Reliability and validity issues of laser fluorescence measurements in occlusal caries diagnosis

被引:70
|
作者
Alwas-Danowska, HA
Plasschaert, AJM
Suliborski, S
Verdonschot, EH
机构
[1] Med Univ Lodz, Dept Propaedeut & Diagnost Stomatol, PL-92216 Lodz, Poland
[2] Univ Nijmegen, Ctr Med, Dept Cariol & Endodontol, Nijmegen, Netherlands
关键词
occlusal caries; laser fluorescence; visual inspection; diagnosis;
D O I
10.1016/S0300-5712(02)00015-5
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. Recently, a device for detecting occlusal caries lesions based on laser fluorescence measurements (DIAGNOdent(R)) has been introduced. The reliability (reproducibility) and validity of this laser-fluorescence device were investigated. Methods. In the in vitro part of the study, 49 permanent molars were measured by two observers using two DIAGNOdent(R) devices. In addition, visual inspection was performed. The teeth were sectioned to measure the actual depth and area of the caries lesions. In the in vivo part of the study, 45 sites at the occlusal surfaces of permanent molar teeth in 13 patients were measured by two observers using two DIAGNOdent(R) devices, manufactured in two successive years. Results. The reliability of both DIAGNOdent(R) devices expressed in the intraclass correlation coefficient (ICC = 0.90 for observer 1, and 0.88 for observer 2) was high, and so was the interobserver reliability (ICC = 0.85 for the 1998-device, ICC = 0.90 for the 1999-device). The correlation between DIAGNOdent(R) measurements and the actual depth of the caries lesions was lower than that of visual inspection by one observer, yet higher than that of a second observer. The specificities of visual inspection (0.94 and 0.88) were higher than those of the DIAGNOdent(R) devices, whereas the sensitivities of the DIAGNOdent(R) devices (0.93 - 1.00) exceeded those of visual inspection The validity of the DIAGNOdent(R), expressed as the area under the receiver operating characteristic curve, was not statistically significantly different from that of visual inspection (P > 0.05). The DIAGNOdent(R) measurements showed a higher association with the enamel part of the caries lesion than with the dentinal part. Conclusions. The DIAGNOdent(R) is suitable for monitoring small caries lesions. Because of the high reproducibility of DIAGNOdent(R) devices produced in successive years, a DIAGNOdent(R) device may be replaced by a new one. Due to the higher specificity, visual inspection should be preferred to diagnose occlusal caries lesions in populations with a low caries prevalence. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:129 / 134
页数:6
相关论文
共 50 条
  • [1] Laser fluorescence detection of occlusal caries
    Tonioli, MB
    Bouschlicher, MR
    Hillis, SL
    AMERICAN JOURNAL OF DENTISTRY, 2002, 15 (04): : 268 - 273
  • [2] Laser fluorescence detection of occlusal caries
    Tonioli, MB
    Bouschlicher, MR
    Cobb, DS
    Denehy, GE
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 558 - 558
  • [3] In vivo validity and reliability of IR fluorescence measurements for caries detection and quantification
    Tranæus, S
    Lindgren, LE
    Karlsson, L
    Angmar-Månsson, B
    SWEDISH DENTAL JOURNAL, 2004, 28 (04) : 173 - 182
  • [4] In vivo comparison of laser fluorescence measurements with conventional methods for occlusal caries detection
    Meryem Toraman Alkurt
    Ilkay Peker
    Hacer Deniz Arisu
    Oya Bala
    Bülent Altunkaynak
    Lasers in Medical Science, 2008, 23 : 307 - 312
  • [5] In vivo comparison of laser fluorescence measurements with conventional methods for occlusal caries detection
    Alkurt, Meryem Toraman
    Peker, Ilkay
    Arisu, Hacer Deniz
    Bala, Oya
    Altunkaynak, Buelent
    LASERS IN MEDICAL SCIENCE, 2008, 23 (03) : 307 - 312
  • [6] Occlusal caries detection:conventional diagnosis vs laser fluorescence system.
    Dall'Orologio, GD
    Lorenzi, R
    Anselmi, M
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A90 - A90
  • [7] Validity of a laser fluorescence system (DIAGNOdent) for detection of occlusal caries in third molars:: an in vitro study
    Baseren, NM
    Gokalp, S
    JOURNAL OF ORAL REHABILITATION, 2003, 30 (12) : 1190 - 1194
  • [8] Comparison between visual examination and a laser fluorescence system for in vivo diagnosis of occlusal caries
    Sheehy, EC
    Brailsford, SR
    Kidd, EAM
    Beighton, D
    Zoitopoulos, L
    CARIES RESEARCH, 2001, 35 (06) : 421 - 426
  • [9] In vivo study of diode laser diagnosis of occlusal caries
    Costa, AM
    Bezerra, ACB
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B44 - B44
  • [10] Quantitative LASER fluorescence and primary occlusal caries diagnoses.
    Liberatore, A
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A90 - A90