Guided bone tissue regeneration using a hollow calcium phosphate based implant in a critical size rabbit radius defect

被引:5
|
作者
Torbjorn, Mellgren [1 ]
Amela, Trbakovic [2 ]
Andreas, Thor [2 ]
Stina, Ekman [3 ]
Cecilia, Ley [3 ]
Caroline, Ohman-Magi [1 ]
Petra, Hammarstrom Johansson [4 ]
Marianne, Jensen-Waern [5 ]
Patricia, Hedenqvist [5 ]
机构
[1] Uppsala Univ, Mat Med Grp, Div Appl Mat Sci, Dept Mat Sci & Engn, POB 534, S-75121 Uppsala, Sweden
[2] Uppsala Univ, Dept Surg Sci Plast & Oral & Maxillofacial Surg, S-75185 Uppsala, Sweden
[3] Swedish Univ Agr Sci, Div Pathol, Dept Biomed Sci & Vet Publ Hlth, POB 7028, S-75007 Uppsala, Sweden
[4] Univ Gothenburg, Dept Prosthodont Dental Mat Sci, Inst Odontol, Sahlgrenska Acad, POB 450, S-40530 Gothenburg, Sweden
[5] Swedish Univ Agr Sci, Dept Clin Sci, POB 7054, S-75007 Uppsala, Sweden
基金
瑞典研究理事会;
关键词
3D printing; bone augmentation; bone substitute; long bone; in vivo;
D O I
10.1088/1748-605X/abde6f
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Long bone fractures are common and sometimes difficult to treat. Autologous bone (AB), bovine bone and calcium phosphates are used to stimulate bone growth with varying results. In the present study, a calcium phosphate cement (CPC) that previously showed promising grafting capabilities was evaluated for the first time in a long bone defect. A radius defect of 20 mm was created in 20 rabbits. The defect was filled by either a hollow CPC implant that had been manufactured as a replica of a rabbit radius through indirect 3D printing, or by particulate AB as control. Defect filling and bone formation was evaluated after 12 weeks by combining micro computed tomography (mu CT) and scoring of 3D images, together with histomorphometry and histology. The mu CT and histomorphometric evaluations showed a similar amount of filling of the defect (combining graft and bone) between the CPC and AB group, but the scoring of 3D images showed that the filling in the CPC group was significantly larger. Histologically the AB graft could not be distinguished from the new bone. The AB treated defects were found to be composed of more bone than the CPC group, including reorganised cancellous and cortical bone. Both the CPC and AB material was associated with new bone formation, also in the middle of the defect, which could result in closing of the otherwise critically sized gap. This study shows the potential for an indirectly 3D printed implant in guided bone regeneration in critically sized long bone defects.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Retrograde Study Using Radiographic Comparison of Bone Fill Observed after Guided Tissue Regeneration by the Type of Periodontal Bone Defect
    Do, Woo-Seok
    Kim, Yong-Gun
    Suh, Jo-Young
    Kim, Jin-Wook
    Lee, Jae-Mok
    APPLIED SCIENCES-BASEL, 2024, 14 (01):
  • [42] Amorphous polyphosphate/amorphous calcium carbonate implant material with enhanced bone healing efficacy in a critical-size defect in rats
    Wang, Xiaohong
    Ackermann, Maximilian
    Wang, Shunfeng
    Tolba, Emad
    Neufurth, Meik
    Feng, Qingling
    Schroeder, Heinz C.
    Mueller, Werner E. G.
    BIOMEDICAL MATERIALS, 2016, 11 (03)
  • [43] Guided bone regeneration of calcium phosphate-coated and strontium ranelate-doped titanium mesh in a rat calvarial defect model
    Byeon, Seon Mi
    Bae, Tae Sung
    Lee, Min Ho
    Ahn, Seung Geun
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2024, 54 (05): : 336 - 348
  • [44] Staged implant placement after defect regeneration using biphasic calcium phosphate materials with different surface topographies in a minipig model
    Mihatovic, I
    Schwarz, F.
    Obreja, K.
    Becker, J.
    Sader, R.
    Dard, M.
    John, G.
    CLINICAL ORAL INVESTIGATIONS, 2020, 24 (09) : 3289 - 3298
  • [45] Staged implant placement after defect regeneration using biphasic calcium phosphate materials with different surface topographies in a minipig model
    I. Mihatovic
    F. Schwarz
    K. Obreja
    J. Becker
    R. Sader
    M. Dard
    G. John
    Clinical Oral Investigations, 2020, 24 : 3289 - 3298
  • [46] Degradation and silicon excretion of the calcium silicate bioactive ceramics during bone regeneration using rabbit femur defect model
    Kaili Lin
    Yong Liu
    Hai Huang
    Lei Chen
    Zhen Wang
    Jiang Chang
    Journal of Materials Science: Materials in Medicine, 2015, 26
  • [47] Degradation and silicon excretion of the calcium silicate bioactive ceramics during bone regeneration using rabbit femur defect model
    Lin, Kaili
    Liu, Yong
    Huang, Hai
    Chen, Lei
    Wang, Zhen
    Chang, Jiang
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2015, 26 (06)
  • [48] Improved bone regeneration using collagen-coated biphasic calcium phosphate with high porosity in a rabbit calvarial model
    Seo, Seung-Jun
    Kim, Yong-Gun
    BIOMEDICAL MATERIALS, 2021, 16 (01)
  • [49] In vitro and in vivo evaluation of novel Tadalafil/β-TCP/Collagen scaffold for bone regeneration: A rabbit critical-size calvarial defect study
    Soufdoost, Reza Sayyad
    Yazdanian, Mohsen
    Tahmasebi, Elaheh
    Yazdanian, Alireza
    Tebyanian, Hamid
    Karami, Ali
    Nourani, Mohammad Reza
    Panahi, Yunes
    BIOCYBERNETICS AND BIOMEDICAL ENGINEERING, 2019, 39 (03) : 789 - 796
  • [50] Transplantation of human mesenchymal stem cells in a non-autogenous setting for bone regeneration in a rabbit critical-size defect model
    Niemeyer, P.
    Szalay, K.
    Luginbuhl, R.
    Suedkamp, N. P.
    Kasten, P.
    ACTA BIOMATERIALIA, 2010, 6 (03) : 900 - 908