Heat transfer and pressure drop during HFC refrigerant saturated vapour condensation inside a brazed plate heat exchanger

被引:50
|
作者
Longo, Giovanni A. [1 ]
机构
[1] Univ Padua, Dept Management & Engn, I-36100 Vicenza, Italy
关键词
Brazed plate hear exchanger; Condensation; HFC refrigerant; Heat transfer coefficient; Pressure drop; SURFACE CONDENSATION; VAPORIZATION; R-134A;
D O I
10.1016/j.ijheatmasstransfer.2009.11.003
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presents the heat transfer coefficients and the pressure drop measured during HFC refrigerants 236fa. 134a and 410A saturated vapour condensation inside a brazed plate heat exchanger: the effects of saturation temperature (pressure), refrigerant mass flux and fluid properties are investigated. The heat transfer coefficients show weak sensitivity to saturation temperature (pressure) and great sensitivity to refrigerant mass flux and fluid properties. A transition point between gravity controlled and forced convection condensation has been found for a refrigerant mass flux around 20 kg/m(2)s that corresponds to an equivalent Reynolds number around 1600-1700. At low refrigerant mass flux (G(r) < 20 kg/m(2)s) the heat transfer coefficients are not dependent on mass flux and are well predicted by the Nusselt [20] analysis for vertical surface the condensation process is gravity controlled. For higher refrigerant mass flux (G(r) > 20 kg/m(2)s) the heat transfer coefficients depend on mass flux and are well predicted by Akers et al. [21] equation: forced convection condensation occurs. In the forced convection condensation region the heat transfer coefficients show a 25-30% increase for a doubling of the refrigerant mass flux. The frictional pressure drop shows a linear dependence on the kinetic energy per unit volume of the refrigerant flow and therefore a quadratic dependence oil mass flux. HFC-410A shows heat transfer coefficients similar to HFC-134a and 10% higher than HFC-236fa together with frictional pressure drops 40-50% lower than HFC-134a and 50-60% lower than HFC-236fa. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1079 / 1087
页数:9
相关论文
共 50 条
  • [21] Hydrocarbon refrigerants condensation local heat transfer coefficients inside a brazed plate heat exchanger (BPHE)
    Longo, Giovanni A.
    Mancin, Simone
    Righetti, Giulia
    Zilio, Claudio
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2023, 201
  • [22] Evaporation heat transfer and pressure drop of refrigerant R-134a in a plate heat exchanger
    Yan, YY
    Lin, TF
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1999, 121 (01): : 118 - 127
  • [23] Heat transfer and pressure drop during supercritical cooling of HFC refrigerant blends
    Garimella, Srinivas
    Mitra, Biswajit
    Andresen, Ulf C.
    Jiang, Yirong
    Fronk, Brian M.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2015, 91 : 477 - 493
  • [24] HFC-410A vaporisation inside a commercial brazed plate heat exchanger
    Longo, Giovanni A.
    Gasparella, Andrea
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2007, 32 (01) : 107 - 116
  • [25] Condensation of the low GWP refrigerant HFO1234ze(E) inside a Brazed Plate Heat Exchanger
    Longo, Giovanni A.
    Zilio, Claudio
    Righetti, Giulia
    Brown, J. Steven
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2014, 38 : 250 - 259
  • [26] Experimental investigation on heat transfer and pressure drop of brazed plate heat exchanger using LiBr solution
    Ham, Jeonggyun
    Yong, Junhyeok
    Kwon, Ohkyung
    Bae, Kyungjin
    Cho, Honghyun
    APPLIED THERMAL ENGINEERING, 2023, 225
  • [27] A new computational procedure for heat transfer and pressure drop during refrigerant condensation inside enhanced tubes
    Cavallini, A
    Del Col, D
    Doretti, L
    Longo, GA
    Rossetto, L
    JOURNAL OF ENHANCED HEAT TRANSFER, 1999, 6 (06) : 441 - 456
  • [28] Heat transfer and pressure drop analysis on evaporation of refrigerant R410a in plate heat exchanger
    Qiu, Feng
    Zeng, Wei-Ping
    Gu, Bo
    Shanghai Jiaotong Daxue Xuebao/Journal of Shanghai Jiaotong University, 2009, 43 (10): : 1612 - 1615
  • [29] Plate heat exchanger literature survey and new heat transfer and pressure drop correlations for refrigerant evaporators
    Ayub, ZH
    HEAT TRANSFER ENGINEERING, 2003, 24 (05) : 3 - 16
  • [30] Experimental investigation of condensation pressure drop of zeotropic refrigerant/oil mixtures in plate heat exchanger
    Wang, Zhiqi
    Xu, Zehua
    Luo, Lan
    Xia, Xiaoxia
    Peng, Deqi
    Li, Xin
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 149 : 192 - 203