Detection of specific antinuclear reactivities in patients with negative anti-nuclear antibody immunofluorescence screening tests

被引:1
|
作者
Hoffman, IEA [1 ]
Peene, I [1 ]
Veys, EM [1 ]
De Keyser, F [1 ]
机构
[1] Ghent Univ Hosp, Dept Rheumatol, B-9000 Ghent, Belgium
关键词
D O I
暂无
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: For detection of anti-nuclear antibodies (ANAs) and antibodies to extractable nuclear antigens (ENAs), samples frequently are screened with indirect immunofluorescence (IIF); further determination of anti-ENA antibodies is performed only when the result is positive. However, because anti-ENA reactivities are found in samples with low fluorescence intensities, we determined anti-ENA antibodies in samples with negative IIF and thus calculated the sensitivity of IIF for specific ANAs. Methods: We collected 494 samples consecutively referred by rheumatologists for routine ANA testing. IIF on HEp-2 and HEp-2000 (HEp-2 cells transfected with Ro60 cDNA) and line immunoassay (LIA) for the detection of specific ANAs were performed on all samples. Results: Fluorescence intensities and patterns on HEp-2 were strongly correlated with those on HEp-2000 [Spearman rho = 0.852 (P <0.001) and 0.838 (P <0.001), respectively]. Sixty-eight of 494 samples were positive on LIA, of which only 72% (confidence interval, 68-76%) were detected with HEp-2 and 75% (confidence interval, 70-78%) with HEp-2000. Of 291 samples negative on both substrates, 12 were positive on LIA. Connective tissue diseases were diagnosed in four of these patients and suspected in at least three others. Conclusion: The HEp-2 and HEp-2000 substrates perform comparably for fluorescence intensities and patterns and for detecting specific ANAs, but some patients with negative IIF show reactivity on LIA. We recommend testing for fine reactivities, regardless of the IIF result, when the clinical suspicion for rheumatic connective tissue disease is high. (C) 2002 American Association for Clinical Chemistry.
引用
收藏
页码:2171 / 2176
页数:6
相关论文
共 50 条
  • [31] Guidelines for clinical use of the antinuclear antibody test and tests for specific autoantibodies to nuclear antigens
    Kavanaugh, A
    Tomar, R
    Reveille, J
    Solomon, DH
    Homburger, HA
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 2000, 124 (01) : 71 - 81
  • [32] CHILDHOOD SYSTEMIC LUPUS-ERYTHEMATOSUS WITH NEGATIVE ANTI-NUCLEAR ANTIBODY-TEST
    GILLESPIE, JP
    LINDSLEY, CB
    LINSHAW, MA
    RICHARDSON, WP
    JOURNAL OF PEDIATRICS, 1981, 98 (04): : 578 - 581
  • [33] Evaluation of anti-dsDNA antibodies in anti-nuclear antibody positive omani patients
    Alnaqdy, Adel
    Al-Busaidy, Juma
    Hasson, Batool
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2007, 23 (02) : 211 - 215
  • [34] Anti-nuclear antibody detection in cryoprecipitates: Distinctive patterns in hepatitis C virus-infected patients
    Basile, Umberto
    Gulli, Francesca
    Torti, Eleonora
    De Matthaeis, Nicoletta
    Colacicco, Luigi
    Cattani, Paola
    Rapaccini, Gian Lodovico
    DIGESTIVE AND LIVER DISEASE, 2015, 47 (01) : 50 - 56
  • [35] Retrospective comparison of anti-nuclear antibody screening results reported by different referral laboratories
    Sohn, Kun-Young
    Kamel, Mona
    CLINICAL BIOCHEMISTRY, 2015, 48 (15) : 1006 - 1006
  • [36] Retrospective evaluation of "Rods and Rings" pattern detected in the anti-nuclear antibody (ANA) indirect immunofluorescence (IIF) test
    Inal, Nese
    Kurumanastirli, Berke
    Taskinoglu, Tutku
    Duran, Alev Cetin
    Togay, Alper
    Sariguzel, Fatma Mutlu
    Kasifoglu, Nilgun
    Soylu, Mehmet
    Dogan, Yavuz
    Us, Ebru
    Saribas, Zeynep
    Kaklikkaya, Nese
    Sener, Burcin
    FRONTIERS IN IMMUNOLOGY, 2024, 15
  • [37] Clinical Significance of Dense Fine Speckled Pattern in Anti-nuclear Antibody Test using Indirect Immunofluorescence Method
    Kang, So Young
    Lee, Woo-In
    KOREAN JOURNAL OF LABORATORY MEDICINE, 2009, 29 (02): : 145 - 151
  • [38] Serum Anti-Nuclear Antibodies and their patterns on immunofluorescence in patients with joint pain from Lahore, Pakistan
    Khan, Muhammad Daood
    Mubarak, Bushra
    Waheed, Kainat
    Munir, Iqra
    ADVANCEMENTS IN LIFE SCIENCES, 2022, 9 (03): : 318 - 322
  • [39] Screening for Specific Antinuclear Antibodies Using an Artificial Intelligence-enabled Antinuclear Antibody HEp-2 Substrate by Indirect Immunofluorescence Assay
    Vanderboom, Patrick
    Dasari, Surendra
    Tebo, Anne
    Snyder, Melissa
    Duarte-Garcia, Ali
    ARTHRITIS & RHEUMATOLOGY, 2023, 75 : 1709 - 1710
  • [40] Detection of anti-nuclear antibodies by indirect immunofluorescence on HEp-2 cells: setting the appropriate screening dilution for the diagnosis of autoimmune rheumatic diseases
    Brito, Fabiano de Almeida
    Eloi Santos, Silvana Maria
    Ferreira, Gilda Aparecida
    Pedrosa, William
    Gradisse, Janaina
    Costa, Lara Cristina
    Figueiredo Neves, Suzane Pretti
    REVISTA BRASILEIRA DE REUMATOLOGIA, 2014, 54 (01) : 13 - 20