Reliability and validity issues of laser fluorescence measurements in occlusal caries diagnosis

被引:70
|
作者
Alwas-Danowska, HA
Plasschaert, AJM
Suliborski, S
Verdonschot, EH
机构
[1] Med Univ Lodz, Dept Propaedeut & Diagnost Stomatol, PL-92216 Lodz, Poland
[2] Univ Nijmegen, Ctr Med, Dept Cariol & Endodontol, Nijmegen, Netherlands
关键词
occlusal caries; laser fluorescence; visual inspection; diagnosis;
D O I
10.1016/S0300-5712(02)00015-5
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. Recently, a device for detecting occlusal caries lesions based on laser fluorescence measurements (DIAGNOdent(R)) has been introduced. The reliability (reproducibility) and validity of this laser-fluorescence device were investigated. Methods. In the in vitro part of the study, 49 permanent molars were measured by two observers using two DIAGNOdent(R) devices. In addition, visual inspection was performed. The teeth were sectioned to measure the actual depth and area of the caries lesions. In the in vivo part of the study, 45 sites at the occlusal surfaces of permanent molar teeth in 13 patients were measured by two observers using two DIAGNOdent(R) devices, manufactured in two successive years. Results. The reliability of both DIAGNOdent(R) devices expressed in the intraclass correlation coefficient (ICC = 0.90 for observer 1, and 0.88 for observer 2) was high, and so was the interobserver reliability (ICC = 0.85 for the 1998-device, ICC = 0.90 for the 1999-device). The correlation between DIAGNOdent(R) measurements and the actual depth of the caries lesions was lower than that of visual inspection by one observer, yet higher than that of a second observer. The specificities of visual inspection (0.94 and 0.88) were higher than those of the DIAGNOdent(R) devices, whereas the sensitivities of the DIAGNOdent(R) devices (0.93 - 1.00) exceeded those of visual inspection The validity of the DIAGNOdent(R), expressed as the area under the receiver operating characteristic curve, was not statistically significantly different from that of visual inspection (P > 0.05). The DIAGNOdent(R) measurements showed a higher association with the enamel part of the caries lesion than with the dentinal part. Conclusions. The DIAGNOdent(R) is suitable for monitoring small caries lesions. Because of the high reproducibility of DIAGNOdent(R) devices produced in successive years, a DIAGNOdent(R) device may be replaced by a new one. Due to the higher specificity, visual inspection should be preferred to diagnose occlusal caries lesions in populations with a low caries prevalence. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:129 / 134
页数:6
相关论文
共 50 条
  • [21] Performance of a new laser fluorescence device for the detection of occlusal caries in vitro
    Lussi, A.
    Hellwig, E.
    JOURNAL OF DENTISTRY, 2006, 34 (07) : 467 - 471
  • [22] Performance and reproducibility of a laser fluorescence system for detection of occlusal caries in vitro
    Lussi, A
    Imwinkelried, S
    Pitts, NB
    Longbottom, C
    Reich, E
    CARIES RESEARCH, 1999, 33 (04) : 261 - 266
  • [23] Comparison of two laser fluorescence devices for the detection of occlusal caries in vivo
    Krause, F.
    Jepsen, S.
    Braun, A.
    EUROPEAN JOURNAL OF ORAL SCIENCES, 2007, 115 (04) : 252 - 256
  • [24] Laser fluorescence system for detection of occlusal caries in third molars.
    Baseren, NM
    Gökalp, S
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 475 - 475
  • [25] Occlusal caries detection: A comparison of a laser fluorescence system and conventional methods
    Burin, C
    Burin, C
    Loguercio, AD
    Grande, RHM
    Reis, A
    PEDIATRIC DENTISTRY, 2005, 27 (04) : 307 - 312
  • [26] Comparing the reliability of a new fluorescence camera with conventional laser fluorescence devices in detecting caries lesions in occlusal and smooth surfaces of primary teeth
    Monique Saveriano De Benedetto
    Caroline Carvalho Morais
    Tatiane Fernandes Novaes
    Jonas de Almeida Rodrigues
    Mariana Minatel Braga
    Fausto Medeiros Mendes
    Lasers in Medical Science, 2011, 26 : 157 - 162
  • [27] Comparing the reliability of a new fluorescence camera with conventional laser fluorescence devices in detecting caries lesions in occlusal and smooth surfaces of primary teeth
    De Benedetto, Monique Saveriano
    Morais, Caroline Carvalho
    Novaes, Tatiane Fernandes
    Rodrigues, Jonas de Almeida
    Braga, Mariana Minatel
    Mendes, Fausto Medeiros
    LASERS IN MEDICAL SCIENCE, 2011, 26 (02) : 157 - 162
  • [28] Occlusal caries detection in permanent molars according to WHO basic methods, ICDAS II and laser fluorescence measurements
    Kuehnisch, Jan
    Berger, Susanne
    Goddon, Inka
    Senkel, Helga
    Pitts, Nigel
    Heinrich-Weltzien, Roswitha
    COMMUNITY DENTISTRY AND ORAL EPIDEMIOLOGY, 2008, 36 (06) : 475 - 484
  • [29] Validation of DIAGNOdent laser fluorescence and the International Caries Detection and Assessment System (ICDAS) in diagnosis of occlusal caries in permanent teeth: an in vivo study
    Castilho, Lia S.
    Cotta, Fernanda V. M. D.
    Bueno, Audrey C.
    Moreira, Allyson N.
    Ferreira, Efigenia F.
    Magalhaes, Claudia S.
    EUROPEAN JOURNAL OF ORAL SCIENCES, 2016, 124 (02) : 188 - 194
  • [30] Occlusal caries diagnosis and treatment
    Evans, W
    Morgan, M
    Johnson, I
    Baltutis, L
    AUSTRALIAN DENTAL JOURNAL, 1997, 42 (04) : 269 - 270