The Influence of Temporal Resolution in Determining Pharmacokinetic Parameters From DCE-MRI Data

被引:62
|
作者
Heisen, Marieke [1 ]
Fan, Xiaobing [2 ]
Buurman, Johannes [3 ]
van Riel, Natal A. W.
Karczmar, Gregory S. [2 ]
Romeny, Bart M. ter Haar
机构
[1] Eindhoven Univ Technol, Dept Biomed Engn, Sect Biomed Image Anal, NL-5600 MB Eindhoven, Netherlands
[2] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
[3] Philips Healthcare, Healthcare Informat, Best, Netherlands
关键词
DCE-MRI; temporal resolution; k-space data; pharmacokinetic model; downsampling; CONTRAST-ENHANCED MRI; T-1-WEIGHTED MRI; BREAST; TRACER; TUMORS;
D O I
10.1002/mrm.22171
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We investigated the influence of the temporal resolution of dynamic contrast-enhanced MRI data on pharmacokinetic parameter estimation. Dynamic Gd-DTPA (Gadolinium-diethylene triamine pentaacetic acid) enhanced MRI data of implanted prostate tumors on rat hind limb were acquired at 4.7 T, with a temporal resolution of similar to 5 sec. The data were subsequently downsampled to temporal resolutions in the range of 15 sec to 85 sec, using a strategy that involves a recombination of k-space data. A basic two-compartment model was fit to the contrast agent uptake curves. The results demonstrated that as temporal resolution decreases, the volume transfer constant (K(trans)) is progressively underestimated (similar to 4% to similar to 25%), and the fractional extravascular extracellular space (v(e)) is progressively overestimated (similar to 1% to similar to 10%). The proposed downsampling strategy simulates the influence of temporal resolution more realistically than simply downsampling by removing samples. Magn Reson Med 63:811-816, 2010. (C) 2010 Wiley-Liss, Inc.
引用
收藏
页码:811 / 816
页数:6
相关论文
共 50 条
  • [1] Maximum Entropy Technique and Regularization Functional for Determining the Pharmacokinetic Parameters in DCE-MRI
    Farsani, Zahra Amini
    Schmid, Volker J.
    [J]. JOURNAL OF DIGITAL IMAGING, 2022, 35 (05) : 1176 - 1188
  • [2] Maximum Entropy Technique and Regularization Functional for Determining the Pharmacokinetic Parameters in DCE-MRI
    Zahra Amini Farsani
    Volker J Schmid
    [J]. Journal of Digital Imaging, 2022, 35 : 1176 - 1188
  • [3] Influence of temporal parameters of DCE-MRI on the quantification of heterogeneity in tumor vascularization
    Crombe, Amandine
    Saut, Olivier
    Guigui, Jerome
    Italiano, Antoine
    Buy, Xavier
    Kind, Michele
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 50 (06) : 1773 - 1788
  • [4] Blind estimation of pharmacokinetic parameters in cardiac DCE-MRI
    Jacob Fluckiger
    Matthias Schabel
    Edward DiBella
    [J]. Journal of Cardiovascular Magnetic Resonance, 12 (Suppl 1)
  • [5] Characterizing Errors in Pharmacokinetic Parameters from Analyzing Quantitative Abbreviated DCE-MRI Data in Breast Cancer
    Slavkova, Kalina P.
    DiCarlo, Julie C.
    Kazerouni, Anum S.
    Virostko, John
    Sorace, Anna G.
    Patt, Debra
    Goodgame, Boone
    Yankeelov, Thomas E.
    [J]. TOMOGRAPHY, 2021, 7 (03) : 253 - 267
  • [6] ROBUST ESTIMATION OF PHARMACOKINETIC PARAMETERS IN DCE-MRI ANALYSIS OF RECTAL TUMOURS
    Tanner, L. N.
    Hughes, N. P.
    Brady, Michael
    Anderson, M.
    Gleeson, F. V.
    [J]. 2009 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1 AND 2, 2009, : 69 - +
  • [7] Temporal Resolution and SNR Requirements for Accurate DCE-MRI Data Analysis Using the AATH Model
    Kershaw, Lucy E.
    Cheng, Hai-Ling Margaret
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (06) : 1772 - 1780
  • [8] Temporal Huber Regularization for DCE-MRI
    Matti Hanhela
    Mikko Kettunen
    Olli Gröhn
    Marko Vauhkonen
    Ville Kolehmainen
    [J]. Journal of Mathematical Imaging and Vision, 2020, 62 : 1334 - 1346
  • [9] Temporal Huber Regularization for DCE-MRI
    Hanhela, Matti
    Kettunen, Mikko
    Grohn, Olli
    Vauhkonen, Marko
    Kolehmainen, Ville
    [J]. JOURNAL OF MATHEMATICAL IMAGING AND VISION, 2020, 62 (09) : 1334 - 1346
  • [10] Temporal Huber Regularization for DCE-MRI
    Hanhela, Matti
    Kettunen, Mikko
    Gröhn, Olli
    Vauhkonen, Marko
    Kolehmainen, Ville
    [J]. Hanhela, Matti (mattihan@uef.fi), 1600, Springer (62): : 1334 - 1346