Direct parametric reconstruction in dynamic PET myocardial perfusion imaging: in vivo studies

被引:7
|
作者
Petibon, Yoann [1 ,2 ]
Rakvongthai, Yothin [3 ]
El Fakhri, Georges [1 ,2 ]
Ouyang, Jinsong [1 ,2 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Gordon Ctr Med Imaging, Boston, MA USA
[2] Harvard Med Sch, Dept Radiol, Boston, MA USA
[3] Chulalongkorn Univ, Div Nucl Med, Dept Radiol, Fac Med, Bangkok, Thailand
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2017年 / 62卷 / 09期
关键词
direct parametric reconstruction; dynamic PET; myocardial perfusion imaging; kinetic modeling; parametric imaging; preconditioned conjugate gradient; POSITRON-EMISSION-TOMOGRAPHY; BLOOD-FLOW; IMAGES; MR; 3D; QUANTIFICATION; ALGORITHMS; CARDIOLOGY; HEART; MODEL;
D O I
10.1088/1361-6560/aa6394
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Dynamic PET myocardial perfusion imaging (MPI) used in conjunction with tracer kinetic modeling enables the quantification of absolute myocardial blood flow (MBF). However, MBF maps computed using the traditional indirect method (i.e. post-reconstruction voxel-wise fitting of kinetic model to PET time-activity-curves-TACs) suffer from poor signal-to-noise ratio (SNR). Direct reconstruction of kinetic parameters from raw PET projection data has been shown to offer parametric images with higher SNR compared to the indirect method. The aim of this study was to extend and evaluate the performance of a direct parametric reconstruction method using in vivo dynamic PET MPI data for the purpose of quantifying MBF. Dynamic PET MPI studies were performed on two healthy pigs using a Siemens Biograph mMR scanner. List-mode PET data for each animal were acquired following a bolus injection of similar to 7-8 mCi of F-18-flurpiridaz, a myocardial perfusion agent. Fully-3D dynamic PET sinograms were obtained by sorting the coincidence events into 16 temporal frames covering similar to 5 min after radiotracer administration. Additionally, eight independent noise realizations of both scans-each containing 1/8th of the total number of events-were generated from the original list-mode data. Dynamic sinograms were then used to compute parametric maps using the conventional indirect method and the proposed direct method. For both methods, a one-tissue compartment model accounting for spillover from the left and right ventricle blood-pools was used to describe the kinetics of F-18-flurpiridaz. An imagederived arterial input function obtained from a TAC taken in the left ventriclecavity was used for tracer kinetic analysis. For the indirect method, frame-byframe images were estimated using two fully-3D reconstruction techniques: the standard ordered subset expectation maximization (OSEM) reconstruction algorithm on one side, and the one-step late maximum a posteriori (OSL-MAP) algorithm on the other side, which incorporates a quadratic penalty function. The parametric images were then calculated using voxel-wise weighted leastsquare fitting of the reconstructed myocardial PET TACs. For the direct method, parametric images were estimated directly from the dynamic PET sinograms using a maximum a posteriori ( MAP) parametric reconstruction algorithm which optimizes an objective function comprised of the Poisson log-likelihood term, the kinetic model and a quadratic penalty function. Maximization of the objective function with respect to each set of parameters was achieved using a preconditioned conjugate gradient algorithm with a specifically developed preconditioner. The performance of the direct method was evaluated by comparing voxel-and segment-wise estimates of K1, the tracer transport rate (ml min(-1) ml(-1)), to those obtained using the indirect method applied to both OSEM and OSL-MAP dynamic reconstructions. The proposed direct reconstruction method produced K-1 maps with visibly lower noise than the indirect method based on OSEM and OSL-MAP reconstructions. At normal count levels, the direct method was shown to outperform the indirect method based on OSLMAP in the sense that at matched level of bias, reduced regional noise levels were obtained. At lower count levels, the direct method produced K-1 estimates with significantly lower standard deviation across noise realizations than the indirect method based on OSL-MAP at matched bias level. In all cases, the direct method yielded lower noise and standard deviation than the indirect method based on OSEM. Overall, the proposed direct reconstruction offered a better bias-variance tradeoff than the indirect method applied to either OSEM and OSL-MAP. Direct parametric reconstruction as applied to in vivo dynamic PET MPI data is therefore a promising method for producing MBF maps with lower variance.
引用
收藏
页码:3539 / 3565
页数:27
相关论文
共 50 条
  • [21] Use of dynamic reconstruction for parametric Patlak imaging in dynamic whole body PET
    Chalampalakis, Zacharias
    Stute, Simon
    Filipovic, Marina
    Sureau, Florent
    Comtat, Claude
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (18):
  • [22] A comparison of numerical methods for parametric imaging of canine myocardial perfusion by dynamic N-13 ammonia PET.
    Golish, SR
    Hove, JD
    Schelbert, HR
    Gambhir, SS
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 99P - 99P
  • [23] Anatomy-assisted direct 4D parametric image reconstruction for dynamic cardiac PET imaging
    Deng, Wei
    Wang, Xinhui
    Tang, Jing
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [24] Generalized Algorithms for Direct Reconstruction of Parametric Images From Dynamic PET Data
    Wang, Guobao
    Qi, Jinyi
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (11) : 1717 - 1726
  • [25] Direct Parametric Reconstruction for Improved Characterization of Neurotransmitter Release using Dynamic PET
    Petibon, Yoann
    Alpert, Nathaniel
    Ouyang, Jinsong
    Cheung, Joey
    Kang, Min Su
    Hooker, Jacob
    Pizzagalli, Diego
    Cusin, Cristina
    Fava, Maurizio
    El Fakhri, Georges
    Normandin, Marc
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [26] DIRECT RECONSTRUCTION OF DYNAMIC PET PARAMETRIC IMAGES USING SPARSE SPECTRAL REPRESENTATION
    Wang, Guobao
    Qi, Jinyi
    [J]. 2009 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1 AND 2, 2009, : 867 - 870
  • [27] Dynamic PET Image Reconstruction for Parametric Imaging Using the HYPR Kernel Method
    Spencer, Benjamin
    Qi, Jinyi
    Badawi, Ramsey D.
    Wang, Guobao
    [J]. MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [28] Prediction of angiogenesis based on dynamic PET FDG studies and parametric imaging
    Strauss, Ludwig
    Pan, Leyun
    Cheng, Caixia
    Haberkorn, Uwe
    Dimitrakopoulou-Strauss, Antonia
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [29] Study of the Effect of Reconstruction Parameters for Myocardial Perfusion Imaging in PET With a Novel Flow Phantom
    Siekkinen, Reetta
    Teuho, Jarmo
    Smith, Nadia A. S.
    Fenwick, Andrew
    Kirjavainen, Anna K.
    Koskensalo, Kalle
    Saraste, Antti
    Teras, Mika
    [J]. FRONTIERS IN PHYSICS, 2020, 8 (08):
  • [30] Direct Parametric Reconstruction With Joint Motion Estimation/Correction for Dynamic Brain PET Data
    Jiao, Jieqing
    Bousse, Alexandre
    Thielemans, Kris
    Burgos, Ninon
    Weston, Philip S. J.
    Schott, Jonathan M.
    Atkinson, David
    Arridge, Simon R.
    Hutton, Brian F.
    Markiewicz, Pawel
    Ourselin, Sebastien
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (01) : 203 - 213