Highly sensitive electrochemical sensor for tyrosine detection using a sub-millimeter electrode

被引:37
|
作者
Deng, Peihong [1 ]
Xiao, Jingyun [2 ]
Feng, Jinxia [2 ]
Tian, Yaling [2 ]
Wu, Yiyong [2 ]
Li, Junhua [1 ]
He, Quanguo [2 ]
机构
[1] Hengyang Normal Univ, Key Lab Funct Organometall Mat Hunan Prov Univ, Dept Chem & Mat Sci, Key Lab Funct Met Organ Cpds Hunan Prov, Hengyang 421008, Peoples R China
[2] Hunan Univ Technol, Sch Life Sci & Chem, Zhuzhou 412007, Peoples R China
基金
中国国家自然科学基金;
关键词
Acetylene black; Submillimeter electrode; Electrochemical oxidation; Tyrosine sensor; Reduced graphene oxide; BLACK PASTE ELECTRODE; SELECTIVE DETERMINATION; ACETYLENE BLACK; GRAPHENE OXIDE; VOLTAMMETRIC DETERMINATION; MASS-SPECTROMETRY; CARBON NANOTUBES; ASCORBIC-ACID; L-TRYPTOPHAN; FILM;
D O I
10.1016/j.microc.2021.106106
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In recent years, small-sized electrodes have drawn widespread attraction in electroanalysis due to high sensitivity, rapid response and low cost. Hereby, a sub-millimeter paste electrode with inner diameter of 0.8 mm was prepared by combining the excellent properties of reduced graphene oxide (rGO) and acetylene black (AB), and the electrochemical behavior of tyrosine (Tyr) on the modified electrode (denoted as rGO/ABPE) was investigated in detail. The electrochemical responses obtained on the sub-millimeter rGO/ABPE were compared with that obtained on a conventional size electrode with diameter of 3 mm. The results showed that the 0.8 mm one has better performance than that of 3 mm. Compared with the paste electrode made of graphite powder, the oxidation peak current of Tyr increased significantly due to the synergistic effect of rGO and AB. Under the optimized experimental conditions, the calibration curve of Tyr showed a linear relationship between 0.1 and 100 ?M (R = 0.9995) with good sensitivity of 3.314 ?A ?M-1 cm-2, and the detection limit was 0.06 ?M. By comparison with conventional size electrode, the detection of Tyr on the sub-millimeter electrode shows higher sensitivity, wider linear range and lower detection limit. In addition, the excellent reproducibility, stability and selectivity of the sub-millimeter rGO/ABPE make it suitable for Tyr analysis in both food and biological samples.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Performance of a highly-multiplexed sub-millimeter resolution PET detector using silicon-photomultipliers
    Song, TaeYong
    Wu, Heyu
    Komarov, Sergey
    Siegel, Stefan
    Tai, Yuan-Chuan
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [32] Highly Sensitive Electrochemical Detection of Azithromycin with Graphene-Modified Electrode
    Pogacean, Florina
    Varodi, Codruta
    Magerusan, Lidia
    Stefan-van Staden, Raluca-Ioana
    Pruneanu, Stela
    SENSORS, 2022, 22 (16)
  • [33] A highly sensitive electrochemical sensor for bisphenol A using cetyltrimethylammonium bromide functionalized carbon nanohorn modified electrode
    Jing Zhang
    Xiaojian Xu
    Zhidong Chen
    Ionics, 2018, 24 : 2123 - 2134
  • [34] Highly Sensitive Electrochemical Endotoxin Sensor Based on Redox Cycling Using an Interdigitated Array Electrode Device
    Ito, Kentaro
    Inoue, Kumi Y.
    Ito-Sasaki, Takahiro
    Ikegawa, Miho
    Takano, Shinichiro
    Ino, Kosuke
    Shiku, Hitoshi
    MICROMACHINES, 2023, 14 (02)
  • [35] Highly sensitive electrochemical sensor for paeonol using NMP-exfoliated grapheme-modified electrode
    Sun, Dong
    Wang, Sicen
    IONICS, 2015, 21 (10) : 2905 - 2910
  • [36] Integrated microwave sensor for cavity-length measurement with sub-millimeter accuracy
    Megej, A
    Beilenhoff, K
    Schüssler, M
    Ziroff, A
    Mottet, B
    Yilmazoglu, O
    Mutamba, K
    Hamann, CD
    Baican, R
    Hartnagel, HL
    2002 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM DIGEST, VOLS 1-3, 2002, : 643 - 646
  • [37] A highly sensitive electrochemical sensor for bisphenol A using cetyltrimethylammonium bromide functionalized carbon nanohorn modified electrode
    Zhang, Jing
    Xu, Xiaojian
    Chen, Zhidong
    IONICS, 2018, 24 (07) : 2123 - 2134
  • [38] Highly sensitive electrochemical sensor for paeonol using NMP-exfoliated grapheme-modified electrode
    Dong Sun
    Sicen Wang
    Ionics, 2015, 21 : 2905 - 2910
  • [39] Zinc Oxide Nanoparticle-modified Glassy Carbon Electrode as a Highly Sensitive Electrochemical Sensor for the Detection of Caffeine
    Jagadish, Ramu
    Yellappa, Shivaraj
    Mahanthappa, Mallappa
    Chandrasekhar, Kothapalli Bannoth
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2017, 64 (07) : 813 - 821
  • [40] Electrode modified with porous alumina microfibers as a highly sensitive electrochemical sensor for quercetin
    Li, Yaohua
    Huang, Wensheng
    ANALYTICAL METHODS, 2015, 7 (06) : 2537 - 2541