Fibrinogen-coated bismuth film electrodes for voltammetric analysis of lead and cadmium using the batch injection analysis

被引:21
|
作者
Adraoui, I.
Rhazi, M. E.
Amine, A.
机构
关键词
batch injection analysis; fibrinogen; bismuth film; surfactants; heavy metals; stripping;
D O I
10.1080/00032710600964676
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work reports the application of fibrinogen-coated bismuth films deposited on carbon paste electrodes (Fbg-BiFEs) for the simultaneous determination of trace amounts of lead and cadmium by square-wave anodic stripping voltammetry, combined with a batch injection analysis technique (BIA-SWASV). The batch injection analysis system provides the advantages of rapid and simple electroanalysis of microliter samples. Its use in combination with Fbg-BiFEs allowed the determination of metals at trace levels in environmental samples, given that the surfactant interference observed with stripping analysis at bismuth electrodes could be minimized by use of a fibrinogen coating. The analytical characteristics, namely sensitivity, detection limits, and resistance to surfactants in the anodic stripping voltammetry of lead and cadmium, were investigated in acetate buffer. The resulting limits of detection were 0.2 mu g L-1 and 0.1 mu g L-1, for Cd and Pb respectively. Finally, the system based on Fbg-BiFEs combined with BIA-SWASV was applied to different real samples ( tap water and tea samples) for analysis of trace metals with satisfactory results.
引用
收藏
页码:349 / 367
页数:19
相关论文
共 50 条
  • [1] Determination of lead, cadmium, zinc using bismuth-film electrodes by potentiometric stripping analysis
    Li, JP
    Peng, TH
    Zhang, XJ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 30 (09) : 1092 - 1095
  • [2] Sequential injection monosegmented flow voltammetric determination of cadmium and lead using a bismuth film working electrode
    Siriangkhawut, Watsaka
    Pencharee, Somkid
    Grudpan, Kate
    Jakmunee, Jaroon
    TALANTA, 2009, 79 (04) : 1118 - 1124
  • [3] COMPARATIVE-STUDY OF POLYMER-COATED MERCURY FILM ELECTRODES FOR VOLTAMMETRIC ANALYSIS OF LEAD AND CADMIUM IN THE PRESENCE OF SURFACTANTS
    DAM, MER
    THOMSEN, KN
    PICKUP, PG
    SCHRODER, KH
    ELECTROANALYSIS, 1995, 7 (01) : 70 - 78
  • [4] Stripping Voltammetry of Trace Metals at Bismuth-Film Electrodes by Batch-Injection Analysis
    Economou, Anastasios
    Voulgaropoulos, Anastasios
    ELECTROANALYSIS, 2010, 22 (13) : 1468 - 1475
  • [5] Polypyrrole coated mercury film electrodes for sono-ASV analysis of cadmium and lead
    Tsai, YC
    Davis, J
    Compton, RG
    Ito, S
    Ono, N
    ELECTROANALYSIS, 2001, 13 (01) : 7 - 12
  • [7] Simultaneous flow injection analysis of cadmium and lead with differential pulse voltammetric detection
    Alpizar, J
    Cladera, A
    Cerda, V
    Lastres, E
    Garcia, L
    Catasus, M
    ANALYTICA CHIMICA ACTA, 1997, 340 (1-3) : 149 - 158
  • [8] Nafion-coated mercury thin film electrodes for batch-injection analysis with anodic stripping voltammetry
    Brett, CMA
    Brett, AMO
    Matysik, FM
    Matysik, S
    Kumbhat, S
    TALANTA, 1996, 43 (11) : 2015 - 2022
  • [9] Nafion-coated bismuth film electrodes for the determination of trace lead and cadmium in herbal medicines by anodic stripping voltammetry
    Xu He
    Zeng Li-Ping
    Xing Su-Jie
    Xian Yue-Zhong
    Jin Li-Tong
    CHINESE JOURNAL OF CHEMISTRY, 2008, 26 (05) : 847 - 853
  • [10] Voltammetric Determination of Lead (II) and Cadmium (II) Using a Bismuth Film Electrode Modified with Mesoporous Silica Nanoparticles
    Yang, Die
    Wang, Liang
    Chen, Zuliang
    Megharaj, Mallavarapu
    Naidu, Ravi
    ELECTROCHIMICA ACTA, 2014, 132 : 223 - 229