被引:12
|
作者
Werner, Christian [1 ,2 ]
Chalvatzaki, Georgia [3 ]
Papageorgiou, Xanthi S. [3 ]
Tzafestas, Costas S. [3 ]
Bauer, Juergen M. [1 ,2 ]
Hauer, Klaus [2 ]
机构
[1] Heidelberg Univ, Ctr Geriatr Med, Heidelberg, Germany
[2] Heidelberg Univ, Agaples Bethanien Hosp Heidelberg, Geriatr Ctr, Rohrbacher Str 149, D-69126 Heidelberg, Germany
[3] Natl Tech Univ Athens, Sch Elect & Comp Engn, Athens, Greece
基金
欧盟第七框架计划;
关键词
Smart walker; gait analysis; elderly; validity; assistive devices; ASSISTANCE; PRECISION; ROLLATOR;
D O I
10.1177/0269215519852143
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: To assess the concurrent validity of a smart walker-integrated gait analysis system with the GAITRite (R) system for measuring spatiotemporal gait parameters in potential users of the smart walker. Design: Criterion standard validation study. Setting: Research laboratory in a geriatric hospital. Participants: Twenty-five older adults (> 65 years) with gait impairments (habitual rollator use and/or gait speed <0.6 m/s) and no severe cognitive impairment (Mini-Mental State Examination > 17). Main measures: Stride, swing and stance time; stride length; and gait speed were simultaneously recorded using the smart walker-integrated gait analysis system and the GAITRite system while participants walked along a 7.8-m walkway with the smart walker. Concurrent criterion-related validity was assessed using the Bland-Altman method, percentage errors (acceptable if <30%), and intraclass correlation coefficients for consistency (ICC3,1) and absolute agreement (ICC2,1). Results: Bias for stride, swing and stance time ranged from -0.04 to 0.04 seconds, with acceptable percentage errors (8.7%-23.0%). Stride length and gait speed showed higher bias (mean(bias) (SD) = 0.20 (0.11) m; 0.19 (0.13) m/s) and not acceptable percentage errors (31.3%-42.3%). Limits of agreement were considerably narrower for temporal than for spatial-related gait parameters. All gait parameters showed good-to-excellent consistency (ICC3,1 = 0.72-0.97). Absolute agreement was good-to-excellent for temporal (ICC2,1 = 0.72-0.97) but only poor-to-fair for spatial-related gait parameters (ICC2,1 = 0.37-0.52). Conclusion: The smart walker-integrated gait analysis system has good concurrent validity with the GAITRite system for measuring temporal but not spatial-related gait parameters in potential end-users of the smart walker. Stride length and gait speed can be measured with good consistency, but with only limited absolute accuracy.
引用
收藏
页码:1682 / 1687
页数:6
相关论文
共 50 条
  • [21] Concurrent validity of the ZeroWire® footswitch system for the measurement of temporal gait parameters
    Pradeau, C.
    Sturbois-Nachef, N.
    Allart, E.
    GAIT & POSTURE, 2020, 82 : 133 - 137
  • [22] A Smart Socks System for Running Gait Analysis
    Eizentals, Peteris
    Katashev, Alexei
    Oks, Alexander
    ICSPORTS: PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON SPORT SCIENCES RESEARCH AND TECHNOLOGY SUPPORT, 2019, : 47 - 54
  • [23] Gait analysis by using Smart Socks system
    Eizentals, P.
    Katashev, A.
    Oks, A.
    AEGEAN INTERNATIONAL TEXTILE AND ADVANCED ENGINEERING CONFERENCE (AITAE 2018), 2018, 459
  • [24] Gait analysis and tailored exercise prescription in older adults
    Kressig, RW
    Beauchet, O
    ZEITSCHRIFT FUR GERONTOLOGIE UND GERIATRIE, 2004, 37 (01): : 15 - 19
  • [25] Analysis of Gait Signature Patterns of Older Adults.
    Krotish, D. E.
    Mitchell, P.
    Shin, Y.
    Hirth, V.
    JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 2010, 58 : 69 - 69
  • [26] Assessing the utility of smart mobile phones in gait pattern analysis
    Mingjing Yang
    Huiru Zheng
    Haiying Wang
    Sally McClean
    Nigel Harris
    Health and Technology, 2012, 2 (1) : 81 - 88
  • [27] Assessing the utility of smart mobile phones in gait pattern analysis
    Yang, Mingjing
    Zheng, Huiru
    Wang, Haiying
    McClean, Sally
    Harris, Nigel
    HEALTH AND TECHNOLOGY, 2012, 2 (01) : 81 - 88
  • [28] Design and initial validity study of perception-empathy biofeedback system for gait training in older adults
    Yasuda, Kazuhiro
    Saichi, Kenta
    Iwata, Hiroyasu
    2018 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS (SMC), 2018, : 1530 - 1534
  • [29] The Reliability and Validity of Measures of Gait Variability in Community-Dwelling Older Adults
    Brach, Jennifer S.
    Perera, Subashan
    Studenski, Stephanie
    Newman, Anne B.
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2008, 89 (12): : 2293 - 2296
  • [30] Development of a Data Base to Gait Analysis and Data Organization in ASBGo Smart Walker
    Caetano, Ines
    Alves, Joana
    Varzim, Ricardo
    Santos, Cristina P.
    2017 IEEE 5TH PORTUGUESE MEETING ON BIOENGINEERING (ENBENG), 2017,