Factors Associated With the Stability of Mini-Implants for Orthodontic Anchorage: A Study of 414 Samples in Taiwan

被引:83
|
作者
Wu, Tzu-Ying [2 ,4 ]
Kuang, Shou-Hsin [2 ,4 ]
Wu, Cheng-Hsien [1 ,3 ]
机构
[1] Taipei Vet Gen Hosp, Dept Stomatol, Sect Oral & Maxillofacial Surg, Taipei 11217, Taiwan
[2] Taipei Vet Gen Hosp, Dept Stomatol, Sect Orthodont & Pediat Dent, Taipei 11217, Taiwan
[3] Natl Yang Ming Univ, Sch Dent, Sect Oral & Maxillofacial Surg, Taipei 11217, Taiwan
[4] Natl Yang Ming Univ, Sch Dent, Sect Orthodont & Pediat Dent, Taipei 11217, Taiwan
关键词
BONE; INJURY;
D O I
10.1016/j.joms.2009.04.015
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To evaluate failure rates and factors associated with the stability of mini-implants used for orthodontic anchorage. Patients and Methods: We enrolled 166 patients (35 male patients and 131 female patients) who had consecutively received mini-implants for orthodontic anchorage at the Section of Orthodontics and Pediatric Dentistry, Taipei Veterans General Hospital (Taipei, Taiwan) from January 2001 to December 2006. A total of 414 mini-implants with diameters ranging from 1.2 to 2.0 mm were evaluated. Clinical variables for analysis were divided into host-related and implant-related factors. Mini-implants that could be maintained for orthodontic anchorage for more than 6 months were considered to be successful. Statistical analysis was used to evaluate the failure rate in our study cohort and to identify possible associated factors. Results: The overall failure rate was 10.1% (42 of 414 screws) with orthodontic force loading for more than 6 months. Most failures were due to loosening and occurred within the first 2 weeks. Differences in overall failure rates for the maxilla and mandible (9.3% and 16.3%, respectively) were not statistically significant. A lower failure rate was found for the maxilla with implant diameters equal to or less than 1.4 nun (P = .036). The left side had a lower failure rate than the right (6.7% vs 13.9%, P = .019). Length and type of mini-implants, age, and gender were not associated with mini-implant failure. Conclusions: Use of mini-implants for anchorage is reliable. In our study the overall success rate was 89.9%. Careful diameter selection for different locations is essential. In the maxilla an implant diameter equal to or less than 1.4 mm is recommended. In the mandible an implant diameter larger than 1.4 mm is suggested for better orthodontic anchorage. Hygienic care of implantation sites should also be emphasized for long-term success of mini-implant anchorage. (C) 2009 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 67:1595-1599, 2009
引用
收藏
页码:1595 / 1599
页数:5
相关论文
共 50 条
  • [1] Revisiting the stability of mini-implants used for orthodontic anchorage
    Yao, Chung-Chen Jane
    Chang, Hao-Hueng
    Chang, Jenny Zwei-Chieng
    Lai, Hsiang-Hua
    Lu, Shao-Chun
    Chen, Yi-Jane
    JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2015, 114 (11) : 1122 - 1128
  • [2] A prospective study of the risk factors associated with failure of mini-implants used for orthodontic anchorage
    Cheng, SJ
    Tseng, IY
    Lee, JJ
    Kok, SH
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2004, 19 (01) : 100 - 106
  • [3] The application of mini-implants for orthodontic anchorage
    Tseng, Y. -C.
    Hsieh, C. -H.
    Chen, C. -H.
    Shen, Y. -S.
    Huang, I. -Y.
    Chen, C. -M.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2006, 35 (08) : 704 - 707
  • [4] Mini-implants for direct or indirect orthodontic anchorageQuestion: What factors effect the use of mini-implants for direct or indirect orthodontic anchorage?
    Yijin Ren
    Evidence-Based Dentistry, 2009, 10 (4) : 113 - 113
  • [5] An in vitro study of factors affecting the primary stability of orthodontic mini-implants
    Holm, Lindsy
    Cunningham, Susan J.
    Petrie, Aviva
    Cousley, Richard R. J.
    ANGLE ORTHODONTIST, 2012, 82 (06) : 1022 - 1028
  • [6] Comparative Study of Mini-implants versus Standard Implants in Orthodontic Anchorage for Space Closure
    Sahoo, Sanjay Kumar
    Chekka, Manjunath
    Chawla, Riddhi
    Naimatullah, Mohammed Nehal
    Misra, K. Kumar
    Kandikatla, Pradeep
    Prashant, M. C.
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2024, 16 : S2458 - S2460
  • [7] Factors affecting the long-term stability of orthodontic mini-implants
    Turpin
    Motoyoshi, Mitsuru
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 137 (05) : 588.e1 - 588.e5
  • [8] Finite element simulations of the loading of mini-implants for orthodontic anchorage.
    Bourauel, C.
    Billen, S.
    Kawarizadeh, A.
    Bumann, A.
    Jaeger, A.
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : B312 - B312
  • [10] Effects of size and insertion angle of orthodontic mini-implants on skeletal anchorage
    Tatli, Ufuk
    Alraawi, Mohammed
    Toroglu, Mustafa Serdar
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2019, 156 (02) : 220 - 228