Variability in the measurement of minimum fibrous cap thickness and reproducibility of fibroatheroma classification by optical coherence tomography using manual versus semiautomatic assessment
被引:23
|作者:
Radu, Maria D.
[1
]
Yamaji, Kyohei
[2
]
Garcia-Garcia, Hector M.
[3
]
Zaugg, Serge
[4
]
Taniwaki, Masanori
[2
]
Koskinas, Konstantinos C.
[2
]
Serruys, Patrick W.
[5
]
Windecker, Stephan
[2
]
Dijkstra, Jouke
[6
]
Raber, Lorenz
[2
]
机构:
[1] Copenhagen Univ Hosp, Rigshosp, Copenhagen, Denmark
[2] Bern Univ Hosp, Dept Cardiol, CH-2010 Bern, Switzerland
[3] Washington Hosp Ctr, Intervent Cardiol, Washington, DC 20010 USA
[4] Bern Univ, Clin Trials Unit, Bern, Switzerland
[5] Imperial Coll London, Natl Heart & Lung Inst, Int Ctr Circulatory Hlth, London, England
[6] Leiden Univ, Med Ctr, Leiden, Netherlands
关键词:
atherosclerosis;
computer-assisted image analysis;
coronary artery disease;
optical coherence tomography;
thin-cap fibroatheroma;
ACUTE MYOCARDIAL-INFARCTION;
NATIVE CORONARY-ARTERIES;
PLAQUE;
QUANTIFICATION;
IMPLANTATION;
MORPHOLOGY;
DISEASE;
D O I:
10.4244/EIJV12I8A162
中图分类号:
R5 [内科学];
学科分类号:
1002 ;
100201 ;
摘要:
AIMS:The minimum fibrous cap thickness (FCT) is considered a major criterion of coronary plaque vulnerability according to autopsy studies. We aimed to assess the reproducibility in the measurement of the optical coherence tomography (OCT)-detected minimum FCT and the agreement in the classification of thin-cap fibroatheroma (TCFA), by a software-based semi-automatic method compared with the manual method. METHODS AND RESULTS:A total of 50 frames with fibroatheromas (FA) were randomly selected from the Integrated Biomarker Imaging Study-4 (IBIS-4). Two experienced OCT analysts independently measured the minimum FCT at two different time points, manually and by three different semi-automatic software-based algorithms, based on the assessment of light intensity along the axial scan line. A TCFA was defined as an FA with minimum FCT <65 mu m. The inter- and intra-observer reproducibility of the manual measurement of the minimum FCT was moderate with an intra-class correlation coefficient (ICC) of 0.71 and 0.79, respectively. The corresponding ICCs by either one of the three semi-automatic algorithms were 0.99. When categorising FA according to the minimum FCT based on the manual assessment, the inter- and intra-observer agreement was poor (kappa=0.23) and moderate (kappa=0.50), respectively. In contrast, the semi-automatic assessment showed perfect agreement for both inter- and intra-observer assessments (kappa=0.90-1.00 and 1.00, respectively). CONCLUSIONS:While semi-automatic assessment of FCT and TCFA classification was associated with excellent reproducibility and agreement, manual measurements were associated with a moderate reproducibility and agreement in the quantification of FCT and classification of TCFA.