摘要
The aim of this Study was to develop a new X ray and gamma ray monitor using the CdZnTe semiconductor detector, which has high sensitivity at room temperature. The pulse height spectra and the detection efficiencies of a 10 mm X 10 mm by 2 mm thick CdZnTe detector were measured in the energy range of 10 keV to 1.8 MeV by using monoenergetic X ray and gamma ray sources. The measured results showed very good agreement with the results calculated using the EGS4 Monte Carlo code taking into account the charge collection efficiency in the detector. By using two CZT detectors of 10 mm X 10 mm X 2 nun and 3 mm X 3 mm X 2 mm coupled with a filter, the weighted sum of a few energy channels with different cut-off-energies was finally found to achieve a flat energy response with an equivalent dose (counts per muSv) within +/-30% or +/-10% deviation.
引用
收藏
页码:77 / 80
页数:4
相关论文
共 50 条
  • [31] Preparation of indium tin oxide contact to n-CdZnTe gamma-ray detector
    Li, Leqi
    Xu, Yadong
    Zhang, Binbin
    Wang, Aoqiu
    Dong, Jiangpeng
    Yu, Hui
    Jie, Wanqi
    APPLIED PHYSICS LETTERS, 2018, 112 (11)
  • [32] Distribution of the high resistivity region in CdZnTe and its effects on gamma-ray detector performance
    S. Terterian
    M. Chu
    D. Ting
    Journal of Electronic Materials, 2004, 33 : 640 - 644
  • [33] Distribution of the high resistivity region in CdZnTe and its effects on gamma-ray detector performance
    Terterian, S
    Chu, M
    Ting, D
    JOURNAL OF ELECTRONIC MATERIALS, 2004, 33 (06) : 640 - 644
  • [34] A three-dimensional model of CdZnTe gamma-ray detector and its experimental validation
    Mathy, F
    Glière, A
    d'Aillon, EG
    Massé, P
    Picone, M
    Tabary, J
    Verger, L
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (05) : 2419 - 2426
  • [35] Direct measurement of mammographic x-ray spectra using a CdZnTe detector
    Matsumoto, M
    Yamamoto, A
    Honda, I
    Taniguchi, A
    Kanamori, H
    MEDICAL PHYSICS, 2000, 27 (07) : 1490 - 1502
  • [36] The development of better gamma-ray detector arrays
    Bazzacco, D
    INTERNATIONAL SYMPOSIUM ON NUCLEAR STRUCTURE PHYSICS: CELEBRATING THE CAREER OF PETER VON BRENTANO, 2001, : 287 - 292
  • [37] Development of an MeV gamma-ray imaging detector
    Takeda, A
    Kubo, H
    Miuchi, K
    Nagayoshi, T
    Okada, Y
    Orito, R
    Takada, A
    Tanimori, T
    Ueno, M
    Bouianov, O
    Bouianov, M
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (05) : 2140 - 2144
  • [38] Development of a direction finding gamma-ray detector
    Shirakawa, Y.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 263 (01): : 58 - 62
  • [39] Development and Performance of a Gamma-Ray Imaging Detector
    Galvez, J. L.
    Hernanz, M.
    Alvarez, J. M.
    La Torre, M.
    Alvarez, L.
    Karelin, D.
    Lozano, M.
    Pellegrini, G.
    Ullan, M.
    Cabruja, E.
    Martinez, R.
    Chmeissani, M.
    Puigdengoles, C.
    SPACE TELESCOPES AND INSTRUMENTATION 2012: ULTRAVIOLET TO GAMMA RAY, 2012, 8443
  • [40] Development of an MeV gamma-ray imaging detector
    Takeda, A
    Kubo, H
    Miuchi, K
    Nagayoshi, T
    Okada, Y
    Orito, R
    Takada, A
    Tanimori, T
    Ueno, M
    Bouianov, O
    Bouianov, A
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 272 - 276