Fixation Characteristics of Severe Amblyopia with Eccentric Fixation and Central Fixation Assessed by the MP-1 Microperimeter

被引:8
|
作者
Wang, Shu [1 ,2 ,3 ,4 ]
Tian, Tian [1 ,2 ,3 ,4 ]
Zou, Leilei [1 ,2 ,3 ,4 ]
Wu, Sujia [1 ,2 ,3 ,4 ]
Liu, Yan [1 ,2 ,3 ,4 ]
Wen, Wen [1 ,2 ,3 ,4 ]
Liu, Hong [1 ,2 ,3 ,4 ,5 ]
机构
[1] Fudan Univ, Shanghai Med Coll, Eye & ENT Hosp, Dept Ophthalmol & Visual Sci, Shanghai, Peoples R China
[2] Fudan Univ, Inst Brain Sci, State Key Lab Med Neurobiol, Shanghai, Peoples R China
[3] Fudan Univ, Minist Hlth, Key Lab Myopia, Shanghai, Peoples R China
[4] Fudan Univ, Shanghai Key Lab Visual Impairment & Restorat, Shanghai, Peoples R China
[5] Shanghai Jiao Tong Univ, Sch Med, Shanghai Childrens Med Ctr, Dept Ophthalmol, Shanghai, Peoples R China
关键词
Amblyopia; eccentric fixation; fixation location; fixation stability; MP-1; microperimeter;
D O I
10.1080/08820538.2021.1890142
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objectives: To investigate the fixation patterns in severe amblyopia with eccentric or central fixation by the MP-1 microperimeter. Design: Fixation test was performed on 38 patients with severe amblyopia using the MP-1 microperimeter, 20 patients with eccentric fixation (EF group), and 18 patients with central fixation (CF group). Fixation location and fixation stability were quantified by preferred fixation eccentricity and bivariate contour ellipse area (BCEA, deg(2)) respectively. Comparisons of BCEA between amblyopic and fellow eyes (FE) in both groups and between amblyopic eyes (AE) in both groups were analyzed. Linear regression analysis was used to investigate the risk factors for fixation instability in patients with eccentric fixation. Results: In EF group, the BCEA of AE was 14.68 +/- 19.21 deg(2), which was significantly larger than that of FE (1.294 +/- 1.840, F = 9.243, p = .007). Linear regression analysis showed that only preferred fixation eccentricity (beta = 6.536, 95% CI: 2.665 similar to 10.406, p < .005) was correlated with BCEA of AE. The BCEA of AE in the EF group was significantly larger than that of AE in the CF group (4.95 +/- 3.44 deg(2), t = 2.227,p < .05), although the BCVA was not significantly different between two groups (t = 0.129, p = .898). Conclusions: The fixation ability in amblyopia with eccentric fixation was found to be significantly worse than those with central fixation and preferred fixation eccentricity was the only predictor for the instability. MP-1 is an effective tool to quantify fixation features for diagnosis and follow-up of eccentric amblyopia patients.
引用
收藏
页码:360 / 365
页数:6
相关论文
共 50 条
  • [21] Evaluation of fixation stability using different targets with the MP1 microperimeter
    Cesareo, M.
    Manca, D.
    Ciuffoletti, E.
    De Giovanni, V.
    Ricci, F.
    Nucci, C.
    Cerulli, L.
    INTERNATIONAL OPHTHALMOLOGY, 2015, 35 (01) : 11 - 17
  • [22] The Evaluation of Fixation Pattern with MP-1 Microperimetry in Eyes with Stargardt Disease
    Senturk, Fevzi
    Ozdemir, Hakan
    Karacorlu, Serra Arf
    Karacorlu, Murat
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2008, 38 (02): : 134 - 138
  • [23] Evaluation of fixation stability using different targets with the MP1 microperimeter
    M. Cesareo
    D. Manca
    E. Ciuffoletti
    V. De Giovanni
    F. Ricci
    C. Nucci
    L. Cerulli
    International Ophthalmology, 2015, 35 : 11 - 17
  • [24] Relationship between fixation stability measured with MP-1 and reading performance
    Amore, Filippo M.
    Fasciani, Romina
    Silvestri, Valeria
    Crossland, Michael D.
    de Waure, Chiara
    Cruciani, Filippo
    Reibaldi, Alfredo
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2013, 33 (05) : 611 - 617
  • [25] Fixation Characteristics of Severe Amblyopia Subtypes: Which One is Worse?
    Koylu, Mehmet Talay
    Ozge, Gokhan
    Kucukevcilioglu, Murat
    Mutlu, Fatih Mehmet
    Ceylan, Osman Melih
    Akincioglu, Dorukcan
    Ayyildiz, Onder
    SEMINARS IN OPHTHALMOLOGY, 2017, 32 (05) : 553 - 558
  • [26] Electronically monitored occlusion therapy in amblyopia with eccentric fixation
    Berna Mehmed
    Maria Fronius
    Tabea Pohl
    Hanns Ackermann
    Charlotte Schramm
    Bettina Spieth
    Christian Hofmann
    Thomas Kohnen
    Yaroslava Wenner
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2022, 260 : 1741 - 1753
  • [27] AMBLYOPIA, ECCENTRIC FIXATION, AND STILES-CRAWFORD EFFECT
    MARSHALL, RL
    FLOM, MC
    AMERICAN JOURNAL OF OPTOMETRY AND ARCHIVES OF AMERICAN ACADEMY OF OPTOMETRY, 1970, 47 (02): : 81 - &
  • [28] Electronically monitored occlusion therapy in amblyopia with eccentric fixation
    Mehmed, Berna
    Fronius, Maria
    Pohl, Tabea
    Ackermann, Hanns
    Schramm, Charlotte
    Spieth, Bettina
    Hofmann, Christian
    Kohnen, Thomas
    Wenner, Yaroslava
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 260 (05) : 1741 - 1753
  • [30] ECCENTRIC FIXATION IN AMBLYOPIA - IS REDUCED FOVEAL ACUITY CAUSE
    FLOM, MC
    AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1978, 55 (03): : 139 - 143