Dual-isotope (In-111/Tc-99m) SPECT noise and artifact reduction with an analytic attenuation correction method

被引:2
|
作者
Penney, BC [1 ]
Kao, CM [1 ]
Pan, XC [1 ]
Bidani, N [1 ]
机构
[1] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
关键词
attenuation correction; In-111; noise; single photon emission computed tomography (SPECT); Tc-99m;
D O I
10.1109/TNS.2002.1039556
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Noise and artifacts may reduce lesion delectability in dual-isotope (Tc-99m/In-111) single photon emission computed tomography (SPECT) studies. The effects of attenuation can lead to artifacts near high-activity structures, e.g., the liver, spleen, kidneys, or urinary bladder. Without effective attenuation correction, these artifacts may reduce diagnostic utility. This study compares three processing, methods: 1) zeroth-order Chang's attenuation correction (ZOCAC) with three-dimensional (3-D) Butterworth filtering; 2) quasi-optimal attenuation correction (QOAC) with 3-D Butterworth filtering; and 3) QOAC with a new adaptive filter. A physical phantom is used to determine effective attenuation coefficients to use with Tc-99m and with In-111. Computer simulation studies are used to optimize the parameters of the filters and to compare the three processing methods using bias versus variance plots. The results indicate that QOAC and the adaptive filter both improve the bias-variance tradeoff. Differences between the ZOCAC and the QOAC reconstructions are seen in clinical studies. QOAC noticeably reduces artifacts which have artificially low activity concentration near high-activity structures, e.g-, near the urinary bladder and great vessels in Tc-99m labeled red blood cell images. QOAC, combined with the new adaptive filter, holds promise for improving Tc-99m/In-111 SPECT reconstructions.
引用
收藏
页码:733 / 739
页数:7
相关论文
共 50 条
  • [41] EXPERIMENTAL-VERIFICATION OF ENERGY WEIGHTED DUAL-ISOTOPE TECHNIQUE FOR SIMULTANEOUS TI-201/TC-99M SPECT CARDIAC IMAGING
    HASSELQUIST, BE
    BOUDREAU, RJ
    KUNI, CC
    DUCRET, RP
    DEVITO, R
    JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (05) : P29 - P29
  • [42] Dual-tracer subtraction parathyroid SPECT using Tc-99m pertechnetate and Tc-99m MIBI
    Ekjeen, T.
    Chaichana, A.
    18TH ASIA-OCEANIA CONGRESS OF MEDICAL PHYSICS (AOCMP) & 16TH SOUTH-EAST ASIA CONGRESS OF MEDICAL PHYSICS (SEACOMP), 2019, 1248
  • [43] INFECTED KNEE PROSTHESIS - DIAGNOSIS WITH IN-111 LEUKOCYTE, TC-99M SULFUR COLLOID, AND TC-99M MDP-IMAGING
    PALESTRO, CJ
    SWYER, AJ
    KIM, CK
    GOLDSMITH, SJ
    RADIOLOGY, 1991, 179 (03) : 645 - 648
  • [44] THE COUNT LOSS ARTIFACT IN TC-99M HMPAO LEUKOCYTE SPECT OF THE ABDOMEN
    ZHANG, JJ
    KIM, SM
    PARK, CH
    INTENZO, CM
    CLINICAL NUCLEAR MEDICINE, 1994, 19 (05) : 430 - 434
  • [45] A NEW METHOD OF SIMULTANEOUS DUAL ISOTOPE TC-99M/TL-201 IMAGING AND SPILLDOWN CORRECTION
    WEINSTEIN, H
    HADEMENOS, G
    REINHARDT, CP
    MCSHERRY, B
    WIRONEN, J
    LEPPO, JA
    CIRCULATION, 1992, 86 (04) : 707 - 707
  • [46] Enhanced cross-talk correction technique for simultaneous dual-isotope imaging: A Tl-201/Tc-99m myocardial perfusion SPECT dog study.
    Knesaurek, K
    Machac, J
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 978 - 978
  • [47] Tc-99m HMPAO-SPECT With CT Attenuation Correction Improves Detection of Epileptogenic Areas
    Farid, Karim
    Sibon, Igor
    Fernandez, Philippe
    Michel, Veronique
    Barret, Olivier
    Allard, Michele
    CLINICAL NUCLEAR MEDICINE, 2009, 34 (05) : 290 - 291
  • [48] A method to correct myocardial SPECT with Tc-99m compounds for scatter and attenuation without transmission
    Kupferschlager, J
    Muller, B
    Schulz, G
    Kaiser, HJ
    Wagenknecht, G
    Bares, R
    Bull, U
    NUKLEARMEDIZIN, 1997, 36 (02) : 56 - 64
  • [49] Attenuation and scatter correction in brain SPECT with Tc-99m labeled receptor-specific radiopharmaceuticals
    Jang, S
    Mozley, PD
    Barraclough, ED
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 1569 - 1573
  • [50] Clinical value of attenuation correction in stress-only Tc-99m sestamibi SPECT imaging
    Heller, GV
    Bateman, TM
    Johnson, LL
    Cullom, SJ
    Case, JA
    Galt, JR
    Garcia, EV
    Haddock, K
    Moutray, KL
    Poston, C
    Botvinick, EH
    Fish, MB
    Follansbee, WP
    Hayes, S
    Iskandrian, AE
    Mahmarian, JJ
    Vandecker, W
    JOURNAL OF NUCLEAR CARDIOLOGY, 2004, 11 (03) : 273 - 281