Evidence for selectivity of absorption of volatile organic compounds by a polydimethylsiloxane solid-phase microextraction fibre

被引:17
|
作者
Niedziella, S [1 ]
Rudkin, S [1 ]
Cooke, M [1 ]
机构
[1] Univ London Royal Holloway & Bedford New Coll, Tox Gases Res Grp, Ctr Chem Sci, Egham TW20 0EX, Surrey, England
关键词
solid-phase microextraction; selectivity; polydimethylsiloxane fibres; volatile organic compounds;
D O I
10.1016/S0021-9673(00)00109-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Solid-phase microextraction using a 30 mu m polydimethylsiloxane fibre has been used to sample the volatile organic compounds from standard mixtures and from mixtures produced by the decomposition of organic compounds. This method of sampling has been compared with the direct injection of an aliquot of headspace gas and shows an enrichment factor of approximately 100 over a 1 ml gas injection for organosulphur gases such as dimethyldisulphide. The performance of the fibre has been evaluated with respect to accuracy and precision at several concentrations in representing the composition of multicomponent mixtures. It was found that the presence of a second component in a gas sample reduced the capacity of the fibre to absorb the primary component. The selectivity of the fibre for various volatile compounds with differing functionality was also studied. It was found that the non-polar polydimethylsiloxane fibre preferentially absorbed the non-polar components of a mixture, e.g nonane and, correspondingly, under reported the more polar components, e.g. ethanol. Hence, the fibre discriminates in favour of non-polar and against polar components in a mixture in comparison with direct analysis of a headspace sample. Thus, quantitation of a component in a multi-component mixture is liable to error from competitive interference from other components. A major advantage of the technique, however, is that it does not absorb, and therefore introduce, water into the analytical system. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:457 / 464
页数:8
相关论文
共 50 条
  • [31] Solid-phase microextraction gas chromatography/mass spectrometric analysis of volatile organic compounds in water
    Bocchini, P
    Andalò, C
    Bonfiglioli, D
    Galletti, GC
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1999, 13 (21) : 2133 - 2139
  • [32] Determination of volatile organic compounds in urine by solid phase microextraction
    Ghittori, S
    Maestri, L
    Zadra, P
    Marraccini, P
    Imbriani, M
    [J]. VOLATILE ORGANIC COMPOUNDS IN THE ENVIRONMENT - RISK ASSESSMET AND NEUROTOXICITY, 1997, 3 (03): : 87 - 93
  • [33] Determination of Volatile Compounds in Sultaniye Wine by Solid-Phase Microextraction Techniques
    T. Cabaroglu
    S. Selli
    E. Kafkas
    M. Kurkcuoglu
    A. Canbas
    K. H. C. Baser
    [J]. Chemistry of Natural Compounds, 2005, 41 : 382 - 384
  • [34] SCREENING ORGANIC COMPOUNDS IN WET WIPES BY SOLID-PHASE MICROEXTRACTION
    Alimzhanova, Mereke
    Muratova, Saltanat
    Sagandykova, Gulyaim
    Ashimuly, Kazhybek
    Nauryzbayev, Michael
    [J]. ECOLOGY, ECONOMICS, EDUCATION AND LEGISLATION CONFERENCE PROCEEDINGS, SGEM 2016, VOL II, 2016, : 719 - 725
  • [35] Electromagnetically vibrated Solid-Phase Microextraction for the analysis of organic compounds
    Joo, Jin Chul
    Reardon, Kenneth F.
    Shackelford, Charles D.
    Wilmetti, Joseph F.
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL TECHNOLOGY AND MANAGEMENT, 2010, 12 (2-4) : 393 - 406
  • [36] Modeling solid-phase microextraction of volatile organic compounds by porous coatings using finite element analysis
    Kenessov, Bulat
    Derbissalin, Miras
    Koziel, Jacek A.
    Kosyakov, Dmitry S.
    [J]. ANALYTICA CHIMICA ACTA, 2019, 1076 : 73 - 81
  • [37] Studies on the application of solid-phase microextraction for analysis of volatile organic sulphur compounds in gaseous and liquid samples
    Wardencki, W
    Namiesnik, J
    [J]. CHEMIA ANALITYCZNA, 1999, 44 (03): : 485 - 493
  • [38] Pollution of ground and drinking water with volatile organic compounds: Solid-phase microextraction and GC/MS analysis
    Envtl. Pharmacology/Toxicology Lab., Mario Negri Pharmacological Inst., Milan, Italy
    [J]. TOXICOL. ENVIRON. CHEM., 1-4 (73-81):
  • [39] Sampling Dynamics for Volatile Organic Compounds Using Headspace Solid-Phase Microextraction Arrow for Microbiological Samples
    Eckert, Kevin E.
    Carter, David O.
    Perrault, Katelynn A.
    [J]. SEPARATIONS, 2018, 5 (03)
  • [40] A simple calibration procedure for volatile organic compounds sampling in air with adsorptive solid-phase microextraction fibres
    Tuduri, L
    Desauziers, V
    Fanlo, JL
    [J]. ANALYST, 2003, 128 (08) : 1028 - 1032