Contactless Video-Based Heart Rate Monitoring of a Resting and an Anesthetized Pig

被引:11
|
作者
Wang, Meiqing [1 ]
Youssef, Ali [1 ]
Larsen, Mona [1 ]
Rault, Jean-Loup [2 ]
Berckmans, Daniel [1 ]
Marchant-Forde, Jeremy N. [3 ]
Hartung, Joerg [4 ]
Bleich, Andre [5 ]
Lu, Mingzhou [6 ]
Norton, Tomas [1 ]
机构
[1] Katholieke Univ Leuven KU LEUVEN, Fac Biosci Engn, B-3001 Leuven, Belgium
[2] Univ Vet Med Vetmeduni Vienna, Inst Anim Welf Sci ITT, A-1210 Vienna, Austria
[3] USDA ARS, Livestock Behav Res Unit, W Lafayette, IN 47907 USA
[4] Univ Vet Med Hannover, Inst Anim Hyg Anim Welf & Farm Anim Behav, D-30625 Hannover, Germany
[5] Hannover Med Sch, Inst Lab Anim Sci & Cent Anim Facil, D-30625 Hannover, Germany
[6] Nanjing Agr Univ, Coll Engn, Jiangsu Prov Engn Lab Modern Facil Agr Technol &, Nanjing 210031, Peoples R China
来源
ANIMALS | 2021年 / 11卷 / 02期
关键词
heart rate monitoring; contactless video; single-channel signal; short-time Fourier transform; pig health and welfare;
D O I
10.3390/ani11020442
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
Simple Summary Contactless physiological monitoring can be important for animal health and well-being. The current study investigated whether heart rate in pigs can be extracted automatically from videos without disturbing the pig and showed that this was possible with 4.69 beats per minute in mean absolute error. The study also tested different body regions and found that the abdomen was a better region to measure heart rate from videos compared to the front leg or the neck. However, future studies are needed that include videos with different light conditions, different housing systems and multiple pigs to enable real-time on-farm monitoring of heart rate from videos. Heart rate (HR) is a vital bio-signal that is relatively easy to monitor with contact sensors and is related to a living organism's state of health, stress and well-being. The objective of this study was to develop an algorithm to extract HR (in beats per minute) of an anesthetized and a resting pig from raw video data as a first step towards continuous monitoring of health and welfare of pigs. Data were obtained from two experiments, wherein the pigs were video recorded whilst wearing an electrocardiography (ECG) monitoring system as gold standard (GS). In order to develop the algorithm, this study used a bandpass filter to remove noise. Then, a short-time Fourier transform (STFT) method was tested by evaluating different window sizes and window functions to accurately identify the HR. The resulting algorithm was first tested on videos of an anesthetized pig that maintained a relatively constant HR. The GS HR measurements for the anesthetized pig had a mean value of 71.76 bpm and standard deviation (SD) of 3.57 bpm. The developed algorithm had 2.33 bpm in mean absolute error (MAE), 3.09 bpm in root mean square error (RMSE) and 67% in HR estimation error below 3.5 bpm (PE3.5). The sensitivity of the algorithm was then tested on the video of a non-anaesthetized resting pig, as an animal in this state has more fluctuations in HR than an anaesthetized pig, while motion artefacts are still minimized due to resting. The GS HR measurements for the resting pig had a mean value of 161.43 bpm and SD of 10.11 bpm. The video-extracted HR showed a performance of 4.69 bpm in MAE, 6.43 bpm in RMSE and 57% in PE3.5. The results showed that HR monitoring using only the green channel of the video signal was better than using three color channels, which reduces computing complexity. By comparing different regions of interest (ROI), the region around the abdomen was found physiologically better than the face and front leg parts. In summary, the developed algorithm based on video data has potential to be used for contactless HR measurement and may be applied on resting pigs for real-time monitoring of their health and welfare status, which is of significant interest for veterinarians and farmers.
引用
收藏
页码:1 / 14
页数:14
相关论文
共 50 条
  • [21] Video-based heart rate monitoring across a range of skin pigmentations during an acute hypoxic challenge
    Addison, Paul S.
    Jacquel, Dominique
    Foo, David M. H.
    Borg, Ulf R.
    [J]. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2018, 32 (05) : 871 - 880
  • [22] Video-based heart rate monitoring across a range of skin pigmentations during an acute hypoxic challenge
    Paul S. Addison
    Dominique Jacquel
    David M. H. Foo
    Ulf R. Borg
    [J]. Journal of Clinical Monitoring and Computing, 2018, 32 : 871 - 880
  • [23] Improving Video Based Heart Rate Monitoring
    Lin, Jian
    Rozado, David
    Duenser, Andreas
    [J]. DRIVING REFORM: DIGITAL HEALTH IS EVERYONE'S BUSINESS, 2015, 214 : 146 - 151
  • [24] Video-based Noncontact Heart Rate Measurement Using Ear Features
    Cai, Xi
    Han, Guang
    Wang, Jinkuan
    [J]. PROCEEDINGS OF 2015 IEEE INTERNATIONAL CONFERENCE ON PROGRESS IN INFORMATCS AND COMPUTING (IEEE PIC), 2015, : 262 - 265
  • [25] Efficient video-based breathing pattern and respiration rate monitoring for remote health monitoring
    Siam, Ali, I
    El-Bahnasawy, Nirmeen A.
    El Banby, Ghada M.
    Abou Elazm, Atef
    Abd El-Samie, Fathi E.
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2020, 37 (11) : C118 - C124
  • [26] Video-Based Heart Rate Measurement: Recent Advances and Future Prospects
    Chen, Xun
    Cheng, Juan
    Song, Rencheng
    Liu, Yu
    Ward, Rabab
    Wang, Z. Jane
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2019, 68 (10) : 3600 - 3615
  • [27] Contactless Heart Rate Monitor for Multiple Persons in a Video
    Nisar, Humaira
    Khan, Muhammad Burhan
    Yi, Wong Ting
    Voon, Yap Vooi
    Khang, Teoh Shen
    [J]. 2016 IEEE INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS-TAIWAN (ICCE-TW), 2016, : 201 - 202
  • [28] A review of video-based pig behavior recognition
    Yang, Qiumei
    Xiao, Deqin
    [J]. APPLIED ANIMAL BEHAVIOUR SCIENCE, 2020, 233
  • [29] Video-based traffic monitoring system
    Chang, ECP
    [J]. ENHANCED AND SYNTHETIC VISION 1998, 1998, 3364 : 273 - 277
  • [30] Distributed monitoring and a video-based toolset
    Xiao, Y
    Seagull, FJ
    Hu, P
    Mackenzie, CF
    Gilbert, TB
    [J]. 2003 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN AND CYBERNETICS, VOLS 1-5, CONFERENCE PROCEEDINGS, 2003, : 1778 - 1783