]
Possamai, Clemente [1 ]
机构
[1] Osped S Maria dei Battuti, Dept Anesthesia & Intens Care, I-31015 Conegliano, Italy
关键词
fibre optic technology; intubation; intratracheal instrumentation; TRACHEAL INTUBATION; LARYNGOSCOPY; MANAGEMENT;
D O I
10.1097/EJA.0b013e32832c6076
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background In the majority of patients with difficult airways intubated using the Bonfils fibrescope, intubations have been performed under general anaesthesia. Our aim is to report a consecutive series of intubations on awake patients with anticipated difficult airways, performed using the Bonfils fibrescope. Methods A prospective case series of intubations performed with the Bonfils fibrescope by a single anaesthesiologist is described in this article. Thirty patients with anticipated difficult airways were included (11 of them after failed intubations with Macintosh laryngoscope). Awake intubation attempts were performed under mild sedation and topical anaesthesia (with or without transcricothyroid membrane injection). The effectiveness was assessed in terms of success rate, number of attempts, difficulties, and complications encountered. Results Overall, awake intubation was successful in 29 out of 30 patients (96.6%). In the predicted difficult airway group, 19 patients with anticipated difficult airways were included. Awake intubation with Bonfils fibrescope was successful in 18 out of 19 patients (94.7%). In the known failed intubation group, 11 patients were included; the airways of five of them had already been managed with flexible fibrescope. All patients were successfully intubated awake with the Bonfils fibrescope. Conclusions Our findings confirm that awake intubation with the Bonfils fibrescope is well tolerated and highly successful, even if performed by operators in training, and strengthen the evidence that the Bonfils fibrescope is one of the most promising devices to assist intubation in patients with difficult airways. Eur J Anaesthesiol 26:837-841 (C) 2009 European Society of Anaesthesiology.
引用
收藏
页码:837 / 841
页数:5
相关论文
共 50 条
  • [31] AWAKE PATIENT WITH A DIFFICULT AIRWAY: INTUBATION WITH THE AIRTRAQ LARYNGOSCOPE
    De Blas Garcia, M.
    Ortega Orejon, R.
    Hernandez Gancedo, Ma C.
    Rodriguez Seguin, Ma I.
    [J]. REVISTA ESPANOLA DE ANESTESIOLOGIA Y REANIMACION, 2010, 57 (08): : 540 - 541
  • [32] Awake fibrecapnic intubation: a novel technique for intubation in head and neck cancer patients with a difficult airway
    Huitink, JM
    Buitelaar, DR
    Schutte, PFE
    [J]. ANAESTHESIA, 2006, 61 (05) : 449 - 452
  • [33] The difficult paediatric airway:: a new method of intubation using the laryngeal mask airway™, Cook® airway exchange catheter and tracheal intubation fibrescope
    Thomas, PB
    Parry, MG
    [J]. PAEDIATRIC ANAESTHESIA, 2001, 11 (05): : 618 - 621
  • [34] Awake video laryngoscopy aided intubation as an alternative to awake fiberoptic intubation in a patient with difficult airway
    Kumar, Niranjan
    Rajan, Sunil
    Kumar, Lakshmi
    [J]. JOURNAL OF ANAESTHESIOLOGY CLINICAL PHARMACOLOGY, 2023, 39 (01) : 153 - 154
  • [35] Awake Intubation with Video Laryngoscope and Fiberoptic Bronchoscope in Difficult Airway Patients Reply
    Fiadjoe, John E.
    Litman, Ronald S.
    [J]. ANESTHESIOLOGY, 2013, 118 (02) : 463 - 463
  • [36] Pentax-AWS videolaryngoscope for awake nasotracheal intubation in patients with a difficult airway
    Xue, F. S.
    Xiong, J.
    Yuan, Y. J.
    Wang, Q.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2010, 104 (04) : 505 - 505
  • [37] Awake tracheal intubation using the SensaScopeTM in 13 patients with an anticipated difficult airway
    Biro, P.
    [J]. ANAESTHESIA, 2010, 65 (08) : 860 - 861
  • [38] Awake tracheal intubation using the Sensascope™ in 13 patients with an anticipated difficult airway
    Greif, R.
    Kleine-Brueggeney, M.
    Theiler, L.
    [J]. ANAESTHESIA, 2010, 65 (05) : 525 - 528
  • [39] Awake intubation using Pentax Airway Scope as an alternative to awake fiberoptic intubation in management of anticipated difficult tracheal intubation in major burn patients
    Fayolle-Pivot, L.
    Magnin, C.
    Tissot, S.
    Bertin-Maghit, M.
    Allaouchiche, B.
    [J]. ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 2013, 32 (05): : 355 - 357
  • [40] Use of the Bonfils intubating fibrescope in a baby with a severely compromised airway
    Krishnan, Priya L.
    Thiessen, Bernd H.
    [J]. PEDIATRIC ANESTHESIA, 2013, 23 (07) : 670 - 672