Evaluation of Multifrequency Bioelectrical Impedance Analysis in Assessing Body Composition of Wrestlers

被引:34
|
作者
Utter, Alan C. [1 ]
Lambeth, Pamela G. [1 ]
机构
[1] Appalachian State Univ, Dept Hlth Leisure & Exercise Sci, Boone, NC 28608 USA
来源
关键词
WRESTLING; FAT-FREE MASS; MINIMUM WRESTLING WEIGHT; BODY FAT; BIOELECTRICAL IMPEDANCE; HIGH-SCHOOL WRESTLERS; TO-LEG BIA; COLLEGIATE WRESTLERS; MINIMUM WEIGHT; HYDRATION STATUS; BIOIMPEDANCE; PREDICTION; FAT; ULTRASOUND; VOLUME;
D O I
10.1249/MSS.0b013e3181b2e8b4
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
UTTER, A. C. and P. G. LAMBETH. Evaluation of Multifrequency Bioelectrical Impedance Analysis in Assessing Body Composition of Wrestlers. Med. Sci. Sports Exerc., Vol. 42, No. 2, pp. 361-367, 2010. Purpose: To evaluate the accuracy of multifrequency bioelectrical impedance analysis (MFBIA) in assessing fat-free mass (FFM) in comparison with hydrostatic weighing (HW) and skinfolds (SK) in high school wrestlers in a hydrated state. Methods: Body composition was determined by MFBIA, HW, and three-site SK in 72 high school wrestlers (mean +/- SD; age = 15.3 +/- 1.4 yr, height = 1.71 +/- 0.08 in, body mass = 67.3 +/- 13.4 kg). Hydration state was quantified by evaluating urine specific gravity. Results: There were no significant differences for estimated FFM between MFBIA (57.2 +/- 9.5 kg) and HW (57.0 +/- 10.1 kg) or SK (56.4 +/- 8.8 kg). The SEE for FFM with HW as the reference method were 2.73 kg for MFBIA and 2.66 kg for SK. Correlations were found for FFM between HW and MFBIA (r = 0.96, P < 0.001) and between HW and SK (r = 0.97, P < 0.001). A systematic bias was found for MFBIA because the difference between MFBIA and HW correlated with the FFM average of the two methods (r = -0.22, P < 0.001). A bias was also seen between SK and HW and correlated with the FFM average (r = -0.47, P < 0.001). Conclusions: This study demonstrates that MFBIA provides similar estimates of FFM when compared with HW in a heterogeneous high school wrestling population during a hydrated state. MFBIA is an attractive assessment tool, easy to use, and may be considered as an alternative field-based method of estimating the FFM of high school wrestlers.
引用
收藏
页码:361 / 367
页数:7
相关论文
共 50 条
  • [41] Evaluation Of Multi-frequency Bia In Assessing Body Composition Of Wrestlers
    Utter, Alan C.
    Lambeth, Pamela G.
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2010, 42 (05): : 129 - 129
  • [42] MULTIFREQUENCY BIOELECTRICAL-IMPEDANCE FOR ASSESSING TOTAL-BODY WATER AND EXTRACELLULAR WATER IN ELDERLY SUBJECTS
    VISSER, M
    DEURENBERG, P
    VANSTAVEREN, WA
    [J]. EUROPEAN JOURNAL OF CLINICAL NUTRITION, 1995, 49 (04) : 256 - 266
  • [43] BIOELECTRICAL IMPEDANCE ANALYSIS AS A METHOD TO ASSESS BODY-COMPOSITION
    LAWLOR, MR
    CRISMAN, RP
    HODGDON, JA
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1985, 17 (02): : 271 - 272
  • [44] Qualitative human body composition analysis assessed with bioelectrical impedance
    Talluri, T
    [J]. COLLEGIUM ANTROPOLOGICUM, 1998, 22 (02) : 427 - 432
  • [45] The use of bioelectrical impedance analysis for body composition in epidemiological studies
    A Böhm
    B L Heitmann
    [J]. European Journal of Clinical Nutrition, 2013, 67 : S79 - S85
  • [46] Body composition by bioelectrical impedance analysis in renal transplant recipients
    Wong, HS
    Boey, LM
    Morad, Z
    [J]. TRANSPLANTATION PROCEEDINGS, 2004, 36 (07) : 2186 - 2187
  • [47] MEASUREMENT OF BODY-COMPOSITION USING BIOELECTRICAL IMPEDANCE ANALYSIS
    LUBANSKI, RE
    KURZER, M
    MEGUID, MM
    [J]. CLINICAL RESEARCH, 1987, 35 (03): : A775 - A775
  • [48] Applications of bioelectrical impedance analysis for body composition to epidemiologic studies
    Roubenoff, R
    [J]. AMERICAN JOURNAL OF CLINICAL NUTRITION, 1996, 64 (03): : 459 - 462
  • [49] The use of bioelectrical impedance analysis for body composition in epidemiological studies
    Bohm, A.
    Heitmann, B. L.
    [J]. EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2013, 67 : S79 - S85
  • [50] Assessment of body composition in elderly:: Accuracy of bioelectrical impedance analysis
    Bussolotto, M
    Ceccon, A
    Sergi, G
    Giantin, V
    Benincà, P
    Enzi, G
    [J]. GERONTOLOGY, 1999, 45 (01) : 39 - 43