Adapting the diagnostic definitions of the RDC/TMD to routine clinical practice: A feasibility study

被引:18
|
作者
Hasanain, Fatin [1 ]
Durham, Justin [1 ]
Moufti, Adel [1 ]
Steen, Ian Nick [1 ]
Wassell, Robert W. [1 ]
机构
[1] Sch Dent Sci, Dept Restorat Dent, Newcastle Upon Tyne NE2 4BW, Tyne & Wear, England
关键词
RDC/TMD; Reliability; CEP-TMD; Physical TMD diagnosis; Clinical tool; TEMPOROMANDIBULAR DISORDERS; RELIABILITY; ADOLESCENTS; CHILDREN; SIGNS; TMD;
D O I
10.1016/j.jdent.2009.08.001
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) is a well-known diagnostic tool for clinical trials on TMD. Objectives: This study aims to assess the reliability, validity and feasibility of a new method of physically diagnosing temporomandibular disorders (TMD), designed for routine clinical use. This version, known as Clinical Examination Protocol-TMD (CEP-TMD), was compared to the gold standard original RDC/TMD. Methods: A total of 49 subjects (41 referred TMD patients and 8 symptom free subjects) were examined using both RDC/TMD and CEP-TMD versions. Three examiners, with varying levels of experience in diagnosing TMD, worked in pairs. Each member of a pair saw the same patient twice, once for the RDC/TMD and once for the CEP-TMD examination. The examination order was randomized. Each patient's examinations alternated between examiners to reduce the memory effect. Examinations could yield single, multiple or no diagnosis. Kappa statistics were calculated to estimate reliability. Results: There was substantial overall agreement between the CEP-TMD and the RDC/TMD (kappa = 0.70). Intra-examination agreements were substantial in both RDC/TMD (kappa = 0.70) and CEP-TMD (kappa = 0.90). For examination and diagnosis, the CEP-TMD was almost 3 min faster than the RDC/TMD (p < 0.05). Conclusions: It was concluded that the CEP-TMD's diagnosis is comparable to the RDC/TMD thus providing a convenient and intuitive approach for dentists to physically diagnose TMD in clinical practice. The well-established RDC/TMD remains the gold standard for research diagnosis of TMD. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:955 / 962
页数:8
相关论文
共 50 条
  • [21] Operator training requirements and diagnostic accuracy of Fibroscan in routine clinical practice
    Armstrong, M. J.
    Corbett, C.
    Hodson, J.
    Marwah, N.
    Parker, R.
    Houlihan, D. D.
    Rowe, I. A.
    Hazlehurst, J. M.
    Brown, R.
    Huebscher, S. G.
    Mutimer, D.
    POSTGRADUATE MEDICAL JOURNAL, 2013, 89 (1058) : 685 - 692
  • [22] Feasibility and Validity of the Pediatric Ulcerative Colitis Activity Index in Routine Clinical Practice
    Dotson, Jennifer L.
    Crandall, Wallace V.
    Zhang, Peixin
    Forrest, Christopher B.
    Bailey, L. Charles
    Colletti, Richard B.
    Kappelman, Michael D.
    JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 2015, 60 (02): : 200 - 204
  • [23] Interferon-β bioactivity measurement in multiple sclerosis: feasibility for routine clinical practice
    van der Voort, L. F.
    Kok, A.
    Visser, A.
    Oudejans, C. B. M.
    Caldano, M.
    Gilli, F.
    Bertolotto, A.
    Polman, C. H.
    Killestein, J.
    MULTIPLE SCLEROSIS, 2009, 15 (02): : 212 - 218
  • [24] Investigating the feasibility of tumour molecular profiling in gastrointestinal malignancies in routine clinical practice
    Moorcraft, S. Y.
    de Castro, D. Gonzalez
    Cunningham, D.
    Jones, T.
    Walker, B. A.
    Peckitt, C.
    Yuan, L. C.
    Frampton, M.
    Begum, R.
    Eltahir, Z.
    Wotherspoon, A.
    Mendes, L. S. Teixeira
    Wilson, S. Hulkki
    Gillbanks, A.
    Baratelli, C.
    Fotiadis, N.
    Patel, A.
    Braconi, C.
    Valeri, N.
    Gerlinger, M.
    Rao, S.
    Watkins, D.
    Chau, I.
    Starling, N.
    ANNALS OF ONCOLOGY, 2018, 29 (01) : 230 - 236
  • [25] Fully Automated Echocardiogram Interpretation in Clinical Practice: Feasibility and Diagnostic Accuracy
    Zhang, Jeffrey
    Gajjala, Sravani
    Agrawal, Pulkit
    Tison, Geoffrey H.
    Hallock, Laura A.
    Beussink-Nelson, Lauren
    Lassen, Mats H.
    Fan, Eugene
    Aras, Mandar A.
    Jordan, ChaRandle
    Fleischmann, Kirsten E.
    Melisko, Michelle
    Qasim, Atif
    Shah, Sanjiv J.
    Bajcsy, Ruzena
    Deo, Rahul C.
    CIRCULATION, 2018, 138 (16) : 1623 - 1635
  • [26] Empowerment and satisfaction in a multinational study of routine clinical practice
    Clarke, E.
    Puschner, B.
    Jordan, H.
    Williams, P.
    Konrad, J.
    Kawohl, W.
    Baer, A.
    Roessler, W.
    Del Vecchio, V.
    Sampogna, G.
    Nagy, M.
    Sueveges, A.
    Bording, M. Krogsgaard
    Slade, M.
    ACTA PSYCHIATRICA SCANDINAVICA, 2015, 131 (05) : 369 - 378
  • [27] Feasibility and clinical decision-making with 3D echocardiography in routine practice
    Hare, J. L.
    Jenkins, C.
    Nakatani, S.
    Ogawa, A.
    Yu, C-M
    Marwick, T. H.
    HEART, 2008, 94 (04) : 440 - 445
  • [28] Feasibility of adjuvant treatment with docetaxel/doxorubicinl cyclophosphamide (the TAC regimen) in routine clinical practice
    Gounaris, I.
    Kelly, S.
    MacLeod, P.
    EJC SUPPLEMENTS, 2008, 6 (07): : 122 - 122
  • [29] Feasibility of Expediting Radiotherapy Clinical Workflow by Planning on Diagnostic Images and Adapting on a Commercial Adaptive Radiotherapy System
    Zhao, T.
    Henke, L. E.
    Kim, H.
    Robinson, C. G.
    Hugo, G. D.
    Mutic, S.
    Cai, B.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : S185 - S186
  • [30] The Feasibility of Implementing a Sexual Risk Reduction Intervention in Routine Clinical Practice at an ARV Clinic in Cape Town: A Case Study
    Sarah Dewing
    Catherine Mathews
    Nikki Schaay
    Allanise Cloete
    Leickness Simbayi
    Mickey Chopra
    AIDS and Behavior, 2011, 15 : 905 - 910