Smartwatch feedback device for high-quality chest compressions by a single rescuer during infant cardiac arrest: a randomized, controlled simulation study

被引:16
|
作者
Lee, Juncheol [1 ]
Song, Yeongtak [2 ]
Oh, Jaehoon [1 ,2 ]
Chee, Youngjoon [3 ]
Ahn, Chiwon [1 ]
Shin, Hyungoo [1 ]
Kang, Hyunggoo [1 ,2 ]
Lim, Tae Ho [1 ,2 ]
机构
[1] Hanyang Univ, Dept Emergency Med, Coll Med, 222 Wangsimni Ro, Seoul 04763, South Korea
[2] Hanyang Univ, Convergence Technol Ctr Disaster Preparedness, Seoul, South Korea
[3] Univ Ulsan, Sch Elect Engn, Ulsan, South Korea
基金
新加坡国家研究基金会;
关键词
application; cardiopulmonary resuscitation; paediatric basic life support; smartwatch; CARDIOPULMONARY-RESUSCITATION; CPR PERFORMANCE; DEPTH; SMARTPHONE; EPIDEMIOLOGY; IMPROVEMENT; GUIDELINES; SUPPORT;
D O I
10.1097/MEJ.0000000000000537
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective According to the guidelines, rescuers should provide chest compressions (CC) similar to 1.5 inches (40 mm) for infants. Feedback devices could help rescuers perform CC with adequate rates (CCR) and depths (CCD). However, there is no CC feedback device for infant cardiopulmonary resuscitation (CPR). We suggest a smartwatch-based CC feedback application for infant CPR. Participants and methods We created a smartwatch-based CC feedback application. This application provides feedback on CCD and CCR by colour and text for infant CPR. To evaluate the application, 30 participants were divided randomly into two groups on the basis of whether CC was performed with or without the assistance of the smartwatch application. Both groups performed continuous CC-only CPR for 2 min on an infant mannequin placed on a firm table. We collected CC parameters from the mannequin, including the proportion of correct depth, CCR, CCD and the proportion of correct decompression depth. Results Demographics between the two groups were not significantly different. The median (interquartile range) proportion of correct depth was 99 (97-100) with feedback compared with 83 (58-97) without feedback (P = 0.002). The CCR and proportion of correct decompression depth were not significantly different between the two groups (P = 0.482 and 0.089). The CCD of the feedback group was significantly deeper than that of the control group [ feedback vs. control: 41.2 (39.8-41.7) mm vs. 38.6 (36.1-39.6) mm; P= 0.004]. Conclusion Rescuers who receive feedback of CC parameters from a smartwatch could perform adequate CC during infant CPR. European Journal of Emergency Medicine 26: 266-271 Copyright (c) 2018 The Author(s). Published by Wolters Kluwer Health, Inc.
引用
收藏
页码:266 / 271
页数:6
相关论文
共 36 条
  • [31] Verbal Motivation vs. Digital Real-Time Feedback during Cardiopulmonary Resuscitation: Comparing Bystander CPR Quality in a Randomized and Controlled Manikin Study of Simulated Cardiac Arrest
    Plata, Christopher
    Nowack, Michael
    Loeser, Johannes
    Drinhaus, Hendrik
    Steinhauser, Susanne
    Hinkelbein, Jochen
    Wetsch, Wolfgang A.
    Boettiger, Bernd W.
    Spelten, Oliver
    PREHOSPITAL EMERGENCY CARE, 2021, 25 (03) : 377 - 387
  • [32] A remote-controlled automatic chest compression device capable of moving compression position during CPR: A pilot study in a mannequin and a swine model of cardiac arrest
    Suh, Gil Joon
    Kim, Taegyun
    Kim, Kyung Su
    Kwon, Woon Yong
    Kim, Hayoung
    Park, Heesu
    Wang, Gaonsorae
    Park, Jaeheung
    Hur, Sungmoon
    Sim, Jaehoon
    Kim, Kyunghwan
    Lee, Jung Chan
    Shin, Dong Ah
    Cho, Woo Sang
    Kim, Byung Jun
    Kwon, Soyoon
    Lee, Ye Ji
    PLOS ONE, 2024, 19 (01):
  • [33] Effect of a Real-Time Audio Ventilation Feedback Device on the Survival Rate and Outcomes of Patients with Out-of-Hospital Cardiac Arrest: A Prospective Randomized Controlled Study
    Lee, Eun Dong
    Jang, Yun Deok
    Kang, Ji Hun
    Seo, Yong Song
    Yoon, Yoo Sang
    Kim, Yang Weon
    Jeong, Woong Bin
    Ji, Jae Gu
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (18)
  • [34] Effect on Chest Compression Fraction of Continuous Manual Compressions with Asynchronous Ventilations Using an i-gel(R) versus 30:2 Approach during Simulated Out-of-Hospital Cardiac Arrest: Protocol for a Manikin Multicenter Randomized Controlled Trial
    Stuby, Loric
    Jampen, Laurent
    Sierro, Julien
    Paus, Erik
    Spichiger, Thierry
    Suppan, Laurent
    Thurre, David
    HEALTHCARE, 2021, 9 (03)
  • [35] Intravenous regular insulin is an efficient and safe procedure for obtaining high-quality cardiac 18F-FDG PET images: an open-label, single-center, randomized controlled prospective trial
    Yang Chun Chen
    Qing Qing Wang
    Yue Hui Wang
    Hui Lin Zhuo
    Ruo Zhu Dai
    Journal of Nuclear Cardiology, 2022, 29 : 239 - 247
  • [36] Intravenous regular insulin is an efficient and safe procedure for obtaining high-quality cardiac 18F-FDG PET images: an open-label, single-center, randomized controlled prospective trial
    Chen, Yang Chun
    Wang, Qing Qing
    Wang, Yue Hui
    Zhuo, Hui Lin
    Dai, Ruo Zhu
    JOURNAL OF NUCLEAR CARDIOLOGY, 2022, 29 (01) : 239 - 247