Evaluation of DPC Immulite 2000® Toxoplasma Quantitative IgG/IgM Kits for Automated Toxoplasmosis Serology with Immulite 2000®

被引:8
|
作者
Robert-Gangneux, Florence [1 ,2 ]
Bourhis, Chantal [3 ]
Chevrier, Sylviane [1 ]
Gangneux, Jean-Pierre [1 ,2 ]
机构
[1] CHU Rennes, Lab Parasitol Mycol, F-35033 Rennes, France
[2] Univ Rennes 1, Fac Med, Serv Parasitol, IFR 140, Rennes, France
[3] Hop Broussais, Med Biol Lab, St Malo, France
关键词
toxoplasmosis; serological diagnosis; ELISA; antibody; TORCH screening; POLYMERASE-CHAIN-REACTION; EARLY NEONATAL DIAGNOSIS; CONGENITAL TOXOPLASMOSIS; PRENATAL-DIAGNOSIS; IMMUNOGLOBULIN-M; FOLLOW-UP; GONDII; ANTIBODIES; ASSAY; PERFORMANCE;
D O I
10.1002/jcla.20338
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
In this study, we evaluated a new immunoassay for the automated detection of anti-toxoplasma IgG and IgM with Immulite 2000 (R) (DPC-Siemens, La Garenne-Colombes, France). We tested 280 sera from 112 patients with past infection (PI), 40 PI with residual IgM, 75 seronegatives, 16 infants (31 sera) monitored for neonatal screening of congenital toxoplasmosis, and 13 patients with recent seroconversion (SC) (22 sequential sera). Detection sensitivity and specificity for IgG were 99 and 100%, respectively. IgG titers obtained with Immulite 2000 (R) were higher than with Vidas (R) (BioMerieux, Marcy l'Etoile, France) and Access (R) (Beckman-Coulter, Villepinte, France) (paired Wilcoxon test z = 4.44 and z = 3.67, respectively, P < 0.001). IgM specificity was 100%. Detection sensitivity for IgM was 100% in the SC group, 86% in congenitally infected infants, and 75% in PI with persistent IgM. IgM detection seemed less prolonged in time than with the IgM Access (R) and ISAGA (R) IgM techniques. J. Clin. Lab. Anal. 23:336-340, 2009. (C) 2009 Wiley-Liss, Inc.
引用
收藏
页码:336 / 340
页数:5
相关论文
共 50 条
  • [21] EVALUATION OF AUTOMATED CHEMILUMINESCENT METHOD FOR HGH ASSAY - HGH IMMULITE - DPC
    DEMEDICI, C
    BERGAMASCHI, B
    RONDINELLI, E
    CASTAGNA, G
    CLINICAL CHEMISTRY, 1995, 41 (06) : S198 - S198
  • [22] Allergen specific IgG4 detection on the IMMULITE® 2000 System
    Chuang, T.
    Maldonado, S.
    Kubota, H.
    Hovanec-Burns, D.
    ALLERGY, 2008, 63 : 225 - 225
  • [23] Comparison of SIEMENS IMMULITE® 2000 with GenBio immunowell EIA for detection of antibodies to EBV VCA IgG & IgM and EBNA IgG
    Lee, C.
    Conde, M.
    Chuu, C.
    Ghadessi, M.
    Lei, J.
    Sustarsic, D.
    CLINICAL CHEMISTRY, 2007, 53 (06) : A58 - A59
  • [24] Comparative study of DPC Immulite 2000 with DPC Immulite for FT4, intact PTH, Prolactin, Progesterone, DHEA-SO4 and Estradiol.
    Oureshi, A
    CLINICAL CHEMISTRY, 2002, 48 (06) : A133 - A133
  • [25] Automated measurement of plasma homocysteine on DPC Immulite 2000: comparison with measurement carried out on Abbott IMX Apparatus
    Quillard, M
    Berthe, MC
    Sauger, F
    Lavoinne, A
    ANNALES DE BIOLOGIE CLINIQUE, 2003, 61 (06) : 699 - 704
  • [26] Evaluation of two new automated assays for hepatitis B virus surface antigen (HBsAg) detection: IMMULITE HBsAg and IMMULITE 2000 HBsAg
    Weber, B
    Dengler, T
    Berger, A
    Doerr, HW
    Rabenau, H
    JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (01) : 135 - 143
  • [27] A two-center international evaluation of the Immulite 2000 automated serum gastrin assay
    Eastvold, ML
    Wallinder, HW
    Preissner, CM
    Singh, RJ
    Löwbeer, C
    Grebe, SKG
    CLINICAL BIOCHEMISTRY, 2006, 39 (04) : 387 - 390
  • [28] Prevalence of hyperprolactinaemia due to macroprolactin in a DGH using the DPC immulite 2000 PRL assay
    Slater, J
    Tilbrook, L
    Fahie-Wilson, M
    CLINICA CHIMICA ACTA, 2005, 355 : S261 - S262
  • [29] Automated chemiluminescent immunoassays for pregnancy-associated plasma protein A (PAPP-A) on the IMMULITE® and IMMULITE® 2000 analyzers.
    Bostanian, Z
    Hall, G
    Whitters, E
    Lei, JD
    Pregger, K
    Sustarsic, D
    Unver, E
    El Shami, AS
    CLINICAL CHEMISTRY, 2003, 49 (06) : A29 - A29
  • [30] Development and analytical performance of the IMMULITE® 2000 allergen-specific IgG assay
    Chuang, T.
    Walker, M.
    Rouhani, R.
    Hoang, A.
    Hovanec-Burns, D.
    ALLERGY, 2007, 62 : 234 - 234