Twelve-month follow-up of left atrial appendage occlusion with Amplatzer Amulet

被引:29
|
作者
Kleinecke, Caroline [1 ]
Park, Jai-Wun [1 ]
Goedde, Martin [1 ]
Zintl, Konstantin [1 ]
Schnupp, Steffen [1 ]
Brachmann, Johannes [1 ]
机构
[1] Klinikum Coburg, Med Clin Cardiol Intens Care Med 2, Ketschendorfer Str 33, D-96450 Coburg, Germany
关键词
left atrial appendage occlusion; Amplatzer Amulet; atrial fibrillation; stroke prophylaxis; CARDIAC PLUG; INITIAL-EXPERIENCE; WARFARIN THERAPY; CLOSURE; FIBRILLATION; DEVICE; STROKE;
D O I
10.5603/CJ.a2017.0017
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The Amplatzer Amulet (St. Jude Medical, Minneapolis, MN, USA) is a second generation Amplatzer device for left atrial appendage (LAA) occlusion (LAAO) for stroke prophylaxis in patients with atrial fibrillation. This research sought to assess the clinical performance of the Amplatzer Amulet device and in follow up for 12 months. Methods: In this single-center registry patients with atrial fibrillation and contraindication to oral anticoagulation underwent LAAO with the Amplatzer Amulet device. Follow-up was performed before discharge, by transesophageal echocardiography (TEE) after 6 weeks and telephone interview after 3, 6 and 12 months. Results: Between October 2014 and August 2015 50 patients (76.1 +/- 8.3 years; 30 male) were enrolled. Procedural success was achieved in 49 (98%) patients. Major periprocedural adverse events were observed in 4 (8%) of patients: 1 device embolization, 2 pericardial effusions requiring pericardiocentesis and 1 prolonged hospital stay due to retropharyngeal hematoma from the TEE probe. Follow-up TEE was available in 38 of 50 patients showing complete LAA sealing in all. 2 device-related thrombi were also documented. At 12-month follow-up 7 patients had died unrelated to the device. Ischemic stroke occurred in 3 patients. According to neurological examination two were classified as microangiopathic and not cardio-embolic. The other one could not be classified. Bleeding complications (5 minor, 3 major) were documented in 8 patients. Conclusions: Although minimizing procedure-related complications remains challenging, LAAO with the Amplatzer Amulet device showed high procedural success and excellent LAA sealing.
引用
收藏
页码:131 / 138
页数:8
相关论文
共 50 条
  • [41] Improving cardiac resynchronization therapy response with multipoint left ventricular pacing: Twelve-month follow-up study
    Pappone, Carlo
    Calovic, Zarko
    Vicedomini, Gabriele
    Cuko, Amarild
    McSpadden, Luke C.
    Ryu, Kyungmoo
    Jordan, Caroline D.
    Romano, Enrico
    Baldi, Mario
    Saviano, Massimo
    Pappone, Alessia
    Vitale, Raffaele
    Catalano, Concetto
    Ciaccio, Cristiano
    Giannelli, Luigi
    Ionescu, Bogdan
    Petretta, Andrea
    Fragakis, Nikolaos
    Fundaliotis, Angelica
    Tavazzi, Luigi
    Santinelli, Vincenzo
    HEART RHYTHM, 2015, 12 (06) : 1250 - 1258
  • [42] Closure of Left Atrial Appendage With Persistent Distal Thrombus Using an Amplatzer Amulet Occluder
    Lange, Mathias
    Bueltel, Helmut
    Weglage, Heinrich
    Loeffeld, Patrick
    Wichter, Thomas
    JOURNAL OF INVASIVE CARDIOLOGY, 2016, 28 (09): : E75 - E76
  • [43] Correction to: Left atrial appendage sealing performance of the Amplatzer Amulet and Watchman FLX device
    Kasper Korsholm
    Anders Kramer
    Asger Andersen
    Jacqueline Saw
    Bjarne Linde Nørgaard
    Jesper Møller Jensen
    Jens Erik Nielsen-Kudsk
    Journal of Interventional Cardiac Electrophysiology, 2023, 66 : 403 - 403
  • [44] Left atrial appendage closure with the Amplatzer™ Cardiac Plug: Impact of shape and device sizing on follow-up leaks
    Freixa, Xavier
    Tzikas, Apostolos
    Sobrino, Ayax
    Chan, Jason
    Basmadjian, Arsene J.
    Ibrahim, Reda
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 168 (02) : 1023 - 1027
  • [45] Cardiac Computed Tomography Follow-up of Left Atrial Appendage Exclusion Using the Amplatzer Cardiac Plug Device
    Poulter, Rohan S.
    Tang, Jonathon
    Jue, John
    Ibrahim, Reda
    Nicolaou, Savvas
    Mayo, John
    Saw, Jacqueline
    CANADIAN JOURNAL OF CARDIOLOGY, 2012, 28 (01) : 119.e1 - 119.e3
  • [46] LEFT ATRIAL APPENDAGE CLOSURE WITH THE AMPLATZER CARDIAC PLUG: IMPACT OF SHAPE AND DEVICE SIZING ON FOLLOW-UP LEAKS
    Freixa, X.
    Tzikas, A.
    Sobrino, A.
    Chan, J.
    Basmadjian, A.
    Ibrahim, R.
    CANADIAN JOURNAL OF CARDIOLOGY, 2012, 28 (05) : S234 - S234
  • [47] Serial echocardiographic follow-up of percutaneous left atrial appendage transcatheter occlusion (PLAATO™) in patients with atrial fibrillation
    Poppas, A
    Nakai, T
    Sievert, H
    Crouse, L
    Macrum, BL
    Krabill, K
    Gan, S
    Martin, R
    Omran, H
    Pepi, M
    Sgura, F
    Seiler, C
    Clarke, L
    Kutnick, R
    Rubenson, D
    Dias, B
    Reisman, M
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 348A - 349A
  • [48] COMPARATIVE EFFICACY AND SAFETY OF AMPLATZER AMULET VS WATCHMAN FOR LEFT ATRIAL APPENDAGE OCCLUSION: A SYSTEMATIC REVIEW AND META-ANALYSIS
    Farooq, Omer
    Ghani, Usman
    Akbar, Muhammad Sikander
    Saudye, Hammad
    Mutti, Sumeet
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 83 (13) : 47 - 47
  • [49] Follow-up imaging after left atrial appendage closure
    Kuroki, Kenji
    Doshi, Shephal K.
    Whang, William
    Vanderzee, Sarina
    Ducharme, Crystal B.
    Enomoto, Yoshinari
    Hanon, Sam
    Koruth, Jacob S.
    Miller, Marc A.
    Choudry, Subbarao
    Sofi, Aamir
    Langan, Noelle
    Ellsworth, Betsy
    Dukkipati, Srinivas R.
    Reddy, Vivek Y.
    HEART RHYTHM, 2020, 17 (11) : 1848 - 1855
  • [50] Follow-up imaging of a left atrial appendage closure device
    Di Biase, Luigi
    Horton, Rodney
    Wang, Yan
    Natale, Andrea
    HEART RHYTHM, 2009, 6 (12) : 1837 - 1838