Strength and Structural Performance of Reinforced Concrete Beam with Artificial Plastic Fibre (APF)

被引:1
|
作者
Mokhatar, S. N. [1 ]
Mutalib, N. A. N. A. [2 ]
Budiea, A. M. A. [1 ]
Kamarudin, A. F. [1 ]
Noh, M. S. Md [1 ]
机构
[1] Univ Tun Hussein Onn Malaysia, Fac Civil & Environm Engn, Jamilus Res Ctr, Batu Pahat 86400, Johor, Malaysia
[2] Univ Tun Hussein Onn Malaysia, Grad Ctr, Batu Pahat 86400, Johor, Malaysia
关键词
D O I
10.1088/1757-899X/713/1/012028
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Behaviour of Reinforced Concrete (RC) in beam structure has captured attention of many researchers. Many past researchers investigated the issue of concrete strength in tensile zone. The present research investigates the effect of waste nylon cable ties fibre that act as an Artificial Plastic Fibres (APF) in normal concrete mix and RC beam element. The concrete strength of 30 MPa have been utilized in this research. The percentage of APF that has been mixed with the concrete paste are 1% and 3%. For strength performance, nine (9) cube specimens and nine (9) cylinder specimens were tested under compressive and splitting tensile test, respectively. In addition, six (6) RC beam specimens were prepared and tested under three points bending test in order to investigate its structural performance. Based on the results, 0%, 1% and 3% of APF in concrete mix produces tensile strength of 1.89 MPa, 3.37 MPa and 2.66 MPa respectively. While, from the compression tests, 50.9 MPa, 47.2 MPa and 24.5 MPa were generated from 0%, 1% and 3% of APF, respectively. From this observations, only 1% of APF was employed in concrete mix to produce RC beam for structural performance investigations. Based on three point bending test, RC beam that consisting 1% of APF produced maximum load about 35.98 kN with 1.8 mm deflection compared with control specimen that can only endured until 27.93 kN of maximum load with 2.37 mm deflection. Further observation reveals that cracking of RC beam consisting 1% of APF reduce and delay the crack formation. Overall, utilization of 1% APF in RC beam successfully improves its strength and structural performance.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Impact of Drying on Structural Performance of Reinforced Concrete Beam with Slab
    Satya, Pranjal
    Asai, Tatsuya
    Teshigawara, Masaomi
    Hibino, Yo
    Maruyama, Ippei
    MATERIALS, 2021, 14 (08)
  • [22] Study on deterioration of structural performance of corroded reinforced concrete beam
    Zhong, TY
    Wang, XH
    An, MZ
    PROGRESS IN SAFETY SCIENCE AND TECHNOLOGY, VOL V, PTS A AND B, 2005, 5 : 1963 - 1967
  • [23] Structural Performance of a Reinforced Concrete Double-Beam System
    Lee, Jae-Man
    Lee, Yong-Jun
    Kim, Sang-Woo
    Kim, Kwang-Man
    Lee, Jung-Yoon
    Kim, Kil-Hee
    STRUCTURAL ENGINEERING INTERNATIONAL, 2016, 26 (02) : 130 - 138
  • [24] High performance fibre reinforced concrete
    Mindess, S
    Boyd, AJ
    ADVANCES IN BUILDING TECHNOLOGY, VOLS I AND II, PROCEEDINGS, 2002, : 873 - 880
  • [25] Strength properties of hybrid fibre reinforced quaternary blended high performance concrete
    Poongodi, K.
    Khan, Almas
    Mushraf, Md
    Prathap, V
    Harish, G.
    MATERIALS TODAY-PROCEEDINGS, 2021, 39 : 627 - 632
  • [26] Structural performance of reinforced concrete beams containing plastic waste caps
    Khatib, J.
    Jahami, A.
    Elkordi, A.
    Baalbaki, O.
    MAGAZINE OF CIVIL ENGINEERING, 2019, 91 (07): : 73 - 79
  • [27] Strength and stiffness of fibre-reinforced plastic plates
    Moy, SSJ
    Shenoi, RA
    Allen, HG
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 1996, 116 (02) : 204 - 220
  • [28] Assessment of fibre orientation in ultra high performance fibre reinforced concrete and its effect on flexural strength
    Stephanie J. Barnett
    Jean-Francois Lataste
    Tony Parry
    Steve G. Millard
    Marios N. Soutsos
    Materials and Structures, 2010, 43 : 1009 - 1023
  • [29] Effects of Nylon Fibre and Concrete Strength on the Shrinkage and Fracture Behaviour of Fibre Reinforced Concrete
    Ozsar, Dogac S.
    Ozalp, Fatih
    Yilmaz, H. Dilsad
    Akcay, Burcu
    STRAIN-HARDENING CEMENT-BASED COMPOSITES, 2018, 15 : 188 - 194
  • [30] Performance evaluation of high strength concrete and steel fibre high strength concrete columns reinforced with GFRP bars and helices
    Hasan, Hayder Alaa
    Sheikh, M. Neaz
    Hadi, Muhammad N. S.
    CONSTRUCTION AND BUILDING MATERIALS, 2017, 134 : 297 - 310