Dual-isotope (In-111/Tc-99m) SPECT noise and artifact reduction with an analytic attenuation correction method

被引:2
|
作者
Penney, BC [1 ]
Kao, CM [1 ]
Pan, XC [1 ]
Bidani, N [1 ]
机构
[1] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
关键词
attenuation correction; In-111; noise; single photon emission computed tomography (SPECT); Tc-99m;
D O I
10.1109/TNS.2002.1039556
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Noise and artifacts may reduce lesion delectability in dual-isotope (Tc-99m/In-111) single photon emission computed tomography (SPECT) studies. The effects of attenuation can lead to artifacts near high-activity structures, e.g., the liver, spleen, kidneys, or urinary bladder. Without effective attenuation correction, these artifacts may reduce diagnostic utility. This study compares three processing, methods: 1) zeroth-order Chang's attenuation correction (ZOCAC) with three-dimensional (3-D) Butterworth filtering; 2) quasi-optimal attenuation correction (QOAC) with 3-D Butterworth filtering; and 3) QOAC with a new adaptive filter. A physical phantom is used to determine effective attenuation coefficients to use with Tc-99m and with In-111. Computer simulation studies are used to optimize the parameters of the filters and to compare the three processing methods using bias versus variance plots. The results indicate that QOAC and the adaptive filter both improve the bias-variance tradeoff. Differences between the ZOCAC and the QOAC reconstructions are seen in clinical studies. QOAC noticeably reduces artifacts which have artificially low activity concentration near high-activity structures, e.g-, near the urinary bladder and great vessels in Tc-99m labeled red blood cell images. QOAC, combined with the new adaptive filter, holds promise for improving Tc-99m/In-111 SPECT reconstructions.
引用
收藏
页码:733 / 739
页数:7
相关论文
共 50 条
  • [1] A modified TEW approach to scatter correction for In-111 and Tc-99m dual-isotope small-animal SPECT
    Prior, Paul
    Timmins, Rachel
    Petryk, Julia
    Strydhorst, Jared
    Duan, Yin
    Wei, Lihui
    Wells, R. Glenn
    MEDICAL PHYSICS, 2016, 43 (10) : 5503 - 5513
  • [2] Detection of cerebrospinal fluid leak by dual-isotope SPECT with In-111 DTPA and Tc-99m HMDP
    Okizaki, A
    Shuke, N
    Aburano, T
    Hashizume, K
    Nakai, H
    Tanaka, T
    CLINICAL NUCLEAR MEDICINE, 2001, 26 (07) : 628 - 629
  • [3] The Effect of Model-based Scatter Correction for Simultaneous Dual-isotope Tc-99m/In-111 Neuroendocrine SPECT/CT studies
    Shcherbinin, S.
    Celler, A.
    Chamoiseau, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S439 - S439
  • [4] Attenuation correction in dual-isotope TL-201 (rest) and Tc-99m Sestamibi (stress) myocardial spect
    Storto, G
    Prior, JO
    Besseghir, N
    Delaloye, AB
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (08): : 1002 - 1002
  • [5] Cross-talk correction for dual isotope In-111/Tc-99m small animal cardiac SPECT imaging
    Timmins, Rachel
    Wells, R. Glenn
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [6] Accurate spill-down and scatter correction for Tc-99m/In-111 SPECT
    Feng, J
    Penney, BC
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1562 - 1566
  • [7] Dual radiotracer SPECT/CT for osteomyelitis: Patterns of Tc-99m MDP and In-111 WBC uptake
    Barker, David
    Hall, Nathan
    Natwa, Mona
    Knopp, Michael
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [8] A NEW DUAL-ISOTOPE CONVOLUTION CROSS-TALK CORRECTION METHOD - A TL-201 TC-99M SPECT CARDIAC PHANTOM STUDY
    KNESAUREK, K
    MEDICAL PHYSICS, 1994, 21 (10) : 1577 - 1583
  • [9] Simultaneous I-123/Tc-99m dual-isotope myocardial SPECT imaging with crosstalk compensation
    Du, Yong
    DiPaula, Anthony
    Frank, Terry
    Higuchi, Takahiro
    Becker, Lewis
    Links, Jonathan
    Lardo, Albert
    Bengel, Frank
    Frey, Eric
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [10] MEASURED DEFECT CONTRAST WITH SIMULTANEOUS TL-201/TC-99M DUAL-ISOTOPE CARDIAC SPECT
    GILLAND, DR
    JASZCZAK, RJ
    GREER, KL
    COLEMAN, RE
    JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (05) : P196 - P196