Direct isotope analysis of Chernobyl microparticles using time-of-flight mass spectrometry with pulsed glow discharge

被引:16
|
作者
Ganeev, Aleksander [1 ,2 ]
Gubal, Anna [1 ]
Korotetski, Boris [1 ,2 ]
Bogdanova, Oksana [3 ]
Burakov, Boris [3 ]
Titova, Anna [1 ]
Solovyev, Nikolay [1 ]
Ivanenko, Natalya [1 ,4 ]
Drobyshev, Evgenii [4 ]
Iakovleva, Evgenia [5 ,6 ]
Sillanpaa, Mika [5 ,6 ]
机构
[1] St Petersburg State Univ, Univ Skaya Nab 7-9, St Petersburg 199034, Russia
[2] ITMO Univ, Kronverkskiy Pr 49, St Petersburg 197101, Russia
[3] VG Khlopin Radium Inst, 2nd Murinskiy Pr 28, St Petersburg 194021, Russia
[4] Fed Medicobiol Agcy, Inst Toxicol, Ul Belchtereva 1, St Petersburg 192019, Russia
[5] Lappeenranta Univ Technol, Sch Engn Sci, Lab Green Chem, Sammonkatu 12, FI-50130 Mikkeli, Finland
[6] Florida Int Univ, Dept Civil & Environm Engn, 10555 West Flogger St, Miami, FL 33174 USA
关键词
Uranium; Isotope analysis; Glow discharge mass spectrometry; Microparticle; Combined hollow cathode; Chernobyl accident; INDIVIDUAL PARTICLES; ALPHA-SPECTROMETRY; RATIO ANALYSIS; URANIUM; PLUTONIUM; NUCLEAR; SIMS;
D O I
10.1016/j.microc.2017.02.015
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
After the Chernobyl nuclear accident in 1986, numerous specimens of the so-called 'fuel-containing masses' or the Chernobyl 'lava' and hot particles were collected. Isotope analysis of Chernobyl specimens is the subject of special interest, since unexpected results on U-238/U-235 ratio has been reported previously. Although, over 30 years have passed since the Chernobyl accident, these samples are still a source of important information about the catastrophe as well as about the environmental behavior of highly radioactive materials. In the current study, glow discharge mass spectrometry with combined hollow cathode, pulse power supply and time-of-flight mass spectrometer was employed for the isotope analysis of uranium in Chernobyl-born microparticles. Six Chernobyl specimens (three crystals of artificial high-uranium zircon from the Chernobyl 'lava' and two hot particles) were analyzed. The method was optimized to cope the adverse oxide interferences. Simple isotope calibration with a single reference material of UO2 with known U-235 content (abundance, 1.80 +/- 0.03%) was used. The validity of the method was checked using the sample with natural U-235 abundance (0.72%) and by comparing with sector field inductively coupled plasma mass spectrometry. The relative error of 235U determination was ca. 1%, which is comparable to or excels the values, obtained by the competitive approaches (e.g. laser ablation inductively coupled plasma mass spectrometry, accelerator mass spectrometry or resonance ionization mass spectrometry). An important advantage of the developed method is the possibility to conduct direct analysis with partial preservation of varied solid materials without preliminary dissolution, separation or concentrating procedures. Other than partial sample preservation, this provides lower hazards to the analyst, owing to shorter sample handling time and lower probability of radioisotopes volatilization or their turning to aerosols. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:286 / 292
页数:7
相关论文
共 50 条
  • [31] Absolute methods of quantitation in glow discharge mass spectrometry with a time-of-flight mass analyzer
    McClenathan, Denise M.
    Hieftje, Gary M.
    Journal of Analytical Atomic Spectrometry, 2005, 20 (12): : 1326 - 1331
  • [32] Microsecond pulsed versus direct current glow discharge as ion sources for analytical glow discharge-time of flight mass spectrometry
    Martín, Antonio
    Pereiro, Rosario
    Bordel, Nerea
    Sanz-Medel, Alfredo
    Journal of Analytical Atomic Spectrometry, 2007, 22 (09): : 1179 - 1183
  • [33] Elemental ratio determinations and compound-independent calibration using microsecond pulsed glow discharge time-of-flight mass spectrometry
    Sola-Vazquez, Auristela
    Costa-Fernandez, Jose M.
    Pereiro, Rosario
    Sanz-Medel, Alfredo
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 401 (09) : 2771 - 2777
  • [34] Elemental ratio determinations and compound-independent calibration using microsecond pulsed glow discharge time-of-flight mass spectrometry
    Auristela Solà-Vázquez
    José M. Costa-Fernández
    Rosario Pereiro
    Alfredo Sanz-Medel
    Analytical and Bioanalytical Chemistry, 2011, 401 : 2771 - 2777
  • [35] A comparison of non-pulsed radiofrequency and pulsed radiofrequency glow discharge orthogonal time-of-flight mass spectrometry for analytical purposes
    Lobo, L.
    Pisonero, J.
    Bordel, N.
    Pereiro, R.
    Tempez, A.
    Chapon, P.
    Michler, J.
    Hohl, M.
    Sanz-Medel, A.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2009, 24 (10) : 1373 - 1381
  • [36] Lumas-30 time-of-flight mass spectrometer with pulsed glow discharge for direct determination of nitrogen in steel
    A. A. Ganeev
    A. R. Gubal’
    V. I. Mosichev
    N. V. Pershin
    S. N. Petrov
    S. V. Potapov
    K. N. Uskov
    Journal of Analytical Chemistry, 2011, 66 : 1411 - 1416
  • [37] Lumas-30 time-of-flight mass spectrometer with pulsed glow discharge for direct determination of nitrogen in steel
    Ganeev, A. A.
    Gubal', A. R.
    Mosichev, V. I.
    Pershin, N. V.
    Petrov, S. N.
    Potapov, S. V.
    Uskov, K. N.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 66 (14) : 1411 - 1416
  • [38] Direct Sample Analysis/Time-of-Flight Mass Spectrometry
    Tyler, Andrew
    Dalmia, Avinash
    AMERICAN LABORATORY, 2014, 46 (01) : 38 - 40
  • [39] Quantitative depth profile analysis by direct current glow discharge time of flight mass spectrometry
    Sanz-Medel, A. (asm@correo.uniovi.es), 1600, Royal Society of Chemistry (18):
  • [40] Quantitative depth profile analysis by direct current glow discharge time of flight mass spectrometry
    Peláez, MV
    Costa-Fernández, JM
    Pereiro, R
    Bordel, N
    Sanz-Medel, A
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (08) : 864 - 871