Quality evaluation of golden saxifrage (Chrysosplenium alternifolium L.) through simultaneous determination of four bioactive flavonoids by high-performance liquid chromatography with PDA detection

被引:7
|
作者
Olszewska, Monika Anna [1 ]
Gudej, Jan [1 ]
机构
[1] Med Univ Lodz, Fac Pharm, Dept Pharmacognosy, PL-90151 Lodz, Poland
关键词
RP-HPLC; PDA; Chrysosplenium alternifolium L; Flavonoids; Chrysosplenols B and D; Chrysosplenosides B and D; POLYMETHOXYLATED FLAVONES; SEPARATION; QUERCETIN; AGLYCONES;
D O I
10.1016/j.jpba.2009.06.020
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
To control the quality of Chrysosplenium alternifolium L., a simple, fast and reliable method of high-performance liquid chromatography coupled with a photodiode array detector (HPLC-PDA) was developed and validated for simultaneous quantitative determination of four bioactive polymethoxylated flavonoids, namely chrysosplenosides B and D, and chrysosplenols B and D. Separation of the four analytes was accomplished on a C18 Hypersil ODS column (5 mu m, 125 mm x 4 mm, i.d.) with an acetonitrile 10-100% (v/v) elution gradient, recorded at 345 nm. The equilibration of the methanol extracts and standard solution to 30% (v/v) of water was found to be necessary when minimizing viscosity differences between injections and the mobile phase, and thereby when minimizing distortions of analyte peaks and maximizing the resolution of critical bands of chrysosplenosides B and D. The correlation coefficients of all the calibration curves showed excellent linearity (r=0.9999) over the wide test range. The relative standard deviation of the method was less than 3.53 and 4.41% for intra- and inter-day assays, and the average recoveries were between 95.3 and 103.5%. High sensitivity was demonstrated with detection limits between 0.012 and 0.029 mu g/ml (0.24-0.58 ng). C. alternifolium was found to be a valuable source of the flavonoids with the total content ranging from 2.456 to 4.314% of dry weight, depending on harvest time and cultivation area. The total flavonoids were also determined using the pharmacopeial UV-spectrophotometric method and a notable underestimation was found in comparison to the developed HPLC method. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:771 / 777
页数:7
相关论文
共 50 条
  • [1] Quality evaluation of Platycladus orientalis (L.) Franco through simultaneous determination of four bioactive flavonoids by high-performance liquid chromatography
    Lu, Yan-hua
    Liu, Zhi-yong
    Wang, Zheng-tao
    Wei, Dong-zhi
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 41 (04) : 1186 - 1190
  • [2] Simultaneous determination of four bioactive compounds in Verbena officinalis L. by using high-performance liquid chromatography
    Liu, Zhen
    Xu, Zhiwei
    Zhou, Hanyu
    Cao, Gang
    Cong, Xiao-Dong
    Zhang, Yun
    Cai, Bao-Chang
    PHARMACOGNOSY MAGAZINE, 2012, 8 (30) : 162 - 165
  • [3] Simultaneous Determination of Bioactive Flavonoids in Some Selected Korean Thistles by High-Performance liquid Chromatography
    Thao, Nguyen Thi Phuong
    Cuong, To Dao
    Hung, Tran Manh
    Lee, Je Hyun
    Na, MinKyun
    Son, Jong Keun
    Jung, Hyun Ju
    Fang, Zhe
    Woo, Mi Hee
    Choi, Jae Sue
    Min, Byung-Sun
    ARCHIVES OF PHARMACAL RESEARCH, 2011, 34 (03) : 455 - 461
  • [4] Simultaneous determination of bioactive flavonoids in some selected Korean thistles by high-performance liquid chromatography
    Nguyen Thi Phuong Thao
    To Dao Cuong
    Tran Manh Hung
    Je Hyun Lee
    MinKyun Na
    Jong Keun Son
    Hyun Ju Jung
    Zhe Fang
    Mi Hee Woo
    Jae Sue Choi
    Byung-Sun Min
    Archives of Pharmacal Research, 2011, 34
  • [5] Simultaneous Determination of Five Bioactive Flavonoids in Pericarpium Citri Reticulatae from China by High-Performance Liquid Chromatography with Dual Wavelength Detection
    Zheng, GuoDong
    Yang, DePo
    Wang, DongMei
    Zhou, Fang
    Yang, Xue
    Jiang, Lin
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2009, 57 (15) : 6552 - 6557
  • [6] Quality determination of Crocus sativus L. flower by high-performance liquid chromatography
    Moratalla-Lopez, Natalia
    Sanchez, Ana M.
    Lorenzo, Candida
    Lopez-Corcoles, Horacio
    Alonso, Gonzalo L.
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2020, 93
  • [7] Determination of four lignans in Phyllanthus niruri L. by a simple high-performance liquid chromatography method with fluorescence detection
    Murugaiyah, Vikneswaran
    Chan, Kit-Lam
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1154 (1-2) : 198 - 204
  • [8] SIMULTANEOUS DETERMINATION OF FOUR FLAVONOID AGLYCONE ANALOGS IN THE INFLORESCENCE OF JUGLANS REGIA L. BY HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY-DIODE ARRAY DETECTION
    Zhao, Lei
    Li, Jintian
    Wang, Tongwen
    Liu, Lina
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2013, 36 (14) : 1986 - 1998
  • [9] Simultaneous Determination of Five Flavonoids in Saussurea mongolica Franch by High-Performance Liquid Chromatography
    Chen, J.
    Shi, Y-P
    ACTA CHROMATOGRAPHICA, 2012, 24 (03) : 489 - 499
  • [10] Simultaneous determination of lysophospholipids by high-performance liquid chromatography with fluorescence detection
    Servillo, L
    Iorio, EL
    Quagliuolo, L
    Camussi, G
    Balestrieri, C
    Giovane, A
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1997, 689 (02): : 281 - 286